Search icon

A AND D DYNAMIC DESIGNS, INC.

Company Details

Name: A AND D DYNAMIC DESIGNS, INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 02 Sep 2009 (16 years ago)
Entity Number: 3851744
ZIP code: 11778
County: Suffolk
Place of Formation: New York
Address: 135 rocky point landing rd, ROCKY POINT, NY, United States, 11778

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

Chief Executive Officer

Name Role Address
DOMINIC J. LASURDO Chief Executive Officer 135 ROCKY POINT LANDING RD, ROCKY POINT, NY, United States, 11778

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 135 rocky point landing rd, ROCKY POINT, NY, United States, 11778

History

Start date End date Type Value
2011-09-29 2016-08-15 Address 7 MEADOW LANE, ROCKY POINT, NY, 11778, USA (Type of address: Chief Executive Officer)
2011-09-29 2016-08-15 Address 7 MEADOW LANE, ROCKY POINT, NY, 11778, USA (Type of address: Principal Executive Office)
2009-09-02 2016-08-12 Address 7 MEADOW LANE, ROCKY POINT, NY, 11778, USA (Type of address: Service of Process)
2009-09-02 2024-09-25 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0

Filings

Filing Number Date Filed Type Effective Date
220720002118 2022-07-20 BIENNIAL STATEMENT 2021-09-01
160815006046 2016-08-15 BIENNIAL STATEMENT 2015-09-01
160812000328 2016-08-12 CERTIFICATE OF CHANGE 2016-08-12
130911006243 2013-09-11 BIENNIAL STATEMENT 2013-09-01
110929002547 2011-09-29 BIENNIAL STATEMENT 2011-09-01
090902000014 2009-09-02 CERTIFICATE OF INCORPORATION 2009-09-02

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346804586 0214700 2023-06-29 135 ROCKY POINT LANDING, ROCKY POINT, NY, 11778
Inspection Type Complaint
Scope Complete
Safety/Health Health
Close Conference 2023-06-29
Emphasis N: HEATNEP, N: RCS-NEP

