Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-12-05
|
Emphasis |
N: FALL
|
Case Closed |
2024-11-29
|
Related Activity
Type |
Complaint |
Activity Nr |
2109763 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1714879 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19260102 A01 |
Issuance Date |
2024-01-30 |
Current Penalty |
0.0 |
Initial Penalty |
4148.0 |
Final Order |
2024-02-26 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.102(a)(1):The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. On or about December 5th, 2023 Location: 25 Barker St, Unit 86, Mount Kisco, NY 10549 a) Employee using a pneumatic roof nail gun without eye protection. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2024-01-30 |
Current Penalty |
2910.0 |
Initial Penalty |
4839.0 |
Final Order |
2024-02-26 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Imminent Danger |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): On or about December 5th, 2023 Location: 25 Barker St, Unit 86, Mount Kisco, NY 10549 a) Employees were exposed to an approximate 30ft fall hazard while working on the roof a 3-story residential building with no fall protection. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19260503 A02 |
Issuance Date |
2024-01-30 |
Abatement Due Date |
2024-03-18 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-02-26 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Imminent Danger |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(2): The employer did not assure that each employee exposed to fall hazards was trained by a competent person qualified in the areas specified in 29 CFR 1926.503 (a)(2)(i) through (viii) On or about December 5th, 2023 Location: 25 Barker St, Unit 86, Mount Kisco, NY 10549 a) Employees working on a pitched roof did not have training on fall protection. Employees were exposed to an approximate 30ft fall hazard while working on the roof a 3-story residential building with no fall protection. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2024-01-30 |
Current Penalty |
2910.0 |
Initial Penalty |
4839.0 |
Final Order |
2024-02-26 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Imminent Danger |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1):When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. On or about December 5th, 2023 Location: 25 Barker St, Unit 86, Mount Kisco, NY 10549 a) Employees were exposed to 30ft fall due to the ladder used to access the roof not extending 3ft from the end of the roof line. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19261053 B07 |
Issuance Date |
2024-01-30 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-02-26 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Imminent Danger |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(7):Care was not exercised in placing, lashing, or holding a ladder with slip-resistant feet that was used on a slippery surface: On or about December 5th, 2023 Location: 25 Barker St, Unit 86, Mount Kisco, NY 10549 a) Employees were exposed to 30ft fall due to the ladder was properly set at the base. Only one of the ladder slip-resistant foot was set on the asphalt surface. |
|
|