Search icon

COUSINS CONSTRUCTION LLC

Company Details

Name: COUSINS CONSTRUCTION LLC
Jurisdiction: New York
Legal type: DOMESTIC LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 30 Jun 2010 (15 years ago)
Entity Number: 3967958
ZIP code: 12302
County: Schenectady
Place of Formation: New York
Address: 917 SACANDAGA ROAD, SCHENECTADY, NY, United States, 12302

form 5500

Plan Name Plan Year EIN/PN Received Sponsor Total number of participants
COUSINS CONSTRUCTION 401 K PROFIT SHARING PLAN TRUST 2015 451642980 2016-07-29 COUSINS CONSTRUCTION 2
File View Page
Three-digit plan number (PN) 001
Effective date of plan 2014-01-01
Business code 238100
Sponsor’s telephone number 5187013255
Plan sponsor’s address 20 HIBBARD ST, AMSTERDAM, NY, 12010

Signature of

Role Plan administrator
Date 2016-07-29
Name of individual signing JASON HALL
COUSINS CONSTRUCTION 401 K PROFIT SHARING PLAN TRUST 2014 451642980 2015-07-29 COUSINS CONSTRUCTION 4
File View Page
Three-digit plan number (PN) 001
Effective date of plan 2014-01-01
Business code 238100
Sponsor’s telephone number 5187013255
Plan sponsor’s address 917 SACANDAGA RD, GLENVILLE, NY, 12302

Signature of

Role Plan administrator
Date 2015-07-29
Name of individual signing JASON HALL

DOS Process Agent

Name Role Address
JASON HALL DOS Process Agent 917 SACANDAGA ROAD, SCHENECTADY, NY, United States, 12302

Filings

Filing Number Date Filed Type Effective Date
110113000912 2011-01-13 CERTIFICATE OF PUBLICATION 2011-01-13
100630000329 2010-06-30 ARTICLES OF ORGANIZATION 2010-06-30

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344837729 0213100 2020-07-15 10 ALLEN STREET, GLOVERSVILLE, NY, 12078
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2020-07-15
Emphasis P: FALL, L: FALL
Case Closed 2023-06-28

Related Activity

Type Inspection
Activity Nr 1483822
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2020-11-24
Current Penalty 2458.0
Initial Penalty 2458.0
Final Order 2020-12-21
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) 10 Allen Street Gloversville, NY on or about July 16, 2020, employees on a multi-employer jobsite were engaging in roofing operations on a residential two story home utilizing an extension ladder for access tot he roof that did not extend beyond the three feet for safe access, exposing employees to a fall hazard.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260501 B13
Issuance Date 2020-11-24
Abatement Due Date 2020-12-01
Current Penalty 5783.0
Initial Penalty 5783.0
Final Order 2020-12-21
Nr Instances 2
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) 10 Allen Street Gloversville, NY on or about July 15, 2020, employees on a multi-employer jobsite were engaging in roofing operations on a residential two story home with no fall protection or improper fall protection and were exposed to a fall hazard. b) 10 Allen Street Gloversville, NY on or about July 16, 2020, employees on a multi-employer jobsite were engaging in roofing operations on a residential two story home with no fall protection or improper fall protection employees did not hammer in anchor points and disguised the anchor points under bundles of shingles so that it appeared they were anchored off to the roof. Cousins Construction, LLC. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501 (b)(13), which was contained in OSHA inspection number 1169198, citation number 1, item number 1A and was affirmed as a final order on 10/19/2016, with respect to a workplace located at 55 Wilton Rd. Greenfield Center, NY 12833
341691988 0213100 2016-08-12 55 WILTON RD., GREENFIELD CENTER, NY, 12833
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2016-08-12
Emphasis L: FALL
Case Closed 2019-12-13

Related Activity

Type Complaint
Activity Nr 1124369
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2016-08-25
Abatement Due Date 2016-09-06
Current Penalty 2700.0
Initial Penalty 3742.0
Final Order 2016-10-19
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Main house - On or about August 12, 2016 and at times prior thereto, employees were exposed to falls from a steep sloped roof in excess of 11'2" from the ground.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260502 D10 I
Issuance Date 2016-08-25
Abatement Due Date 2016-09-06
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-10-19
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(d)(10)(i): Except as provided in paragraph (d)(10)(ii) of this section, when vertical lifelines were used, each employee was not attached to a separate lifeline: a) Main house - On or about August 12, 2016 and at times prior thereto, employees were using one vertical lifeline as part of a rope grab system for multiple employees use. This was the only anchor/lifeline installed for 3 employees on the roof.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260502 D15
Issuance Date 2016-08-25
Abatement Due Date 2016-09-06
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-10-19
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(d)(15): Anchorages used for attachment of personal fall arrest equipment were not independent of any anchorage being used to support or suspend platforms and/or were not capable of supporting at least 5,000 pounds (22.2 kN) per employee: a) Main house - On or about August 12, 2016 and at times prior thereto, employees were using the installed slide guard deck to install an anchor. The plank and brackets are only capable of withstanding 2500 lbs of force.
Citation ID 02001
Citaton Type Other
Standard Cited 19260503 B01
Issuance Date 2016-08-25
Abatement Due Date 2016-09-06
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-10-19
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Complaint
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer: a) Main house - On or about August 12, 2016 and at times prior thereto, employees were exposed to fall hazards while performing roofing work on a steep sloped roof with a ground to eave height of 11'2". The employer could not verify that employees had been trained with a written certification.

Date of last update: 27 Mar 2025

Sources: New York Secretary of State