Search icon

POWER LEE INC.

Company Details

Name: POWER LEE INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Inactive
Date of registration: 26 Jun 2009 (16 years ago)
Date of dissolution: 03 Jul 2019
Entity Number: 3827043
ZIP code: 10002
County: New York
Place of Formation: New York
Address: 191 MADISON ST, APT 4C, NEW YORK, NY, United States, 10002

Contact Details

Phone +1 917-662-2495

Phone +1 212-475-8308

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 191 MADISON ST, APT 4C, NEW YORK, NY, United States, 10002

Agent

Name Role Address
ZHEN QIN LI Agent 191 MADISON STREET, APT 4C, NEW YORK, NY, 10002

Chief Executive Officer

Name Role Address
ZHEN QIN LI Chief Executive Officer 191 MADISON ST, APT 4C, NEW YORK, NY, United States, 10002

Licenses

Number Status Type Date End date
1372053-DCA Inactive Business 2010-09-23 2000-12-31
1364987-DCA Inactive Business 2010-08-03 2015-02-28

History

Start date End date Type Value
2009-06-26 2011-07-21 Address 191 MADISON STREET, #4C, NEW YORK, NY, 10002, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
190703000068 2019-07-03 CERTIFICATE OF DISSOLUTION 2019-07-03
110721002885 2011-07-21 BIENNIAL STATEMENT 2011-06-01
100928000257 2010-09-28 CERTIFICATE OF CHANGE 2010-09-28
090626000192 2009-06-26 CERTIFICATE OF INCORPORATION 2009-06-26

Fine And Fees

Fee Sequence Id Fee type Status Date Amount Description
1025811 CNV_TFEE INVOICED 2013-05-06 7.46999979019165 WT and WH - Transaction Fee
1025812 TRUSTFUNDHIC INVOICED 2013-05-06 200 Home Improvement Contractor Trust Fund Enrollment Fee
1055362 RENEWAL INVOICED 2013-05-06 100 Home Improvement Contractor License Renewal Fee
1025813 TRUSTFUNDHIC INVOICED 2011-06-02 200 Home Improvement Contractor Trust Fund Enrollment Fee
1055363 RENEWAL INVOICED 2011-06-02 100 Home Improvement Contractor License Renewal Fee
1025816 CNV_MS INVOICED 2010-09-23 15 Miscellaneous Fee
1025814 LICENSE INVOICED 2010-08-03 50 Home Improvement Contractor License Fee
1025815 TRUSTFUNDHIC INVOICED 2010-08-03 200 Home Improvement Contractor Trust Fund Enrollment Fee

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339639957 0215000 2014-03-19 457 39TH STREET, BROOKLYN, NY, 11232
Inspection Type Unprog Rel
Scope Complete
Safety/Health Safety
Close Conference 2014-03-19
Emphasis L: FALL
Case Closed 2016-06-13

