343132338
|
0215600
|
2018-05-01
|
33-46 86TH STREET, JACKSON HEIGHTS, NY, 11372
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-05-01
|
Emphasis |
L: FALL
|
Case Closed |
2018-07-26
|
Related Activity
Type |
Complaint |
Activity Nr |
1334152 |
Safety |
Yes |
|
|
341381259
|
0215600
|
2016-04-07
|
252-79 LEITH ROAD, LITTLE NECK, NY, 11362
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-04-07
|
Case Closed |
2016-04-08
|
Related Activity
Type |
Inspection |
Activity Nr |
1096387 |
Safety |
Yes |
|
|
340963875
|
0215600
|
2015-10-06
|
252-79 LEITH ROAD, LITTLE NECK, NY, 11362
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-10-06
|
Emphasis |
L: FALL, N: CTARGET, P: FALL
|
Case Closed |
2018-12-18
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Repeat |
Standard Cited |
19260095 A |
Issuance Date |
2016-01-07 |
Current Penalty |
10000.0 |
Initial Penalty |
10000.0 |
Final Order |
2016-03-14 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact: a) On or about October 6, 2015- job site at 252-79 Leith Road, Little Neck, NY 11362 the employer permitted an employee to cut ceramic tile with a hand held grinder without wearing eye protection. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED. EUROPEAN ROOFING INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD 1926.102(a) , OR ITS EQUIVALENT, WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 647138, CITATION NUMBER 01, ITEM NUMBER 1b, ISSUED ON 03/14/2013 WHICH BECAME A FINAL ORDER ON 04/04/2013. EUROPEAN ROOFING INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD 1926.102(a) , OR ITS EQUIVALENT, WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 916297, CITATION NUMBER 01, ITEM NUMBER 1b, ISSUED ON 07/10/2013 WHICH BECAME A FINAL ORDER ON 08/06/13. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260300 B01 |
Issuance Date |
2016-01-07 |
Abatement Due Date |
2016-02-25 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Final Order |
2016-03-14 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: a) On or about October 6, 2015- job site at 252-79 Leith Road, Little Neck, NY 11362 the employer permitted an employee to cut ceramic roofing tiles, with a hand held grinder, that did not have a guard. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED. |
|
Citation ID |
02001 |
Citaton Type |
Willful |
Standard Cited |
19260501 B13 |
Issuance Date |
2016-01-07 |
Current Penalty |
30800.0 |
Initial Penalty |
30800.0 |
Final Order |
2016-03-14 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about October 6, 2015- job site at 252-79 Leith Road, Little Neck, NY 11362 the employer permitted his employees to perform roofing work on a pitched roof, approximately 20 feet above the next lower level, and weren't protected by any type of fall protection system. EUROPEAN ROOFING INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD 1926.501(b)(13), OR ITS EQUIVALENT, WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 647138, CITATION NUMBER 01, ITEM NUMBER 003a, ISSUED ON 03/14/2013 WHICH BECAME A FINAL ORDER ON 04/04/2013. EUROPEAN ROOFING INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD 1926.501(b)(13), OR ITS EQUIVALENT, WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 916297, CITATION NUMBER 01, ITEM NUMBER 002a, ISSUED ON 07/10/2013 WHICH BECAME A FINAL ORDER ON 08/08/2013. EUROPEAN ROOFING INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD 1926.501(B)(13), OR ITS EQUIVALENT, WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 984647, CITAION NUMBER 02, ITEM NUMBER 01, ISSUED ON 09/24/14 WHICH BECAME A FINAL ORDER ON 04/30/15. WRITTEN DOCUMENTATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19. |
|
|
340187079
|
0215600
|
2015-01-13
|
10-54 BURTON STREET, BEECHHURST, NY, 11357
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-01-13
|
Case Closed |
2015-01-23
|
Related Activity
Type |
Complaint |
Activity Nr |
931871 |
Safety |
Yes |
|
|
339846479
|
0215600
|
2014-07-10
|
232-09 64 AVE, OAKLAND GARDENS, NY, 11364
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2014-07-10
|
Emphasis |
P: FALL, L: FALL
|
Case Closed |
2017-06-16
|
Related Activity
Type |
Referral |
Activity Nr |
897843 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260404 B01 II |
Issuance Date |
2014-09-25 |
Current Penalty |
830.0 |
Initial Penalty |
