Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-01-16
|
Case Closed |
2015-03-16
|
Related Activity
Type |
Complaint |
Activity Nr |
924303 |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19261101 F01 I |
Issuance Date |
2015-01-26 |
Current Penalty |
2800.0 |
Initial Penalty |
2800.0 |
Final Order |
2015-02-24 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1101(f)(1)(i): Where exposure monitoring was required under 29 CFR 1926.1101, the employer did not perform monitoring to determine accurately the airborne concentrations of asbestos to which employees were or potentially were exposed: A.) On or about Monday, December 1, 2014 97-05 & 97-07 Horace Harding Expressway, Corona, NY 11368 (Basement) The employer failed to perform initial employee exposure monitoring within an construction demolition area in which employees were required to remove presumed asbestos containing material (PACM) such as pipe insulation and an existing plaster/blast ceiling. ABATEMENT CERTIFICATION IS NOT REQUIRED |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19261101 G01 I |
Issuance Date |
2015-01-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-02-24 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1101(g)(1)(i): The employer did not use engineering controls and work practices in all operations covered by 29 CFR 1926.1101, regardless of the levels of exposure, in the form of vacuum cleaners equipped with high efficiency particulate air (HEPA) filters to collect all debris and dust containing asbestos containing material and presumed asbestos containing material: A.) On or about Monday, December 1, 2014 at 97-05 & 97-07 Horace Harding Expressway, Corona, NY 11368 (Basement) During the demolition of an existing plaster/blast ceiling with containing possible asbestos containing material (i.e. pipe insulation) the employer failed to use vacuum cleaners equipped with HEPA filters to safely collect generated debris and dust. ABATEMENT CERTIFICATION IS NOT REQUIRED |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19261101 G01 II |
Issuance Date |
2015-01-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-02-24 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1101(g)(1)(ii): The employer did not use engineering controls and work practices in all operations covered by 29 CFR 1926.1101, regardless of the levels of exposure, in the form of wet methods or wetting agents to control employee exposures during asbestos handling, mixing, removal, cutting, application and cleanup: A.) On or about Monday, December 1, 2014 at 97-05 & 97-07 Horace Harding Expressway, Corona, NY 11368 (Basement) In an area in which presumed asbestos containing materials (i.e. existing plaster/blast ceiling) were to be removed/demolished the employer failed to use a wet process exposing employees to asbestos fibers. ABATEMENT CERTIFICATION IS NOT REQUIRED |
|
Citation ID |
01001D |
Citaton Type |
Serious |
Standard Cited |
19261101 H03 I A |
Issuance Date |
2015-01-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-02-24 |
Nr Instances |
1 |
Nr Exposed |
6 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1101(h)(3)(i)(A): The employer selected or used filtering facepiece respirator against asbestos fibers: A.) On or about Monday, December 1, 2014 at 97-05 & 97-07 Horace Harding Expressway, Corona, NY 11368 Employees required to demolish/remove an existing plaster/blast ceiling with possible asbestos containing material (i.e. pipe insulation) were provided filtering facepiece respirators as a means of respirator protection. ABATEMENT CERTIFICATION IS NOT REQUIRED |
|
Citation ID |
01001E |
Citaton Type |
Serious |
Standard Cited |
19261101 K09 I |
Issuance Date |
2015-01-26 |
Abatement Due Date |
2015-03-13 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-02-24 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1101(k)(9)(i): The employer did not ensure participation in the asbestos training program by each employee who was likely to be exposed to asbestos in excess of the permissible exposure limit (PEL), or for each employee engaged in Class I through Class IV asbestos operations: A.) On or about Monday, December 1, 2014 at 97-05 & 97-07 Horace Harding Expressway, Corona, NY 11368 The employer failed to ensure employees that were required to perform Class I asbestos operations while demolishing an existing plaster/blast ceiling containing possible asbestos containing material (i.e. pipe insulation) were provided asbestos awareness training. ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19 |
|
|