Search icon

OSC EQUIPMENT SERVICES, INC.

Headquarter

Company Details

Name: OSC EQUIPMENT SERVICES, INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 11 May 2010 (15 years ago)
Entity Number: 3948421
ZIP code: 14215
County: Erie
Place of Formation: New York
Address: 1001 E. DELAVAN AVE., BUFFALO, NY, United States, 14215

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

Links between entities

Type Company Name Company Number State
Headquarter of OSC EQUIPMENT SERVICES, INC., FLORIDA F23000001282 FLORIDA

DOS Process Agent

Name Role Address
OSC EQUIPMENT SERVICES, INC. DOS Process Agent 1001 E. DELAVAN AVE., BUFFALO, NY, United States, 14215

Chief Executive Officer

Name Role Address
JON M WILLIAMS Chief Executive Officer 1001 E. DELAVAN AVE, BUFFALO, NY, United States, 14215

History

Start date End date Type Value
2024-05-01 2024-05-01 Address 36 AUDUBON, SNYDER, NY, 14226, USA (Type of address: Chief Executive Officer)
2024-05-01 2024-05-01 Address 1001 E. DELAVAN AVE, BUFFALO, NY, 14215, USA (Type of address: Chief Executive Officer)
2023-05-17 2024-05-01 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2023-01-31 2023-05-17 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2020-05-04 2024-05-01 Address 1001 E. DELAVAN AVE., BUFFALO, NY, 14215, USA (Type of address: Service of Process)
2012-06-22 2024-05-01 Address 36 AUDUBON, SNYDER, NY, 14226, USA (Type of address: Chief Executive Officer)
2012-06-22 2020-05-04 Address 333 GANSON STREET, BUFFALO, NY, 14203, USA (Type of address: Principal Executive Office)
2010-05-11 2020-05-04 Address 333 GANSON STREET, BUFFALO, NY, 14203, USA (Type of address: Service of Process)
2010-05-11 2023-01-31 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0

Filings

Filing Number Date Filed Type Effective Date
240501033799 2024-05-01 BIENNIAL STATEMENT 2024-05-01
230126002887 2023-01-26 BIENNIAL STATEMENT 2022-05-01
200504060173 2020-05-04 BIENNIAL STATEMENT 2020-05-01
180509006031 2018-05-09 BIENNIAL STATEMENT 2018-05-01
160509006192 2016-05-09 BIENNIAL STATEMENT 2016-05-01
140530006306 2014-05-30 BIENNIAL STATEMENT 2014-05-01
120622006130 2012-06-22 BIENNIAL STATEMENT 2012-05-01
100511000721 2010-05-11 CERTIFICATE OF INCORPORATION 2010-05-11

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339412959 0213600 2013-09-12 333 GANSON STREET, BUFFALO, NY, 14203
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2013-09-13
Case Closed 2013-12-10

Related Activity

Type Complaint
Activity Nr 852012
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100147 C04 II C
Issuance Date 2013-09-18
Abatement Due Date 2013-10-19
Current Penalty 0.0
Initial Penalty 2975.0
Final Order 2013-10-29
Nr Instances 1
Nr Exposed 10
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(4)(ii)(C): The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them. a) On or about 09/12/2013 in the shop, where the energy control program did not outline and document specific steps for removal of lockout devices by other than the employee who applied the device. ABATEMENT CERTIFICATION REQUIRED
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100147 C06 I
Issuance Date 2013-09-18
Abatement Due Date 2013-10-19
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-10-29
Nr Instances 1
Nr Exposed 5
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) On or about 09/12/2013 in the shop, where employees perform servicing and maintenance such as, but not limited to: changing band saw blades, press brake dies and the shear blade on the Cincinnati shear. ABATEMENT CERTIFICATION REQUIRED
Citation ID 02001
Citaton Type Other
Standard Cited 19100305 G01 IV A
Issuance Date 2013-09-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-10-29
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) On ior about 09/12/2013 in the engine rebuild area; where an extension cord was run in place of fixed wiring to supply power to a parts washer. NO ABATEMENT CERTIFICATION REQUIRED

Motor Carrier Census

USDOT Number Carrier Operation MCS-150 Form Date MCS-150 Mileage MCS-150 Year Power Units Drivers Operation Classification
2919859 Interstate 2023-07-11 65315 2018 2 1 Auth. For Hire, Private(Property)
Legal Name OSC EQUIPMENT SERVICES INC
DBA Name OSC MANUFACTURING AND EQUIPMENT SERVICES
Physical Address 1001 E DELAVAN AVE, BUFFALO, NY, 14215, US
Mailing Address 1001 E DELAVAN AVE, BUFFALO, NY, 14215, US
Phone (716) 800-3333
Fax -
E-mail ACAPPELLO@OSCINC.COM

Safety Measurement System - All Transportation

Total Number of Inspections for the measurement period (24 months) 0
Driver Fitness BASIC Serious Violation Indicator No
Vehicle Maintenance BASIC Acute/Critical Indicator No
Unsafe Driving BASIC Acute/Critical Indicator No
Driver Fitness BASIC Roadside Performance measure value 0
Hours-of-Service (HOS) Compliance BASIC Roadside Performance measure value 0
Total Number of Driver Inspections for the measurment period 0
Vehicle Maintenance BASIC Roadside Performance measure value 0
Total Number of Vehicle Inspections for the measurement period 0
Controlled Substances and Alcohol BASIC Roadside Performance measure value 0
Unsafe Driving BASIC Roadside Performance Measure Value 0
Number of inspections with at least one Driver Fitness BASIC violation 0
Number of inspections with at least one Hours-of-Service BASIC violation 0
Total Number of Driver Inspections containing at least one Driver Out-of-Service Violation 0
Number of inspections with at least one Vehicle Maintenance BASIC violation 0
Total Number of Vehicle Inspections containing at least one Vehicle Out-of-Service violation 0
Number of inspections with at least one Controlled Substances and Alcohol BASIC violation 0
Number of inspections with at least one Unsafe Driving BASIC violation 0

Date of last update: 27 Mar 2025

Sources: New York Secretary of State