344624838
|
0215800
|
2020-02-12
|
1018 ERIE STREET, UTICA, NY, 13502
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2020-02-12
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2021-03-09
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19260100 A |
Issuance Date |
2020-04-23 |
Current Penalty |
5000.0 |
Initial Penalty |
2313.0 |
Contest Date |
2020-05-13 |
Final Order |
2021-01-19 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: a) East end of building, interior, center, on or about 2-12-20: Two employees were setting steel, below an overhead crane, without wearing head protection. |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19260453 B02 V |
Issuance Date |
2020-04-23 |
Current Penalty |
0.0 |
Initial Penalty |
3856.0 |
Contest Date |
2020-05-13 |
Final Order |
2021-01-19 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.453(b)(2)(v): A body belt with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift: a) East end of building, interior, center, on or about 2-12-20: Two employees were working in two separate articulating, extensible boom, aerial lifts, without a safety harness or body belt connected, exposing the employees to a fall hazard of 18 feet. |
|
|
339790370
|
0215800
|
2014-06-02
|
DOLLAR GENERAL, 9501 HIGHWAY 20, BRIDGEWATER, NY, 13313
|
|
Inspection Type |
Complaint
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2014-06-02
|
Emphasis |
L: FALL
|
Case Closed |
2014-09-16
|
Related Activity
Type |
Complaint |
Activity Nr |
892229 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260502 H01 V |
Issuance Date |
2014-08-01 |
Current Penalty |
0.0 |
Initial Penalty |
3500.0 |
Final Order |
2014-09-12 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(h)(1)(v): The safety monitor had other responsibilities which could take the monitor's attention from the monitoring function: a) North end of roof, on or about 6-2-14: Six employees were performing were working on a roof deck while the Safety Monitor was performing work tasks, taking his attention from his safety monitoring duties. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260760 A01 |
Issuance Date |
2014-08-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-09-12 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems: a) North side of roof deck, on or about 6-2-14: Six employees were installing metal roof decking while in a Controlled Decking Zone (CDZ) that did not meet specific requirements and/or qualify as a CDZ, without fall protection, exposing the employees to a fall hazard of 14 to 17 feet. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260760 C03 |
Issuance Date |
2014-08-01 |
Current Penalty |
0.0 |
Initial Penalty |
3500.0 |
Final Order |
2014-09-12 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.760(c)(3): The boundaries of the controlled decking zone were not clearly marked: a) West side of roof deck, on or about 6-2-14: Six employees were installing metal roof decking while in a Controlled Decking Zone (CDZ) that was more than 90 feet away from the leading edge. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19260760 C04 |
Issuance Date |
2014-08-01 |
Abatement Due Date |
2014-08-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-09-12 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.760(c)(4) Each employee working in a CDZ did not complete CDZ training in accordance with 1926.761: a) Entire roof deck, on or about 6-2-14: Employees were installing metal roof decking while in a Controlled Decking Zone (CDZ), without completing the training required for employees working in a CDZ. |
|
Citation ID |
01002C |
Citaton Type |
Serious |
Standard Cited |
19260761 C03 I |
Issuance Date |
2014-08-01 |
Abatement Due Date |
2014-08-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-09-12 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.761(c)(3)(i): Where Controlled Decking Zones were being used, the employer did not assure that each employee had been provided training in the nature of the hazards associated with work within a controlled decking zone: a) Entire roof deck, on or about 6-2-14: Employees were installing metal roof decking while in a Controlled Decking Zone (CDZ), without the training necessary for employees to recognize the nature of the hazards associated with work within a CDZ. |
|
Citation ID |
01002D |
Citaton Type |
Serious |
Standard Cited |
19260761 C03 II |
Issuance Date |
2014-08-01 |
Abatement Due Date |
2014-08-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-09-12 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.761(c)(3)(ii): The employer did not provide training in the establishment, access, proper installation techniques and work practices required by 1926.760(c) and 1926.754(e): a) Entire roof deck, on or about 6-2-14: Employees were installing metal roof decking while in a Controlled Decking Zone (CDZ) without the training necessary for the establishment, access, proper installation techniques, and work practices required for working within a CDZ. |
|
|