Search icon

A.J. MIRANDA GENERAL CONSTRUCTION CORPORATION

Company Details

Name: A.J. MIRANDA GENERAL CONSTRUCTION CORPORATION
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Inactive
Date of registration: 07 Jan 2010 (15 years ago)
Date of dissolution: 29 Jun 2016
Entity Number: 3896609
ZIP code: 10550
County: Westchester
Place of Formation: New York
Address: 86 GRAMATAN AVE, MT VERNON, NY, United States, 10550

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
KEY ACCOUNTING AND TAX SERVICES INC DOS Process Agent 86 GRAMATAN AVE, MT VERNON, NY, United States, 10550

Filings

Filing Number Date Filed Type Effective Date
DP-2169601 2016-06-29 DISSOLUTION BY PROCLAMATION 2016-06-29
100107000316 2010-01-07 CERTIFICATE OF INCORPORATION 2010-01-07

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
334043023 0216000 2012-03-15 41 CHATSWORTH AVE, LARCHMONT, NY, 10538
Inspection Type Referral
Scope Complete
Safety/Health Safety
Close Conference 2012-03-15
Case Closed 2019-07-30

Related Activity

Type Referral
Activity Nr 218485
Safety Yes
Type Inspection
Activity Nr 281901
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 A01
Issuance Date 2012-06-15
Current Penalty 3000.0
Initial Penalty 3000.0
Final Order 2012-07-11
Nr Instances 2
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(a)(1): Scaffold(s) and scaffold(s) component(s) were not capable of supporting, without failure, its own weight and at least four times the maximum intended load applied or transmitted to it: Location: 41 Chatsworth Ave Larchmont NY On or about 3/15/12, a) Engineered wood was used as scaffold planks. It was not designed to be side loaded.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260454 B02
Issuance Date 2012-06-15
Abatement Due Date 2012-06-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-07-11
Nr Instances 4
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(b)(2): Employees were not trained in the correct procedures for erecting, disassembling, moving, operating, repairing, inspecting, and maintaining the type of scaffold in question; Location: 41 Chatsworth Ave Larchmont NY On or about 3/15/12, a) Employees were not trained how to properly erect pump jack scaffolds.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2012-06-15
Abatement Due Date 2012-06-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-07-11
Nr Instances 4
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. Location: 41 Chatsworth Ave Larchmont NY On or about 3/15/12, a) Pump jack scaffolds were not set up by adequately trained employees under the supervision of a competent person.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 C03
Issuance Date 2012-06-15
Current Penalty 3000.0
Initial Penalty 3000.0
Final Order 2012-07-11
Nr Instances 4
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(3): Supported scaffold poles, legs, post, frames, and/or uprights were not plumb and braced to prevent swaying and displacement: Location: 41 Chatsworth Ave Larchmont NY On or about 3/15/12, a) Scaffold poles for pump jack scaffolding were not plumb.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2012-06-15
Current Penalty 4200.0
Initial Penalty 4200.0
Final Order 2012-07-11
Nr Instances 4
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: Location: 41 Chatsworth Ave Larchmont NY On or about 3/15/12, a) Employees that worked from pump jack scaffolding were not protected from falling to lower levels.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260452 J02
Issuance Date 2012-06-15
Current Penalty 4200.0
Initial Penalty 4200.0
Final Order 2012-07-11
Nr Instances 2
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary: Location: 41 Chatsworth Ave Larchmont NY On or about 3/15/12, a) Scaffold poles for pump jack scaffolding were not braced at the bottom.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2012-06-15
Current Penalty 3000.0
Initial Penalty 3000.0
Final Order 2012-07-11
Nr Instances 10
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: On or about 3/15/12, a) Two 9.5 ft X 9 ft holes for the future stairway did not have adequate guarding around it. Only one guardrail was provided at approximately 36 inches above the walking working surface. Employees used a ladder set up in the area to access the floor from a lower level. Employees were exposed to falling 1-2 stories to lower levels. b) Wall openings were not adequately guarded and personal fall arrest systems were not in use. Employees were exposed to the hazard of falling 1 - 2 stories. c) A ramp used by employees to access the house from the front yard did not have guardrails. Parts of the ramp were approximately 10 ft above lower levels. Employees were exposed to the hazard of falling to lower levels.
Citation ID 01006
Citaton Type Serious
Standard Cited 19260651 J02
Issuance Date 2012-06-15
Current Penalty 3000.0
Initial Penalty 3000.0
Final Order 2012-07-11
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.651(j)(2): Employees were not protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations, or by a combination of both if necessary: Location: 41 Chatsworth Ave Larchmont NY On or about 3/15/12, a) Lumber and rock were stored at the edge of an excavation next to the portable toilet.
Citation ID 01007
Citaton Type Serious
Standard Cited 19261053 B05 I
Issuance Date 2012-06-15
Current Penalty 3000.0
Initial Penalty 3000.0
Final Order 2012-07-11
Nr Instances 3
Nr Exposed 3
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladders were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support): Location: 41 Chatsworth Ave Larchmont NY On or about 3/15/12, a) Three extension ladders used by employees to wrap the exterior of the building were not setup at the proper angle.
Citation ID 02001
Citaton Type Other
Standard Cited 19260034 C
Issuance Date 2012-06-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-07-11
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.34(c): Means of egress was not continually maintained free of all obstructions or impediments to full instant use in the case of fire or other emergency: Location: 41 Chatsworth Ave Larchmont NY On or about 3/15/12, a) The egress route through the garage was not kept free of obstructions such as rock.
Citation ID 02002
Citaton Type Other
Standard Cited 19260404 F06
Issuance Date 2012-06-15
Abatement Due Date 2012-06-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-07-11
Nr Instances 2
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: Location: 41 Chatsworth Ave Larchmont NY On or about 3/15/12, a) A compressor used to power nail guns was missing its ground pin. b) An extension cord used to power electrical tools was missing its ground pin.

Date of last update: 27 Mar 2025

Sources: New York Secretary of State