Name: | JAY DIFULVIO & ASSOCIATES, INC. |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Inactive |
Date of registration: | 08 Apr 1976 (49 years ago) |
Date of dissolution: | 22 May 2023 |
Entity Number: | 396623 |
ZIP code: | 13202 |
County: | Onondaga |
Place of Formation: | New York |
Address: | WEST JEFFERSON ST., LOEW BLDG., SYRACUSE, NY, United States, 13202 |
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Name | Role | Address |
---|---|---|
ONONDAGA CARPET CLEANING RENTAL CORP. | DOS Process Agent | WEST JEFFERSON ST., LOEW BLDG., SYRACUSE, NY, United States, 13202 |
Start date | End date | Type | Value |
---|---|---|---|
1976-04-08 | 2023-05-22 | Shares | Share type: NO PAR VALUE, Number of shares: 200, Par value: 0 |
1976-04-08 | 2023-11-13 | Address | WEST JEFFERSON ST., LOEW BLDG., SYRACUSE, NY, 13202, USA (Type of address: Service of Process) |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
231113002490 | 2023-05-22 | CERTIFICATE OF DISSOLUTION-CANCELLATION | 2023-05-22 |
20090511037 | 2009-05-11 | ASSUMED NAME CORP INITIAL FILING | 2009-05-11 |
010420000010 | 2001-04-20 | CERTIFICATE OF AMENDMENT | 2001-04-20 |
A306543-7 | 1976-04-08 | CERTIFICATE OF INCORPORATION | 1976-04-08 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
339440794 | 0215800 | 2013-10-25 | 539 NORTH SALINA STREET, SYRACUSE, NY, 13208 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260304 F |
Issuance Date | 2013-11-27 |
Current Penalty | 1120.0 |
Initial Penalty | 1600.0 |
Final Order | 2014-02-07 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.304(f): Section 4.1.2(b) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Electrically driven equipment was not equipped with magnetic switches or other devices that will prevent automatic restarting of the machine after a power failure: a) 539 South Salina Street - On or about 25 October, 2013 - Employees were using a table saw to rip wood that did not have an anti restart device on the table saw. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19260304 H01 |
Issuance Date | 2013-11-27 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2014-02-07 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.304(h)(1): Each circular crosscut table saw was not guarded by a hood which completely enclosed that portion of the saw blade above the table and that portion of the saw above the material being cut: a) 539 South Salina Street - On or about 25 October, 2013- Employees were using a table saw to cut wood that was not guarded by a hood which enclosing the saw blade above the table. |
Citation ID | 01001C |
Citaton Type | Serious |
Standard Cited | 19260304 F |
Issuance Date | 2013-11-27 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2014-02-07 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.304(f): Section 4.1.2(b) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws were not equipped with a spreader to prevent material from squeezing the saw or being thrown back on the operator: a) 539 South Salina Street - On or about 25 October, 2013- Employees were using a table saw to rip wood that did not have a spreader installed on the table saw. |
Citation ID | 01001D |
Citaton Type | Serious |
Standard Cited | 19260304 F |
Issuance Date | 2013-11-27 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2014-02-07 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.304(f): Section 4.1.2(c) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws did not have non-kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: a) 539 South Salina Street - On or about 25 October, 2013 - Employees were using a table saw to rip wood that did not have non-kickback fingers installed on the table saw. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260453 B02 IV |
Issuance Date | 2013-11-27 |
Current Penalty | 0.0 |
Initial Penalty | 1600.0 |
Final Order | 2014-02-07 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.453(b)(2)(iv): Employee(s) working in an aerial lift were not standing firmly on the floor of the basket: a) 539 South Salina Street - On or about 25 October, 2013 - Employees were working in an elevated aerial lift and were not standing firmly on the floor of the basket. |
Citation ID | 01003A |
Citaton Type | Serious |
Standard Cited | 19260404 F06 |
Issuance Date | 2013-11-27 |
Abatement Due Date | 2013-12-10 |
Current Penalty | 840.0 |
Initial Penalty | 1200.0 |
Final Order | 2014-02-07 |
Nr Instances | 2 |
Nr Exposed | 3 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) 539 South Salina Street - On or about 25 October, 2013 - Employees were using extensions cords to power tools that did not have the ground prong. |
Citation ID | 01003B |
Citaton Type | Serious |
Standard Cited | 19260404 B01 II |
Issuance Date | 2013-11-27 |
Abatement Due Date | 2013-12-10 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2014-02-07 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection. a) 539 South Salina Street - On or about 25 October, 2013 - Employees were using extension cords to power tools that were not protected by a ground fault circuit interrupter. |
Citation ID | 01003C |
Citaton Type | Serious |
Standard Cited | 19260405 G01 III B |
Issuance Date | 2013-11-27 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2014-02-07 |
Nr Instances | 2 |
Nr Exposed | 3 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.405(g)(1)(iii)(B): Flexible cords and cables were run through holes in walls, ceilings, or floors: a) 539 South Salina Street - On or about 25 October, 2013 - Employees were using flexible cords that were run through a hole in the floor. |
Citation ID | 01003D |
Citaton Type | Serious |
Standard Cited | 19260405 G02 IV |
Issuance Date | 2013-11-27 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2014-02-07 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: a) 539 South Salina Street - On or about 25 October, 2013- Employees were using a table saw that was missing the strain relief on the plug. |