Search icon

BUCKY LAINHART CONSTRUCTION, LLC

Company Details

Name: BUCKY LAINHART CONSTRUCTION, LLC
Jurisdiction: New York
Legal type: DOMESTIC LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 21 Oct 2009 (16 years ago)
Entity Number: 3869658
ZIP code: 14433
County: Onondaga
Place of Formation: New York
Address: 2328 NOBLE RD, CLYDE, NY, United States, 14433

DOS Process Agent

Name Role Address
BUCKY LAINHART CONSTRUCTION, LLC DOS Process Agent 2328 NOBLE RD, CLYDE, NY, United States, 14433

History

Start date End date Type Value
2011-11-09 2013-10-17 Address 2328 NOBLE RD, CLYDE, NY, 11433, USA (Type of address: Service of Process)
2009-10-21 2011-11-09 Address HISCOCK & BARCLAY LLP, ONE PARK PL 300 S STATE STREET, SYRACUSE, NY, 13202, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
171012006229 2017-10-12 BIENNIAL STATEMENT 2017-10-01
151020006002 2015-10-20 BIENNIAL STATEMENT 2015-10-01
131017006595 2013-10-17 BIENNIAL STATEMENT 2013-10-01
111109002457 2011-11-09 BIENNIAL STATEMENT 2011-10-01
091231000972 2009-12-31 CERTIFICATE OF PUBLICATION 2009-12-31
091021000205 2009-10-21 ARTICLES OF ORGANIZATION 2009-10-21

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341481836 0215800 2016-05-18 9090 DESTINY USA DRIVE, SYRACUSE, NY, 13204
Inspection Type Referral
Scope Partial
Safety/Health Health
Close Conference 2016-11-15
Emphasis N: SILICA
Case Closed 2017-09-22

