Search icon

L.P.G. GENERAL CONTRACTOR INC.

Company Details

Name: L.P.G. GENERAL CONTRACTOR INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 02 Nov 2009 (15 years ago)
Entity Number: 3874115
ZIP code: 12540
County: Westchester
Place of Formation: New York
Address: 60 EMANS RD, LAGRANGEVILLE, NY, United States, 12540
Principal Address: 83 NAPOLEON STREET 2FL, NEWARK, NJ, United States, 07105

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

Chief Executive Officer

Name Role Address
SEGUNDO POMAVILLA Chief Executive Officer 60 EMANS RD, LAGRANGEVILLE, NY, United States, 12540

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 60 EMANS RD, LAGRANGEVILLE, NY, United States, 12540

History

Start date End date Type Value
2024-11-29 2024-11-29 Address 5 HAWKES AVENUE, OSSINING, NY, 10562, USA (Type of address: Chief Executive Officer)
2013-12-19 2024-11-29 Address 5 HAWKES AVENUE, OSSINING, NY, 10562, USA (Type of address: Chief Executive Officer)
2011-11-30 2013-12-19 Address 5 HAWKES AVENUE, OSSINING, NY, 10562, USA (Type of address: Chief Executive Officer)
2011-11-30 2024-11-29 Address 5 HAWKES AVENUE, OSSINING, NY, 10562, USA (Type of address: Service of Process)
2009-11-02 2011-11-30 Address 83 NAPOLEON STREET, NEWARK, NJ, 07105, USA (Type of address: Service of Process)
2009-11-02 2024-11-29 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0

Filings

Filing Number Date Filed Type Effective Date
241129001072 2024-11-29 BIENNIAL STATEMENT 2024-11-29
131219002168 2013-12-19 BIENNIAL STATEMENT 2013-11-01
111130002062 2011-11-30 BIENNIAL STATEMENT 2011-11-01
091102000430 2009-11-02 CERTIFICATE OF INCORPORATION 2009-11-02

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347143968 0216000 2023-12-05 25 BARKER ST, UNIT 86, MOUNT KISCO, NY, 10549
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2023-12-05
Emphasis N: FALL
Case Closed 2024-11-29

Related Activity

Type Complaint
Activity Nr 2109763
Safety Yes
Type Inspection
Activity Nr 1714879
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19260102 A01
Issuance Date 2024-01-30
Current Penalty 0.0
Initial Penalty 4148.0
Final Order 2024-02-26
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1):The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. On or about December 5th, 2023 Location: 25 Barker St, Unit 86, Mount Kisco, NY 10549 a) Employee using a pneumatic roof nail gun without eye protection.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2024-01-30
Current Penalty 2910.0
Initial Penalty 4839.0
Final Order 2024-02-26
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): On or about December 5th, 2023 Location: 25 Barker St, Unit 86, Mount Kisco, NY 10549 a) Employees were exposed to an approximate 30ft fall hazard while working on the roof a 3-story residential building with no fall protection.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260503 A02
Issuance Date 2024-01-30
Abatement Due Date 2024-03-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-02-26
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(2): The employer did not assure that each employee exposed to fall hazards was trained by a competent person qualified in the areas specified in 29 CFR 1926.503 (a)(2)(i) through (viii) On or about December 5th, 2023 Location: 25 Barker St, Unit 86, Mount Kisco, NY 10549 a) Employees working on a pitched roof did not have training on fall protection. Employees were exposed to an approximate 30ft fall hazard while working on the roof a 3-story residential building with no fall protection.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2024-01-30
Current Penalty 2910.0
Initial Penalty 4839.0
Final Order 2024-02-26
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1):When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. On or about December 5th, 2023 Location: 25 Barker St, Unit 86, Mount Kisco, NY 10549 a) Employees were exposed to 30ft fall due to the ladder used to access the roof not extending 3ft from the end of the roof line.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19261053 B07
Issuance Date 2024-01-30
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-02-26
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(7):Care was not exercised in placing, lashing, or holding a ladder with slip-resistant feet that was used on a slippery surface: On or about December 5th, 2023 Location: 25 Barker St, Unit 86, Mount Kisco, NY 10549 a) Employees were exposed to 30ft fall due to the ladder was properly set at the base. Only one of the ladder slip-resistant foot was set on the asphalt surface.