Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2013-04-08
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2017-02-07
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260451 B01 |
Issuance Date |
2013-06-18 |
Current Penalty |
2800.0 |
Initial Penalty |
2800.0 |
Final Order |
2013-07-17 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Imminent Danger |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports: A) 2754 Hylan Blvd, Staten Island, NY 10306: Employees were exposed to fall hazard of approximately 148 due to missing planking at the rear of the scaffold on the first and second levels. Condition observed on or about April 8, 2013. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260451 E01 |
Issuance Date |
2013-06-18 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-07-17 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Imminent Danger |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(e)(1): For scaffold platforms more than two feet above or below a point of access, portable ladders, hook on ladders, attachable ladders, ramps, walkways. Integral prefabricated scaffold access or direct access from another scaffold, structure, personal hoist, or similar surface was not used: A) 2754 Hylan Blvd, Staten Island, NY 10306: Employees were exposed to fall hazards of approximately 14' 8" to the ground below when a ladder was not provided for safe access to a tubular welded scaffold platform. Condition observed on or about April 8, 2013. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 |
Issuance Date |
2013-06-18 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-07-17 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Imminent Danger |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level: A) 2754 Hylan Blvd, Staten Island, NY 10306: Employees were exposed to fall hazards of approximately 14' 8" from the tubular welded scaffold platform in which a fall protection system was not erected or used by employees engaged in stucco refinishing activities. Condition observed on or about April 8, 2013. |
|
|