Related Activity

Type Referral
Activity Nr 1092566
Health Yes
Type Inspection
Activity Nr 1153485
Health Yes
Type Inspection
Activity Nr 1146170
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260021 B03
Issuance Date 2016-11-18
Abatement Due Date 2017-03-08
Current Penalty 2494.0
Initial Penalty 4988.0
Contest Date 2016-12-13
Final Order 2017-04-17
Nr Instances 1
Nr Exposed 17
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.21(b)(3): Employees required to handle or use poisons, caustics, and other harmful substances were not instructed regarding the safe handling and use, and were not made aware of the potential hazards, personal hygiene, and personal protective measures required: a) At the Destiny Mall, Syracuse worksite, on or about 5/19/2016: The laborers were exposed to caustic wet cement and airborne silica dust and were not instructed about the skin and respiratory hazards of the work; where the dust encountered during jackhammering was not described as hazardous silica containing dust. Abatement documentation must be submitted.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260055 A
Issuance Date 2016-11-18
Abatement Due Date 2017-03-08
Current Penalty 0.0
Initial Penalty 4988.0
Contest Date 2016-12-13
Final Order 2017-04-17
Nr Instances 1
Nr Exposed 17
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.55(a): Exposure of employees to inhalation, ingestion, skin absorption, or contact with any material or substance at a concentration above those specified in the "Threshold Limit Values of Airborne Contaminants for 1970" of the American Conference of Governmental Industrial Hygienists, shall be avoided. See Appendix A to this section. (a) At the Destiny Mall, Syracuse NY on or about 5/19/2016: The jackhammer operator was exposed to crystalline quartz silica dust at the 8 hour time weighted average of 1.79 mg/m3, which was 1.29 times the Permissible Exposure Limit (PEL) of 1.39 mg/m3. Sampling was conducted for 465 minutes and a zero increment was included for the remaining 15 minutes. Abatement documentation must be submitted.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260055 B
Issuance Date 2016-11-18
Abatement Due Date 2017-03-08
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2016-12-13
Final Order 2017-04-17
Nr Instances 1
Nr Exposed 17
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.55(b): Feasible administrative or engineering controls were not implemented to reduce employee exposure(s): (a) At the Destiny Mall garage renovation, Syracuse NY on or about 5/19/2016: The jackhammer operator was exposed to crystalline quartz silica dust at the 8 hour time weighted average of 1.79 mg/m3, which was 1.29 times the Permissible Exposure Limit (PEL) of 1.39 mg/m3. The administrative or engineering controls used were inadequate and feasible controls such as effective job rotation or dust-reducing jackhammer equipment were not employed. Abatement documentation must be submitted.
Citation ID 01001D
Citaton Type Serious
Standard Cited 19100134 C01
Issuance Date 2016-11-18
Abatement Due Date 2017-03-08
Current Penalty 0.0
Initial Penalty 4988.0
Contest Date 2016-12-13
Final Order 2017-04-17
Nr Instances 1
Nr Exposed 17
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (Construction Reference 1926.103) (a) At the Destiny Mall, Syracuse worksite, on or about 5/19/2016: Where jackhammer operators were exposed to silica dust and were required to wear N-95 filtering facepiece respirators for dusty work, there was no written respiratory program established or implemented. Abatement documentation must be submitted.
Citation ID 01001E
Citaton Type Serious
Standard Cited 19100134 D01 III
Issuance Date 2016-11-18
Abatement Due Date 2017-03-08
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2016-12-13
Final Order 2017-04-17
Nr Instances 1
Nr Exposed 17
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form: (Construction Reference 1926.103) (a) At the Destiny Mall, Syracuse worksite, on or about 5/19/2016: Where jackhammer operators were exposed to silica dust and were required by Bucky Lainhart Construction to wear N-95 filtering facepiece respirators for their dusty work, the employer had not performed any employee air monitoring to determine the severity of the silica hazard created during that task. Abatement documentation must be submitted.
Citation ID 01001F
Citaton Type Serious
Standard Cited 19100134 K06
Issuance Date 2016-11-18
Abatement Due Date 2017-03-08
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2016-12-13
Final Order 2017-04-17
Nr Instances 1
Nr Exposed 17
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer: (Construction Reference 1926.103) (a) At the Destiny Mall, Syracuse worksite, on or about 5/19/2016: Where jackhammer operators wore N-95 filtering facepiece respirators for dusty work, the employer had not provided the information and limitations of the respirators as presented in Appendix D of the respirator standard. Abatement documentation must be submitted.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260052 B
Issuance Date 2016-11-18
Abatement Due Date 2017-03-08
Current Penalty 2494.0
Initial Penalty 4988.0
Contest Date 2016-12-13
Final Order 2017-04-17
Nr Instances 7
Nr Exposed 17
