343141917
|
0215000
|
2018-05-01
|
824 E. NEW YORK AVENUE, BROOKLYN, NY, 11203
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2018-05-01
|
Emphasis |
L: FALL, L: LOCALTARG, P: LOCALTARG
|
Case Closed |
2019-08-27
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 B01 |
Issuance Date |
2018-10-30 |
Current Penalty |
0.0 |
Initial Penalty |
5691.0 |
Contest Date |
2018-11-02 |
Final Order |
2019-03-06 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports such that the space between adjacent units, and the space between the platform and the uprights . a) The formwork outrigger scaffold platform being used by employees was not fully planked; platform has room for 3 planks but only had 2; employees were exposed. Loc front-left of construction site. Location: 824 E. New York Ave, Brooklyn, NY On or about 5/1/2018 NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19. |
|
Citation ID |
01004A |
Citaton Type |
Other |
Standard Cited |
19261051 A |
Issuance Date |
2018-10-30 |
Abatement Due Date |
2018-11-06 |
Current Penalty |
8000.0 |
Initial Penalty |
5691.0 |
Contest Date |
2018-11-02 |
Final Order |
2019-03-06 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1051(a): Stairways or ladders were not provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided: a) Employees did not have a ladder when working inside the 12 ft tall formwork enclosure they were building; were climbing the formwork and rebar to get out. Loc; front-center of construction site; Location: 824 E. New York Ave, Brooklyn, NY On or about 5/1/2018 NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 AS PER 29 CFR 1903.19. |
|
Citation ID |
01004B |
Citaton Type |
Other |
Standard Cited |
19261053 B16 |
Issuance Date |
2018-10-30 |
Abatement Due Date |
2018-11-06 |
Current Penalty |
0.0 |
Initial Penalty |
5691.0 |
Contest Date |
2018-11-02 |
Final Order |
2019-03-06 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired a) The 14ft lightweight aluminum ladder the employer was using was damaged; ladder side rails and rungs were bent; located at the formwork enclosure for the tank; Location: 824 E. New York Ave, Brooklyn, NY On or about 5/1/2018 NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 AS PER 29 CFR 1903.19. |
|
|
342194776
|
0215000
|
2017-03-14
|
412 HERKIMER ST., BROOKLYN, NY, 11213
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-03-14
|
Emphasis |
P: LOCALTARG, N: TRENCH, L: LOCALTARG
|
Case Closed |
2019-08-01
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260651 C02 |
Issuance Date |
2017-08-23 |
Current Penalty |
0.0 |
Initial Penalty |
3803.0 |
Contest Date |
2018-08-28 |
Final Order |
2019-04-01 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Imminent Danger |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: Location: 412 Herkimer St. On or about: 14Mar17 a) Employees were working in an excavation that did not have a safe means of egress. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260651 J02 |
Issuance Date |
2017-08-23 |
Abatement Due Date |
2017-08-29 |
Current Penalty |
0.0 |
Initial Penalty |
3803.0 |
Contest Date |
2018-08-28 |
Final Order |
2019-04-01 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Imminent Danger |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.651(j)(2): Employees were not protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations, or by a combination of both if necessary. Location:412 Herkimer St. On or about: 14 Mar17 a) Employees were doing underpinning work in a trench excavation with the spoil piles of dirt and rocks within two feet of the excavation edge |
|
Citation ID |
01003 |
Citaton Type |
Other |
Standard Cited |
19260651 K01 |
Issuance Date |
2017-08-23 |
Abatement Due Date |
2017-09-05 |
Current Penalty |
3500.0 |
Initial Penalty |
3803.0 |
Contest Date |
2018-08-28 |
Final Order |
2019-04-01 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Imminent Danger |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.651(k)(1): An inspection of the excavations, the adjacent areas, and protective systems was not conducted by the competent person prior to the start of work and as needed throughout the shift Location:412 Herkimer St. On or about: 14 Mar17 a) Employees were doing underpinning work in a excavation, an inspection was not done by a competent person before work was started. |
|
|
339566614
|
0215000
|
2014-01-30
|
4506 12TH AVENUE, BROOKLYN, NY, 11219
|
|
Inspection Type |
Unprog Rel
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2014-01-30
|
Emphasis |
L: FALL
|
Case Closed |
2014-04-16
|
Related Activity
Type |
Inspection |
Activity Nr |
941020 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
956668 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19260020 B02 |
Issuance Date |
2014-02-27 |
Abatement Due Date |
