Search icon

SKYVIEW SKYLIGHT INC.

Company Details

Name: SKYVIEW SKYLIGHT INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 18 May 2010 (15 years ago)
Entity Number: 3951167
ZIP code: 10931
County: Rockland
Place of Formation: New York
Address: 201 route 59, building a3, HILLBURN, NY, United States, 10931
Principal Address: 201 ROUTE 59, A3, HILLBURN, NY, United States, 10931

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

Chief Executive Officer

Name Role Address
NACHMAN DEUTSCH Chief Executive Officer P.O. BOX 915, HILLBURN, NY, United States, 10931

DOS Process Agent

Name Role Address
SKYVIEW SKYLIGHT INC. DOS Process Agent 201 route 59, building a3, HILLBURN, NY, United States, 10931

Permits

Number Date End date Type Address
APJL-2017828-34563 2017-08-28 2017-08-30 OVER DIMENSIONAL VEHICLE PERMITS No data
X3G8-2017327-9554 2017-03-27 2017-03-29 OVER DIMENSIONAL VEHICLE PERMITS No data
WVY8-2016628-24826 2016-06-28 2016-06-30 OVER DIMENSIONAL VEHICLE PERMITS No data

History

Start date End date Type Value
2024-01-29 2024-01-29 Address P.O. BOX 915, HILLBURN, NY, 10931, USA (Type of address: Chief Executive Officer)
2018-05-02 2024-01-29 Address 201 ROUTE 59, BUILDING A3, HILLBURN, NY, 10931, USA (Type of address: Service of Process)
2014-05-20 2018-05-02 Address 201 ROUTE 59, HILLBURN, NY, 10931, USA (Type of address: Principal Executive Office)
2014-05-20 2024-01-29 Address P.O. BOX 915, HILLBURN, NY, 10931, USA (Type of address: Chief Executive Officer)
2014-05-20 2018-05-02 Address P. O. BOX 915, HILLBURN, NY, 10931, USA (Type of address: Service of Process)
2010-05-18 2024-01-29 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2010-05-18 2014-05-20 Address P. O. BOX 1127, HILLBURN, NY, 10931, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
240129000540 2024-01-29 BIENNIAL STATEMENT 2024-01-29
200522060117 2020-05-22 BIENNIAL STATEMENT 2020-05-01
180502006453 2018-05-02 BIENNIAL STATEMENT 2018-05-01
160517006437 2016-05-17 BIENNIAL STATEMENT 2016-05-01
140520006101 2014-05-20 BIENNIAL STATEMENT 2014-05-01
100518000491 2010-05-18 CERTIFICATE OF INCORPORATION 2010-05-18

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343258596 0216000 2018-06-26 201 NY-59, HILLBURN, NY, 10931
Inspection Type Unprog Rel
Scope Partial
Safety/Health Health
Close Conference 2018-07-12
Case Closed 2019-09-04