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.52(b): Employees were subjected to sound levels exceeding those listed in table D-2 of 29 CFR 1926.52 and feasible administrative or engineering controls were not utilized to reduce sound levels: (a) At the Destiny Mall, Syracuse worksite, on or about 5/19/2016: An employee performing jackhammering was exposed to continuous noise at a level of 1304% of the dose of the permissible exposure limit (PEL). The equivalent dBA for the 1304% is approximately 108.8 dBA calculated as the 8 hour time weighted sound pressure level. The OSHA permissible exposure limit is 90 dBA. Sampling was conducted for 466 minutes. A zero increment was included for the remaining 14 minutes. Administrative and engineering controls were not evaluated or implemented. (b) At the Destiny Mall, Syracuse worksite, on or about 5/19/2016: An employee performing jackhammering was exposed to continuous noise at a level of 1759% of the dose of the permissible exposure limit (PEL). The equivalent dBA for the 1759% is approximately 110.6 dBA calculated as the 8 hour time weighted sound pressure level. The OSHA permissible exposure limit is 90 dBA. Sampling was conducted for 483 minutes. Administrative and engineering controls were not evaluated or implemented. (c) At the Destiny Mall, Syracuse worksite, on or about 5/19/2016: An employee performing jackhammering was exposed to continuous noise at a level of 918% of the dose of the permissible exposure limit (PEL). The equivalent dBA for the 918% is approximately 106.7 dBA calculated as the 8 hour time weighted sound pressure level. The OSHA permissible exposure limit is 90 dBA. Sampling was conducted for 436 minutes. A zero increment was included for the remaining 44 minutes. Administrative and engineering controls were not evaluated or implemented. (d) At the Destiny Mall, Syracuse worksite, on or about 7/14/2016: An employee performing jackhammering was exposed to continuous noise at a level of 898% of the dose of the permissible exposure limit (PEL). The equivalent dBA for the 898% is approximately 108.8 dBA calculated as the 8 hour time weighted sound pressure level. The OSHA permissible exposure limit is 90 dBA. Sampling was conducted for 318 minutes. A zero increment was included for the remaining 162 minutes. Administrative and engineering controls were not evaluated or implemented. (e) At the Destiny Mall, Syracuse worksite, on or about 7/14/2016: An employee performing jackhammering was exposed to continuous noise at a level of 923% of the dose of the permissible exposure limit (PEL). The equivalent dBA for the 923% is approximately 109.0 dBA calculated as the 8 hour time weighted sound pressure level. The OSHA permissible exposure limit is 90 dBA. Sampling was conducted for 318 minutes. A zero increment was included for the remaining 162 minutes. Administrative and engineering controls were not evaluated or implemented. (f) At the Destiny Mall, Syracuse worksite, on or about 7/14/2016: An employee performing jackhammering was exposed to continuous noise at a level of 759% of the dose of the permissible exposure limit (PEL). The equivalent dBA for the 759% is approximately 107.5 dBA calculated as the 8 hour time weighted sound pressure level. The OSHA permissible exposure limit is 90 dBA. Sampling was conducted for 324 minutes. A zero increment was included for the remaining 156 minutes. Administrative and engineering controls were not evaluated or implemented. (g) At the Destiny Mall, Syracuse worksite, on or about 7/14/2016: An employee performing jackhammering was exposed to continuous noise at a level of 496% of the dose of the permissible exposure limit (PEL). The equivalent dBA for the 496% is approximately 104.5 dBA calculated as the 8 hour time weighted sound pressure level. The OSHA permissible exposure limit is 90 dBA. Sampling was conducted for 203 minutes. A zero increment was included for the remaining 277 minutes. Administrative and engineering controls were not evaluated or implemented. Abatement documentation must be submitted.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260052 D01
Issuance Date 2016-11-18
Abatement Due Date 2017-03-08
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2016-12-13
Final Order 2017-04-17
Nr Instances 7
Nr Exposed 17
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.52(d)(1): In all cases where the sound levels exceeded the values shown in Table D-2 of 29 CFR 1926.52, a continuing, effective hearing conservation program was not administered: (a) At the Destiny Mall, Syracuse worksite, on or about 5/19/2016: Where jackhammer operators were exposed to noise levels exceeding the values in Table D-2, the employer did not implement a hearing conservation program. See Citation1, Item 2a for exposure detail. Abatement documentation must be submitted.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19260101 A
Issuance Date 2016-11-18
Abatement Due Date 2017-03-08
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2016-12-13
Final Order 2017-04-17
Nr Instances 7
Nr Exposed 17
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.101(a): Ear protective devices were not provided and/or were not used when it was not feasible to reduce noise levels or duration of exposures to those specified in Table D-2, Permissible Noise Exposure, in 29 CFR 1926.52: (a) At the Destiny Mall, Syracuse worksite, on or about 5/19/2016: Where jackhammer operators were exposed to noise levels exceeding the values in Table D-2, some jackhammer operators were observed not wearing hearing protective devices when working. See Citation 1, Item 2A for exposure detail. Abatement documentation must be submitted.
341461705 0215800 2016-05-10 9090 DESTINY USA DRIVE, SYRACUSE, NY, 13204
Inspection Type Complaint
Scope Complete
Safety/Health Safety
Close Conference 2016-08-31
Case Closed 2017-01-09

Related Activity

Type Inspection
Activity Nr 1146136
Safety Yes
Type Complaint
Activity Nr 1089661
Safety Yes
Type Inspection
Activity Nr 1148183
Health Yes

Date of last update: 27 Mar 2025