2014-03-11 |
Current Penalty |
1000.0 |
Initial Penalty |
2000.0 |
Final Order |
2014-03-24 |
Nr Instances |
1 |
Nr Exposed |
7 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s) Location: 4506 12th Ave, Brooklyn, NY 11219, throughout in and around job site On or about September 12, 2013 a) A competent person did not maintain and implement a program for frequent and regular inpsections of the job-site. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2014-02-27 |
Current Penalty |
1800.0 |
Initial Penalty |
2800.0 |
Final Order |
2014-03-24 |
Nr Instances |
3 |
Nr Exposed |
7 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. Location: 4506 12th Ave, Brooklyn, NY 11219 On or about September 12, 2013 a) Employees were exposed to fall hazards by unprotected leading edges on the 5th level. An employee was injured when he fell approximately 40 feet from the 5th level. NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19. |
|
Citation ID |
01003 |
Citaton Type |
Other |
Standard Cited |
19260701 B |
Issuance Date |
2014-02-27 |
Current Penalty |
1000.0 |
Initial Penalty |
2000.0 |
Final Order |
2014-03-24 |
Nr Instances |
40 |
Nr Exposed |
7 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall or come against, was not guarded to eliminate the hazard of impalement. Location: 4506 12th Ave, Brooklyn, NY 11219 On or about September 12, 2013; a) Rebar throughout the 5th Level was not protected with a cap or cover. NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19. |
|
Citation ID |
01006A |
Citaton Type |
Serious |
Standard Cited |
19261052 B01 |
Issuance Date |
2014-02-27 |
Current Penalty |
1800.0 |
Initial Penalty |
2000.0 |
Final Order |
2014-03-24 |
Nr Instances |
2 |
Nr Exposed |
7 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1052(b)(1): Foot traffic was not prohibited on stairways where the treads and/or landings of pan stairs were to be filled in with concrete or other material at a later date and stairs were not temporarily fitted with wood or other solid material at least to the top edge of each pan. Location: 4506 12th Ave, Brooklyn, NY 11219, throughout site on every stairway and landing. On or about September 12, 2013; a) Each stairway and landing from the 1st floor to 5th level was not temporarily filled with wood or other solid material. There were two sets of stairways located on each level and employees used stairways to access floors from 1st floor to 5th level daily during work shift. NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19. |
|
Citation ID |
01006B |
Citaton Type |
Serious |
Standard Cited |
19261052 C01 I |
Issuance Date |
2014-02-27 |
Current Penalty |
0.0 |
Initial Penalty |
2800.0 |
Final Order |
2014-03-24 |
Nr Instances |
2 |
Nr Exposed |
7 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail. Location: 4506 12th Ave, Brooklyn, NY 11219, 1st floor thru 5 level. On or About, September 12, 2013 a) Stairways leading from the 1st floor to 5th level were not equipped with a handrail. Each floor was equipped with two stairways and were the only means of access for employees between the floors. NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19. |
|
Citation ID |
01006C |
Citaton Type |
Serious |
Standard Cited |
19261052 C01 II |
Issuance Date |
2014-02-27 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-03-24 |
Nr Instances |
2 |
Nr Exposed |
7 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one stairrail system along each unprotected side or edge: Location: 4506 12th Ave, Brooklyn, NY 11219, 1st floor thru 5 level. On or About, September 12, 2013 a) Stairways leading from the 1st floor to 5th level were not equipped with a stairrail. Each floor was equipped with two stairways and were the only means of access for employees between the floors. NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19. |
|
|
314980640
|
0216000
|
2011-10-28
|
1224 PROSPECT AVE, BRONX, NY, 10459
|
|
Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2011-11-03
|
Emphasis |
L: FALL, S: ELECTRICAL, S: FALL FROM HEIGHT, S: HISPANIC
|
Case Closed |
2011-12-20
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260021 B02 |
Issuance Date |
2011-11-07 |
Abatement Due Date |
2011-11-10 |
Current Penalty |
1377.0 |
Initial Penalty |
2295.0 |
Nr Instances |
6 |
Nr Exposed |
6 |
Gravity |
05 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260404 F06 |
Issuance Date |
2011-11-07 |
Abatement Due Date |
2011-11-10 |
Current Penalty |
1652.0 |
Initial Penalty |
2754.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
05 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260501 B06 |
Issuance Date |
2011-11-07 |
Abatement Due Date |
2011-11-10 |
Current Penalty |
1652.0 |
Initial Penalty |
2754.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
05 |
|
|