Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2017-08-28
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2024-04-04
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2017-11-13 |
Abatement Due Date |
2017-12-29 |
Current Penalty |
2037.0 |
Initial Penalty |
2716.0 |
Final Order |
2017-12-07 |
Nr Instances |
2 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) At the jobsite, on or about 8/29/17: Workers were working near window openings on the second floor, at the Northwest end, without fall protection of any kind. The second floor deck was 10 feet 10 inches from ground and the sill was measured 2 feet from the second floor deck. b) At the jobsite, on or about 8/29/17: Workers were working near window openings on the second floor, at the Northeast end, without fall protection of any kind. The second floor deck was 10 feet 10 inches from ground and the sill was measured 2 feet from the second floor deck. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19261052 B03 |
Issuance Date |
2017-11-13 |
Abatement Due Date |
2017-12-29 |
Current Penalty |
2852.25 |
Initial Penalty |
3803.0 |
Final Order |
2017-12-07 |
Nr Instances |
3 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1052(b)(3): Treads for temporary stairway service were not installed the full width and/or depth of the stair: a) At the jobsite, on or about 8/29/17: Workers were using a temporary stairway where the treads were not installed the full depth of the stair. This stairway was in Building A, adjacent to the breezeway entrance. b) At the jobsite, on or about 8/29/17: Workers were using a temporary stairway where the treads were not installed the full depth of the stair. This stairway was in Building A, at the South entrance. c) At the jobsite, on or about 8/29/17: Workers were using a temporary stairway where the treads were not installed the full depth of the stair. This stairway was in Building B, at the West entrance. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19261052 C01 I |
Issuance Date |
2017-11-13 |
Abatement Due Date |
2017-12-29 |
Current Penalty |
2852.25 |
Initial Penalty |
3803.0 |
Final Order |
2017-12-07 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: a) At the jobsite, on or about 8/29/17: Workers were using a temporary stairway in Building A at the breezeway entrance, where no handrail was provided on the first flight of stairs. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19261052 C04 |
Issuance Date |
2017-11-13 |
Abatement Due Date |
2017-11-17 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-12-07 |
Nr Instances |
3 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1052(c)(4): Mid-rails, screens, mesh, intermediate vertical members, or equivalent intermediate structural members were not provided between the top rail of the stair-rail system and the stairway steps: a) At the jobsite, on or about 8/29/17: Workers were using a temporary stairway where no mid-rail was provided. This stairway was in Building A, adjacent to the breezeway entrance. b) At the jobsite, on or about 8/29/17: Workers were using a temporary stairway where no mid-rail was provided. This stairway was in Building A, at the South entrance. c) At the jobsite, on or about 8/29/17: Workers were using a temporary stairway where no mid-rail was provided. This stairway was in Building B, at the West entrance. |
|
Citation ID |
01003C |
Citaton Type |
Serious |
Standard Cited |
19261052 C12 |
Issuance Date |
2017-11-13 |
Abatement Due Date |
2017-11-17 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-12-07 |
Nr Instances |
3 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1052(c)(12): Unprotected sides and edges of stairway landings were not provided with guardrail systems that meet the criteria contained in Subpart M of 29 CFR 1926: a) At the jobsite, on or about 8/29/17: Workers were using a temporary stairway where no guardrail system was provided at the first landing. This stairway was in Building A, adjacent to the breezeway entrance. b) At the jobsite, on or about 8/29/17: Workers were using a temporary stairway where no guardrail system was provided at the first landing. This stairway was in Building A, at the South entrance. c) At the jobsite, on or about 8/29/17: Workers were using a temporary stairway where no guardrail system was provided at the first landing. This stairway was in Building B, at the West entrance. |
|
|