Related Activity

Type Complaint
Activity Nr 2048003
Health Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100134 C
Issuance Date 2023-12-20
Abatement Due Date 2024-01-10
Current Penalty 1000.0
Initial Penalty 2679.0
Contest Date 2024-01-17
Final Order 2024-08-12
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c):The employer did not develop and implement a written respiratory protection program with required worksite-specific procedures and elements for required respirator use: a) At 100 Thompson St, Port Jefferson, A and D Dynamic Designs did not develop and implement a respiratory protection program for employees wearing negative pressure respirators. On or about 6/29/2023 Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100134 E01
Issuance Date 2023-12-20
Abatement Due Date 2024-01-10
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2024-01-17
Final Order 2024-08-12
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) At 100 Thompson St, Port Jefferson, A and D Dynamic Designs did not provide medical evaluations for employees wearing negative pressure respirators. On or about 6/29/2023 Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19100134 F01
Issuance Date 2023-12-20
Abatement Due Date 2024-01-10
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2024-01-17
Final Order 2024-08-12
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(f)(1): The employer did not ensure that employees using a tight-fitting facepiece respirator pass an appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT) as stated in this paragraph. a) At 100 Thompson St, Port Jefferson, A and D Dynamic Designs did not fit test employees wearing negative pressure respirators. On or about 6/29/2023 Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01001D
Citaton Type Serious
Standard Cited 19100134 K03
Issuance Date 2023-12-20
Abatement Due Date 2024-01-10
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2024-01-17
Final Order 2024-08-12
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(k)(3): Training was not provided prior to requiring employees to use a respirator in the workplace: a) At 100 Thompson St, Port Jefferson, A and D Dynamic Designs did not train employees wearing negative pressure respirators. On or about 6/29/2023 Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19261153 C01
Issuance Date 2023-12-20
Abatement Due Date 2024-01-03
Current Penalty 3000.0
Initial Penalty 3349.0
Contest Date 2024-01-17
Final Order 2024-08-12
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1153(c)(1): For each employee engaged in a task identified on Table 1, the employer did not fully and properly implement the engineering controls, work practices, and respiratory protection specified for the task on Table 1. a) At 100 Thompson St, Port Jefferson, A and D Dynamic Designs. Employees were cutting stone pavers with a HILTI DSH 700X a gasoline-powered cut-off saw. Table 1-Specified Exposure Control Methods When Working with Materials Containing Crystalline Silica specifies the use of saw equipped with integrated water delivery system that continuously feeds water to the blade. Water was not utilized to control silica dust exposure to employees. On or about 6/29/2023. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19261153 G01
Issuance Date 2023-12-20
Abatement Due Date 2024-01-03
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2024-01-17
Final Order 2024-08-12
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1153(g)(1):The employer did not establish and implement a written exposure control plan: a) At 100 Thompson St, Port Jefferson, A and D Dynamic Designs did not develop and implement a silica exposure control plan for employees exposed to silica when cutting and installing pavers. On or about 6/29/2023. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19261153 I02 I A
Issuance Date 2023-12-20
Abatement Due Date 2024-01-03
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2024-01-17
Final Order 2024-08-12
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1153(i)(2)(i)(A): The employer did not ensure that each employee covered by this section could demonstrate knowledge and understanding of the health hazards associated with exposure to respirable crystalline silica: a) At 100 Thompson St, Port Jefferson, A and D Dynamic Designs did not train employees of the silica exposure hazard created when cutting concrete pavers dry. On or about 6/29/2023. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19101200 E01
Issuance Date 2023-12-20
Abatement Due Date 2024-01-03
Current Penalty 0.0
Initial Penalty 2679.0
Contest Date 2024-01-17
Final Order 2024-08-12
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1):The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a)At the workplace A and D Designs employees use and are exposed to hazardous chemicals such as gasoline and silica. On or about 6/29/2023. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19101200 G01
Issuance Date 2023-12-20
Abatement Due Date 2024-01-03
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2024-01-17
Final Order 2024-08-12
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use. At the workplace A and D Dynamic Designs, Employees use gasoline to operate Hilti gas powered concrete saw and generate silica dust when pavers are cut. Safety Data Sheets were not readily available. On or about 6/29/2023. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01003C
Citaton Type Serious
Standard Cited 19101200 H01
Issuance Date 2023-12-20
Abatement Due Date 2024-01-03
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2024-01-17
Final Order 2024-08-12
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: At the workplace A and D Dynamic Designs, Employees use gasoline to operate Hilti gas powered concrete saw and generate silica dust when pavers are cut. Employees were not trained on hazardous chemicals in the work area. On or about 6/29/2023. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
4914877808 2020-05-29 0235 PPP 387 Locust Drive, Rocky Point, NY, 11778-9267
Loan Status Date 2021-09-25
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 15760
Loan Approval Amount (current) 15760
Undisbursed Amount 0
Franchise Name -
Lender Location ID 456756
Servicing Lender Name Cross River Bank
Servicing Lender Address 885 Teaneck Rd, TEANECK, NJ, 07666-4546
Rural or Urban Indicator U
Hubzone N
LMI Y
Business Age Description Unanswered
Project Address Rocky Point, SUFFOLK, NY, 11778-9267
Project Congressional District NY-01
Number of Employees 4
NAICS code 236115
Borrower Race Unanswered
Borrower Ethnicity Not Hispanic or Latino
Business Type Subchapter S Corporation
Originating Lender ID 456756
Originating Lender Name Cross River Bank
Originating Lender Address TEANECK, NJ
Gender Male Owned
Veteran Non-Veteran
Forgiveness Amount 15946.1
Forgiveness Paid Date 2021-08-09
9006488301 2021-01-30 0235 PPS 387 Locust Dr, Rocky Point, NY, 11778-9267
Loan Status Date 2021-09-25
Loan Status Paid in Full
Loan Maturity in Months 60
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 15720
Loan Approval Amount (current) 15720
Undisbursed Amount 0
Franchise Name -
Lender Location ID 456756
Servicing Lender Name Cross River Bank
Servicing Lender Address 885 Teaneck Rd, TEANECK, NJ, 07666-4546
Rural or Urban Indicator U
Hubzone N
LMI Y
Business Age Description Existing or more than 2 years old
Project Address Rocky Point, SUFFOLK, NY, 11778-9267
Project Congressional District NY-01
Number of Employees 4
NAICS code 236115
Borrower Race Unanswered
Borrower Ethnicity Not Hispanic or Latino
Business Type Subchapter S Corporation
Originating Lender ID 456756
Originating Lender Name Cross River Bank
Originating Lender Address TEANECK, NJ
Gender Male Owned
Veteran Non-Veteran
Forgiveness Amount 15799.68
Forgiveness Paid Date 2021-08-06

