Search icon

BR-TECK ENTERPRISES, INC.

Company Details

Name: BR-TECK ENTERPRISES, INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 22 Apr 2010 (15 years ago)
Entity Number: 3940586
ZIP code: 11768
County: Suffolk
Place of Formation: New York
Address: 46 WOODBINE AVE, NORTHPORT, NY, United States, 11768

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
BR-TECK ENTERPRISES, INC. DOS Process Agent 46 WOODBINE AVE, NORTHPORT, NY, United States, 11768

Chief Executive Officer

Name Role Address
KAROLYN A DILLON Chief Executive Officer 46 WOODBINE AVE, NORTHPORT, NY, United States, 11768

History

Start date End date Type Value
2012-06-01 2014-05-07 Address 99 WEST HILLS ROAD, HUNTINGTON STATION, NY, 11746, USA (Type of address: Chief Executive Officer)
2012-06-01 2014-05-07 Address 99 WEST HILLS ROAD, HUNTINGTON STATION, NY, 11746, USA (Type of address: Principal Executive Office)
2010-04-22 2014-05-07 Address 99 WEST HILLS ROAD, HUNTINGTON STATION, NY, 11746, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
140507006384 2014-05-07 BIENNIAL STATEMENT 2014-04-01
120601002686 2012-06-01 BIENNIAL STATEMENT 2012-04-01
100422001084 2010-04-22 CERTIFICATE OF INCORPORATION 2010-04-22

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339903262 0214700 2014-08-15 700 HARRISON AVE., RIVERHEAD, NY, 11901
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2014-08-15
Emphasis L: FALL, P: FALL
Case Closed 2015-09-01

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260350 A09
Issuance Date 2014-09-15
Abatement Due Date 2014-09-19
Current Penalty 924.0
Initial Penalty 1320.0
Final Order 2014-09-29
Nr Instances 1
Nr Exposed 6
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.350(a)(9): Compressed gas cylinder(s) were not secured in an upright position: a) worksite, West side fence - Oxygen cylinders were stored against a fence and on their side; on or about 08/15/2014. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260453 B02 IV
Issuance Date 2014-09-15
Current Penalty 2156.0
Initial Penalty 3080.0
Final Order 2014-09-29
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.453(b)(2)(iv): Employee(s) working in an aerial lift were not standing firmly on the floor of the basket: a) worksite - An employee installing decking from a Snorkel model # TB-A50RCU, serial # MY00118, aerial lift, approximately 25 feet above the ground was sitting on the edge of the basket; on or about 08/15/2014. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260453 B02 V
Issuance Date 2014-09-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-09-29
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.453(b)(2)(v): A body belt with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift: a) worksite - An employee installing decking from a Snorkel Model #TB-A50RCU, Serial # MY00118, aerial lift, approximately 25 feet above the ground was not wearing a harness or body belt attached to the boom or basket; on or about 08/15/2014. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260760 A01
Issuance Date 2014-09-15
Current Penalty 2156.0
Initial Penalty 3080.0
Final Order 2014-09-29
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems. a) South side of Steel - Employees cutting installed decking approximately 31 feet 9 inches above the ground were not protected from falling; on or about 08/15/2014. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
339653651 0215600 2014-03-27 16-16 WHITESTONE EXPRESSWAY, FLUSHING, NY, 11357
Inspection Type Referral
Scope Complete
Safety/Health Safety
Close Conference 2014-03-27
Emphasis L: FALL
Case Closed 2014-07-16

Related Activity

Type Referral
Activity Nr 878697
Safety Yes
Type Inspection
Activity Nr 965398
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B03
Issuance Date 2014-04-30
Current Penalty 1000.0
Initial Penalty 2800.0
Final Order 2014-06-26
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(3): Each employee in a hoist area was not protected from falling 6 feet (1.8m) or more to lower levels by guardrail systems or personal fall arrest systems: a) On or about March 27, 2014 - Job site at 16-16 Whitestone Expressway, Flushing NY 11357 Employee was directred to defeat railing system to operate a chainfall while exposed to falls of 11 feet. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260701 B
Issuance Date 2014-04-30
Current Penalty 1750.0
Initial Penalty 2000.0
Final Order 2014-06-26
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall or come against, was not guarded to eliminate the hazard of impalement: a) On or about March 27, 2014 - Job site at 1616 Whitestone Expressway, Flushing NY 11357 Employees were permitted to work above uncapped rebar. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260759 A
Issuance Date 2014-04-30
Current Penalty 1750.0
Initial Penalty 2800.0
Final Order 2014-06-26
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.759(a): 29 CFR 1926.759 (a): Materials, equipment and tools, which were not in use while aloft, were not secured against accidental displacement: a) On or about March 27, 2014 - Job site at 16-16 Whitestone Expressway, Flushing NY 11357 Employee was permitted to use corrugated steel decking bundle as a walking surface to access a chainfall up to 6 feet from the face of the building. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19.