Filings

Filing Number Date Filed Type Effective Date
161021000162 2016-10-21 ANNULMENT OF DISSOLUTION 2016-10-21
DP-2169707 2016-06-29 DISSOLUTION BY PROCLAMATION 2016-06-29
100108000754 2010-01-08 CERTIFICATE OF INCORPORATION 2010-01-08

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342503240 0215000 2017-07-26 69 WASHINGTON PLACE, NEW YORK, NY, 10011
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2017-07-26
Emphasis L: FALL, P: FALL
Case Closed 2018-08-27

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2017-09-28
Current Penalty 1500.0
Initial Penalty 2173.0
Final Order 2017-10-17
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles. Site: 69 Washington Place New York, NY On or about 7/26/17 a) Employees using a Chicago electric drill were not provided with eye/face protective wear while replacing damage bricks as part of the renovation project.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260404 F06
Issuance Date 2017-09-28
Current Penalty 1500.0
Initial Penalty 2173.0
Final Order 2017-10-17
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous. Site: 69 Washington Place New York, NY On or about 7/26/17 a) The orange extension cord used to power the Chicago electric drill was missing the ground pin.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2017-09-28
Current Penalty 1500.0
Initial Penalty 2173.0
Final Order 2017-10-17
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. Site: 69 Washington Place New York, NY On or about 7/26/17 a) Employees worked from a tubular welded frame scaffold which did not have means of safe egress. workers climbed the scaffold frames and residential fence to as a means of egress.