Motor Carrier Census

USDOT Number Carrier Operation MCS-150 Form Date MCS-150 Mileage MCS-150 Year Power Units Drivers Operation Classification
1982551 Intrastate Non-Hazmat 2024-02-21 12000 2020 2 1 Private(Property)
Legal Name A AND D DYNAMIC DESIGNS INC
DBA Name -
Physical Address 135 ROCKY POINT LANDING RD, ROCKY POINT, NY, 11778, US
Mailing Address 135 ROCKY POINT LANDING RD, ROCKY POINT, NY, 11778, US
Phone (631) 848-0412
Fax -
E-mail DLDYNAMIC@YAHOO.COM

Safety Measurement System - All Transportation

Total Number of Inspections for the measurement period (24 months) 2
Driver Fitness BASIC Serious Violation Indicator No
Vehicle Maintenance BASIC Acute/Critical Indicator No
Unsafe Driving BASIC Acute/Critical Indicator No
Driver Fitness BASIC Roadside Performance measure value .25
Hours-of-Service (HOS) Compliance BASIC Roadside Performance measure value 0
Total Number of Driver Inspections for the measurment period 2
Vehicle Maintenance BASIC Roadside Performance measure value 4.5
Total Number of Vehicle Inspections for the measurement period 2
Controlled Substances and Alcohol BASIC Roadside Performance measure value 0
Unsafe Driving BASIC Roadside Performance Measure Value 0
Number of inspections with at least one Driver Fitness BASIC violation 1
Number of inspections with at least one Hours-of-Service BASIC violation 0
Total Number of Driver Inspections containing at least one Driver Out-of-Service Violation 0
Number of inspections with at least one Vehicle Maintenance BASIC violation 1
Total Number of Vehicle Inspections containing at least one Vehicle Out-of-Service violation 1
Number of inspections with at least one Controlled Substances and Alcohol BASIC violation 0
Number of inspections with at least one Unsafe Driving BASIC violation 0

