Name: | WINDHAM CONTRACTING CORP. |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Active |
Date of registration: | 29 Dec 2009 (15 years ago) |
Entity Number: | 3893096 |
ZIP code: | 11106 |
County: | Queens |
Place of Formation: | New York |
Address: | 2327 31ST ROAD SUITE 402, ASTORIA, NY, United States, 11106 |
Contact Details
Phone +1 917-225-9020
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Name | Role | Address |
---|---|---|
THE CORPORATION | DOS Process Agent | 2327 31ST ROAD SUITE 402, ASTORIA, NY, United States, 11106 |
Number | Status | Type | Date | End date |
---|---|---|---|---|
1371439-DCA | Inactive | Business | 2010-09-17 | 2011-06-30 |
Start date | End date | Type | Value |
---|---|---|---|
2009-12-29 | 2024-09-28 | Shares | Share type: NO PAR VALUE, Number of shares: 200, Par value: 0 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
091229000118 | 2009-12-29 | CERTIFICATE OF INCORPORATION | 2009-12-29 |
Fee Sequence Id | Fee type | Status | Date | Amount | Description |
---|---|---|---|---|---|
1024741 | LICENSE | INVOICED | 2010-09-17 | 50 | Home Improvement Contractor License Fee |
1024740 | FINGERPRINT | INVOICED | 2010-09-17 | 75 | Fingerprint Fee |
1024742 | TRUSTFUNDHIC | INVOICED | 2010-09-17 | 200 | Home Improvement Contractor Trust Fund Enrollment Fee |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
339848129 | 0215000 | 2014-07-09 | 182 W 82ND STREET, NEW YORK, N.Y. 10024, NEW YORK, NY, 10024 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 897811 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260451 G01 |
Issuance Date | 2015-01-06 |
Abatement Due Date | 2015-01-12 |
Current Penalty | 1400.0 |
Initial Penalty | 2000.0 |
Final Order | 2015-01-29 |
Nr Instances | 3 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1m) above a lower level was not protected from falling to that lower level. Paragraphs (g)(1)(i) though (vii) establish the types of fall protection to be provided to employees on each type of scaffold. Paragraph (g)(2) addresses fall protection for scaffold erectors and dismantlers: a) During masonry activities, employees were exposed to fall hazards on the 50 ft scaffold at the back of the building; the scaffold had multiple platforms which had no midrails or endrails for fall protection. Location: 182 W 82nd Street, New York, N.Y. On or about 7/9/2014 NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260451 H02 |
Issuance Date | 2015-01-06 |
Abatement Due Date | 2015-01-12 |
Current Penalty | 1050.0 |
Initial Penalty | 1600.0 |
Final Order | 2015-01-29 |
Nr Instances | 3 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(h)(2): Where there is the danger of tools, materials, or equipment falling from a scaffold and striking employees below, the employer did not provide preventive measures; to include: i) Barricade the area below the scaffold; or ii) Erect toeboards on the scaffold; with minimum height 3.5 inch toeboard; or iii) Install paneling or screening if toeboard is insufficient height; or iv) Install a guardrail system with openings small enough to prevent passage of falling objects; or v) Erect a canopy structure, debris net, or catch platform above employees working below the scaffold. a) Employees were exposed to falling objects during construction activities at the back of the building where stray cinderblocks were left on various levels of the 50 ft tall scaffold; there were toeboards or other means to prevent falling objects. Location: 182 W 82nd Street, New York, N.Y. On or about 7/9/2014 NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260701 B |
Issuance Date | 2015-01-06 |
Abatement Due Date | 2015-01-12 |
Current Penalty | 1050.0 |
Initial Penalty | 1600.0 |
Final Order | 2015-01-29 |
Nr Instances | 3 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.701(b): All protruding reinforcement steel, onto and into which employees can fall, was not guarded to eliminate the hazard of impalement: a) Employees were exposed to impalement hazard on uncapped rebar rods. Employee was standing above uncapped rebar when doing masonry work on a window opening; located at the back of the building. Location: 182 W 82nd Street, New York, N.Y. On or about 7/9/2014 NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19. |
Inspection Type | Complaint |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2012-10-12 |
Case Closed | 2013-02-19 |
Related Activity
Type | Complaint |
Activity Nr | 613810 |
Safety | Yes |
Date of last update: 27 Mar 2025