Related Activity

Type Referral
Activity Nr 1353048
Safety Yes
Type Inspection
Activity Nr 1336277
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100136 A
Issuance Date 2018-09-28
Abatement Due Date 2018-02-28
Current Penalty 600.0
Initial Penalty 2217.0
Contest Date 2018-10-17
Final Order 2019-01-28
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.136(a): The employer did not ensure that each affected employee used protective footwear when working in areas where there was a danger of foot injuries due to falling or rolling objects, or objects piercing the sole, and where such employee's feet were exposed to electrical hazards: a) Entire Facility: Employees moved stacks of wood, skylight frames, roof hatches, compressed gas cylinders, compressors, etc. and were not required to wear appropriate protective footwear (e.g., safety shoes or equivalent); on or about 6/26/18.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100252 B02 III
Issuance Date 2018-09-28
Abatement Due Date 2018-02-28
Current Penalty 600.0
Initial Penalty 2217.0
Contest Date 2018-10-17
Final Order 2019-01-28
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields: a) Shop Welding Area: MIG welding was being performed and employees that were working in areas adjacent to the welding area were not protected from arc rays by screens or shields as required by the standard; on or about 6/26/18.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19101200 E01
Issuance Date 2018-09-28
Abatement Due Date 2018-02-28
Current Penalty 800.0
Initial Penalty 2217.0
Contest Date 2018-10-17
Final Order 2019-01-28
Nr Instances 1
Nr Exposed 8
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, material safety data sheets, and employee information and training will be met: a) Entire Shop: Employees handled and used various hazardous chemicals including but not limited to: acetone, xylene, stainless steel soldering flux (phosphoric acid), Rustoleum paint (e.g. petroleum distillates , acetone, xylene), argon gas in compressed cylinders), et and the employer did not develop and implement a written hazard communication program on or about 6/28/18.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19101200 G01
Issuance Date 2018-09-28
Abatement Due Date 2018-11-02
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2018-10-17
Final Order 2019-01-28
Nr Instances 1
Nr Exposed 8
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(g)(1): Chemical manufacturers and importers shall obtain or develop a safety data sheet for each hazardous chemical they produce or import. Employers shall have a safety data sheet in the workplace for each hazardous chemical which they use. a) Entire Shop: Employees handled and used various hazardous chemicals including but not limited to: acetone, xylene, stainless steel soldering flux (phosphoric acid), Rustoleum paint (e.g. petroleum distillates , acetone, xylene), argon gas in compressed cylinders) and the employer did not have safety data sheets in the workplace; on or about 6/28/18.
Citation ID 01003C
Citaton Type Serious
Standard Cited 19101200 H01
Issuance Date 2018-09-28
Abatement Due Date 2018-11-02
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2018-10-17
Final Order 2019-01-28
Nr Instances 1
Nr Exposed 8
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) Entire Shop: Employees handled and used various hazardous chemicals including but not limited to: acetone, xylene, stainless steel soldering flux (phosphoric acid), Rustoleum paint (e.g. petroleum distillates , acetone, xylene), argon gas in compressed cylinders), et and the employer did not provide information and training on the hazards of the chemicals that employees were using; on or about 6/28/18.
Citation ID 02001
Citaton Type Other
Standard Cited 19100134 C02 I
Issuance Date 2018-09-28
Abatement Due Date 2018-11-02
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2018-10-17
Final Order 2019-01-28
Nr Instances 1
Nr Exposed 7
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: a) Entire Facility: Employees who were allowed to voluntarily use N95 filtering facepiece respirators were not provided with Appendix D of the OSHA Respiratory Protection Standard; on or about 7/12/18.
343362778 0216000 2018-06-26 201 ROUTE 59 BUILDING A3, HILLBURN, NY, 10931
Inspection Type Referral
Scope Complete
Safety/Health Safety
Close Conference 2018-07-12
Emphasis N: AMPUTATE
Case Closed 2019-09-04

Related Activity

Type Referral
Activity Nr 1353048
Safety Yes
Type Inspection
Activity Nr 1325859
Health Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100036 G02
Issuance Date 2018-09-28
Current Penalty 800.0
Initial Penalty 2956.0
Contest Date 2018-10-17
Final Order 2019-01-28
Nr Instances 3
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points: On or about June 26, 2018, Location towards the rear of the front room, The main room is a big open room were multiple window frames that were being constructed. There were multiple exit routes; when facing the back the measurements from left to right of the exits were approximately; 11 1/2 inches, 16 1/2 inches, 16 1/2 inches, 20 1/2 inches, 24 inches.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100178 L
Issuance Date 2018-09-28
Abatement Due Date 2019-02-28
Current Penalty 800.0
Initial Penalty 2956.0
Contest Date 2018-10-17
Final Order 2019-01-28
Nr Instances 3
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l): Operators were not trained in the safe operation of powered industrial trucks: On or about June 26, 2018 Location: Entire facility a) The employer had not assured that the forklift operators were competent to operate the forklift, which was being used to unload heavy material and load skylight frames from a truck, as demonstrated by the successful completion of the training and evaluation.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100213 C03
Issuance Date 2018-09-28
Current Penalty 1000.0
Initial Penalty 3696.0
Contest Date 2018-10-17
Final Order 2019-01-28
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: On or about June 26, 2018 Location: In the main room towards the back exit. a) Employees used the hand-fed circular ripsaw without a non-kickback fingers or dogs exposing them to the kickback of the wood when operating the ripsaw.
Citation ID 01004
Citaton Type Serious
Standard Cited 19100243 C03
Issuance Date 2018-09-28
Current Penalty 800.0
Initial Penalty 2956.0
Contest Date 2018-10-17
Final Order 2019-01-28
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.243(c)(3): Abrasive wheels used on vertical portable grinder(s) (right angle head grinders) were not provided with safety guard(s) having a maximum exposure angle of 180 degrees and located between the operator and wheel: On or about June 26, 2018 Location: at the welding station in the front left side of the front room. Employee using the yellow medium vertical portable grinder that was exposed to struck by hazards due to the vertical portable grinder being unguarded.
Citation ID 01005
Citaton Type Serious
Standard Cited 19100253 B02 II
Issuance Date 2018-09-28
Current Penalty 800.0
Initial Penalty 2217.0
Contest Date 2018-10-17
Final Order 2019-01-28
Nr Instances 1
Nr Exposed 9
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons: On or about June 26, 2018 Location: Inside of building, at the main entrance of 201 Route 59, Hillburn Apt A3. At the main entrance cylinders were not secured and were located in a designated water location were employees take breaks and drink water.
Citation ID 01006
Citaton Type Serious
Standard Cited 19100305 G02 II
Issuance Date 2018-09-28
Current Penalty 800.0
Initial Penalty 2956.0
Contest Date 2018-10-17
Final Order 2019-01-28
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap: On or about June 26, 2018, Location: In the front left side of the building when the welder station is located, at 201 Route 59, Hillburn Apt A3 A red and black extension cord approximately 25 feet long had a splice approximately 5 feet from the connector end, exposing employees to inner electrical conductors.