Inspections

Unique report number of the inspection 0L91000560
State abbreviation that indicates the state the inspector is from NY
The date of the inspection 2024-02-08
ID that indicates the level of inspection Full
State abbreviation that indicates where the inspection occurred NY
Time weight of the inspection 2
Number of Out-Of-Service violations related to Driver 0
Number of Out-Of-Service violations related to vehicle 1
Number of violations related to Hazardous Materials 0
Total number of Out-Of-Service violations 1
Total number of Out-Of-Service violations related to Hazardous Materials 0
Description of the type of the main unit STRAIGHT TRUCK
Description of the make of the main unit FORD
License plate of the main unit 63175JZ
License state of the main unit NY
Vehicle Identification Number of the main unit 1FDAF56P97EA91508
Unsafe Driving BASIC inspection Y
Hours-of-Service Compliance BASIC inspection Y
Driver Fitness BASIC inspection Y
Controlled Substances/Alcohol BASIC inspection Y
Vehicle Maintenance BASIC inspection Y
Total number of BASIC violations 6
Number of Unsafe Driving BASIC violations 0
Number of Hours-of-Service Compliance BASIC violations 0
Number of Driver Fitness BASIC violations 1
Number of Controlled Substances/Alcohol BASIC violations 0
Number of Vehicle Maintenance BASIC violations 5
Number of Hazardous Materials Compliance BASIC violations 0
Unique report number of the inspection SPB3000060
State abbreviation that indicates the state the inspector is from NY
The date of the inspection 2024-11-12
ID that indicates the level of inspection Full
State abbreviation that indicates where the inspection occurred NY
Time weight of the inspection 3
Number of Out-Of-Service violations related to Driver 0
Number of Out-Of-Service violations related to vehicle 0
Number of violations related to Hazardous Materials 0
Total number of Out-Of-Service violations 0
Total number of Out-Of-Service violations related to Hazardous Materials 0
Description of the type of the main unit STRAIGHT TRUCK
Description of the make of the main unit FORD
License plate of the main unit 62950ML
License state of the main unit NY
Vehicle Identification Number of the main unit 1FD0W5HT3JEC48866
Unsafe Driving BASIC inspection Y
Hours-of-Service Compliance BASIC inspection Y
Driver Fitness BASIC inspection Y
Controlled Substances/Alcohol BASIC inspection Y
Vehicle Maintenance BASIC inspection Y
Total number of BASIC violations 0
Number of Unsafe Driving BASIC violations 0
Number of Hours-of-Service Compliance BASIC violations 0
Number of Driver Fitness BASIC violations 0
Number of Controlled Substances/Alcohol BASIC violations 0
Number of Vehicle Maintenance BASIC violations 0
Number of Hazardous Materials Compliance BASIC violations 0

Violations

The date of the inspection 2024-02-08
Code of the violation 39617CPI
Name of the BASIC Vehicle Maintenance
The violation is identified as Out-Of-Service violation N
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation 0
The severity weight that is assigned to a violation 4
The time weight that is assigned to a violation 2
The description of a violation Operating a CMV without documentation of a periodic inspection
The description of the violation group Inspection Reports
The unit a violation is cited against Vehicle main unit
The date of the inspection 2024-02-08
Code of the violation 3939ALIL
Name of the BASIC Vehicle Maintenance
The violation is identified as Out-Of-Service violation N
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation 0
The severity weight that is assigned to a violation 2
The time weight that is assigned to a violation 2
The description of a violation Lighting - Identification lamp(s) inoperative
The description of the violation group Clearance Identification Lamps/Other
The unit a violation is cited against Vehicle main unit
The date of the inspection 2024-02-08
Code of the violation 39395A3
Name of the BASIC Vehicle Maintenance
The violation is identified as Out-Of-Service violation N
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation 0
The severity weight that is assigned to a violation 2
The time weight that is assigned to a violation 2
The description of a violation Emergency Equipment - Fire Extinguishers - no visual indicator
The description of the violation group Emergency Equipment
The unit a violation is cited against Vehicle main unit
The date of the inspection 2024-02-08
Code of the violation 39378AWS
Name of the BASIC Vehicle Maintenance
The violation is identified as Out-Of-Service violation N
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation 0
The severity weight that is assigned to a violation 1
The time weight that is assigned to a violation 2
The description of a violation Washers - Inoperative washing system.
The description of the violation group Windshield/ Glass/ Markings
The unit a violation is cited against Vehicle main unit
The date of the inspection 2024-02-08
Code of the violation 393100BC
Name of the BASIC Vehicle Maintenance
The violation is identified as Out-Of-Service violation Y
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation 2
The severity weight that is assigned to a violation 7
The time weight that is assigned to a violation 2
The description of a violation Cargo - Cargo not secured to prevent leaking/spilling/blowing/falling from CMV
The description of the violation group Improper Load Securement
The unit a violation is cited against Vehicle main unit
The date of the inspection 2024-02-08
Code of the violation 39141AMCPC
Name of the BASIC Driver Fitness
The violation is identified as Out-Of-Service violation N
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation 0
The severity weight that is assigned to a violation 1
The time weight that is assigned to a violation 2
The description of a violation Medical (Certificate) - Operating a property-carrying vehicle without possessing a valid medical certificate
The description of the violation group Medical Certificate
The unit a violation is cited against Driver

Date of last update: 27 Mar 2025

Sources: New York Secretary of State