Related Activity

Type Inspection
Activity Nr 963837
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2014-03-26
Current Penalty 1550.0
Initial Penalty 2800.0
Contest Date 2016-01-26
Final Order 2016-05-13
Nr Instances 5
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports. Location: 457 39th Street Brooklyn, NY. On or about: 03/19/14 a) Employees were laying cinder blocks from a tubular welded frame scaffold that was not fully planked. The employees were exposed to potential fall hazards of up to 13 feet to the ground below.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2014-03-26
Current Penalty 1550.0
Initial Penalty 2800.0
Contest Date 2016-01-26
Final Order 2016-05-13
Nr Instances 5
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access. Location: 457 39th Street Brooklyn, NY. On or about: 03/19/14 a) Employees were working from a tubular welded frame scaffold that did not have means of access. Employees climbed frames and crossbraces to get to work platform.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2014-03-26
Current Penalty 2150.0
Initial Penalty 2800.0
Contest Date 2016-01-26
Final Order 2016-05-13
Nr Instances 5
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. Location: 1 Woodrow Court Brooklyn, NY. On or about 11/06/13 a) Employees were laying cement blocks from a tubular welded frame scaffold that was not provided with any fall protection system. The employees were exposed to a potential fall hazard of up to 13 feet to the ground below.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2014-03-26
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2016-01-26
Final Order 2016-05-13
Nr Instances 1
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. Location: 457 39th Street Brooklyn, NY. On or about: 03/19/14 a) Employees were not trained to recognize hazards associated with the type of scaffold being used. The employees were not provided with proper fall protection system while exposed to a potential fall of 13 feet to the ground below.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2014-03-26
Current Penalty 2150.0
Initial Penalty 2800.0
Contest Date 2016-01-26
Final Order 2016-05-13
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. Location: 457 39th Street Brooklyn, NY. On or about: 03/19/14 a) Three employees were workinkg on a new floor deck without fall protection while exposed to a potential fall hazard up to 20 feet to the ground below.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2014-03-26
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2016-01-26
Final Order 2016-05-13
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards. Location: 457 39th Street Brooklyn, NY. On or about: 03/19/14 a) Employees were not trained to recognize fall hazards. Three employees were working by the edge of a new floor deck without any fall protection while exposed to potential fall hazars of approximately 20 feet to ground below.
Citation ID 01005A
Citaton Type Serious
Standard Cited 19261052 C01
Issuance Date 2014-03-26
Current Penalty 2150.0
Initial Penalty 2800.0
Contest Date 2016-01-26
Final Order 2016-05-13
Nr Instances 4
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail and one stairrail system along each unprotected side or edge. Location: 457 39th Street Brooklyn, NY. On or about: 03/19/14 a) Employees were using unprotected stairways as means of access while exposed to potential fall hazards up to 15 feet to the ground below.
Citation ID 01005B
Citaton Type Serious
Standard Cited 19261052 B01
Issuance Date 2014-03-26
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2016-01-26
Final Order 2016-05-13
Nr Instances 4
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(b)(1): Where the treads and/or landings of pan stairs were to be filled in with concrete or other material at a later date, foot traffic was not prohibited on the stairway. Location: 457 39th Street Brooklyn, NY. On or about: 03/19/14 a) The stairs used by the employees as means of access did not have the treads filled.
Citation ID 01006
Citaton Type Serious
Standard Cited 19260701 B
Issuance Date 2014-03-26
Current Penalty 2150.0
Initial Penalty 2800.0
Contest Date 2016-01-26
Final Order 2016-05-13
Nr Instances 10
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall or come against, was not guarded to eliminate the hazard of impalement. Location: 457 39th Street Brooklyn, NY. On or about: 03/19/14 a) Employees were working above and next to unprotected steel rebar.
Citation ID 02001
Citaton Type Other
Standard Cited 19101200 E01
Issuance Date 2014-03-26
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2016-01-26
Final Order 2016-05-13
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, material safety data sheets, and employee information and training will be met, and which also includes the following: Location: 457 39th Street Brooklyn, NY. On or about: 03/19/14 a) The employer did not implement and develop a written Hazard Communication Program for each employee exposed/using chemicals such as gasoline, cement and joint compound.
Citation ID 02002
Citaton Type Other
Standard Cited 19101200 G01
Issuance Date 2014-03-26
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2016-01-26
Final Order 2016-05-13
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(g)(1): Employers shall have a material safety data sheet in the workplace for each hazardous chemical which they use. Location: 457 39th Street Brooklyn, NY. On or about: 03/19/14 a) Employer did not maintain the required MSDS information sheets to his employees for on site reference of the chemicals on site, including gasoline, joint compound and Portland cement.
Citation ID 02003
Citaton Type Other
Standard Cited 19101200 H01
Issuance Date 2014-03-26
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2016-01-26
Final Order 2016-05-13
Nr Instances 1
Nr Exposed 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new physical or health hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and material safety data sheets. Location: 457 39th Street Brooklyn, NY. On or about: 03/19/14 a)The employer did not instruct and inform employees of the hazards for each employee exposed/using chemicals such as gasoline, portland cement and joint compound.