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
9138047304 2020-05-01 0202 PPP 201 route 59 building a3, hillburn, NY, 10931
Loan Status Date 2022-03-23
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 171811
Loan Approval Amount (current) 171811
Undisbursed Amount 0
Franchise Name -
Lender Location ID 456756
Servicing Lender Name Cross River Bank
Servicing Lender Address 885 Teaneck Rd, TEANECK, NJ, 07666-4546
Rural or Urban Indicator U
Hubzone N
LMI N
Business Age Description Existing or more than 2 years old
Project Address hillburn, ROCKLAND, NY, 10931-0001
Project Congressional District NY-17
Number of Employees 19
NAICS code 332321
Borrower Race Unanswered
Borrower Ethnicity Not Hispanic or Latino
Business Type Corporation
Originating Lender ID 529113
Originating Lender Name Kabbage, Inc.
Originating Lender Address Atlanta, GA
Gender Male Owned
Veteran Non-Veteran
Forgiveness Amount 174447
Forgiveness Paid Date 2021-11-18

Motor Carrier Census

USDOT Number Carrier Operation MCS-150 Form Date MCS-150 Mileage MCS-150 Year Power Units Drivers Operation Classification
2507679 Interstate 2023-09-11 166723 2023 2 2 Private(Property)
Legal Name SKYVIEW SKYLIGHT
DBA Name -
Physical Address 201 RT 59 BLDG A3, HILLBURN, NY, 10931, US
Mailing Address PO BOX 915, HILLBURN, NY, 10931, US
Phone (845) 789-4381
Fax (877) 257-8071
E-mail INFO@SKYVIEWSKYLIGHT.COM

Safety Measurement System - All Transportation

Total Number of Inspections for the measurement period (24 months) 1
Driver Fitness BASIC Serious Violation Indicator No
Vehicle Maintenance BASIC Acute/Critical Indicator No
Unsafe Driving BASIC Acute/Critical Indicator No
Driver Fitness BASIC Roadside Performance measure value 0
Hours-of-Service (HOS) Compliance BASIC Roadside Performance measure value 0
Total Number of Driver Inspections for the measurment period 1
Vehicle Maintenance BASIC Roadside Performance measure value 0
Total Number of Vehicle Inspections for the measurement period 0
Controlled Substances and Alcohol BASIC Roadside Performance measure value 0
Unsafe Driving BASIC Roadside Performance Measure Value 1.5
Number of inspections with at least one Driver Fitness BASIC violation 0
Number of inspections with at least one Hours-of-Service BASIC violation 0
Total Number of Driver Inspections containing at least one Driver Out-of-Service Violation 0
Number of inspections with at least one Vehicle Maintenance BASIC violation 0
Total Number of Vehicle Inspections containing at least one Vehicle Out-of-Service violation 0
Number of inspections with at least one Controlled Substances and Alcohol BASIC violation 0
Number of inspections with at least one Unsafe Driving BASIC violation 1

Date of last update: 27 Mar 2025

Sources: New York Secretary of State