2200.0 |
Contest Date |
2014-10-20 |
Final Order |
2015-04-30 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection: a) On or about July 10, 2014-Job Site at 232-09 64 Avenue Oakland Gardens, NY 11364 Employers permitted employees to use an energized power strip designed for indoor, non commercial use, to provide power to a an operational electric ladder hoist on a metal ladder, that could be energized and that was in use without GFCI protection. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260403 B02 |
Issuance Date |
2014-09-25 |
Current Penalty |
830.0 |
Initial Penalty |
2200.0 |
Contest Date |
2014-10-20 |
Final Order |
2015-04-30 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) On or about July 10, 2014-Job Site at 232-09 64 Avenue Oakland Gardens, NY 11364 Employers permitted employees to use an energized power strip designed for indoor, non commercial use. b) On or about July 10, 2014-Job Site at 232-09 64 Avenue Oakland Gardens, NY 11364 The Employer added a replacement female plug end to a flexible cord set without maintaining the original insulation characteristics. The employer used electrical tape to provide added insulation to un-insulated wire. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED. |
|
Citation ID |
02001 |
Citaton Type |
Willful |
Standard Cited |
19260501 B13 |
Issuance Date |
2014-09-25 |
Current Penalty |
11700.0 |
Initial Penalty |
30800.0 |
Contest Date |
2014-10-20 |
Final Order |
2015-04-30 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about July 10, 2014-Job Site at 232-09 64 Avenue Oakland Gardens, NY 11364 Employer permitted employees to work on a roof, 25 feet above the next lower level, without fall protection. b) On or about July 12, 2014-Job Site at 232-09 64 Avenue Oakland Gardens, NY 11364 Employer permitted employees and himself to work on a roof, 25 feet above the next lower level, without fall protection. EUROPEAN ROOFING INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD 1926.501(b)(13), OR ITS EQUIVALENT, WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 647138, CITATION NUMBER 01, ITEM NUMBER 003a, ISSUED ON 03/14/2013 WHICH BECAME A FINAL ORDER DATE ON 04/04/2013. EUROPEAN ROOFING INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD 1926.501(b)(13), OR ITS EQUIVALENT, WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 916297, CITATION NUMBER 01, ITEM NUMBER 002a, ISSUED ON 07/10/2013 WHICH BECAME A FINAL ORDER DATE ON 08/08/2013. WRITTEN DOCUMENTATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19. |
|
Citation ID |
03001 |
Citaton Type |
Repeat |
Standard Cited |
19260100 A |
Issuance Date |
2014-09-25 |
Current Penalty |
1640.0 |
Initial Penalty |
4400.0 |
Contest Date |
2014-10-20 |
Final Order |
2015-04-30 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: a) On or about July 10, 2014-Job Site at 232-09 64 Avenue Oakland Gardens, NY 11364 Employer permitted an employee to work without a protective helmet below roofing installation work that was being performed approximately 25 feet overhead. EUROPEAN ROOFING INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD 1926.100(a), OR ITS EQUIVALENT, WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 647138, CITATION NUMBER 01, ITEM NUMBER 001a, ISSUED ON 03/14/2013 WHICH BECAME A FINAL ORDER DATE ON 04/04/2013. WRITTEN ABATEMENT DOCUMENTATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19. |
|
|
339162976
|
0215600
|
2013-06-24
|
184-45 RADNOR ROAD, JAMAICA, NY, 11412
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2013-06-24
|
Emphasis |
P: FALL, L: FALL
|
Case Closed |
2013-11-05
|
Related Activity
Type |
Referral |
Activity Nr |
828150 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Repeat |
Standard Cited |
19260102 A01 |
Issuance Date |
2013-07-09 |
Current Penalty |
2200.0 |
Initial Penalty |
4400.0 |
Final Order |
2013-08-06 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: On or about June 24, 2013-Job Site at 184-45 Radnor Rd, Jamaica Estates, NY 11432 a) Employee using angle grinder to cut tiles on the roof not wearing eye protection. EUROPEAN ROOFING INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDERD 1926.102 (a)(1), OR ITS EQUIVALENT, WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 647138, CITATION NUMBER 01, ITEM NUMBER 001b, ISSUED ON 03/14/2013 WHICH BECAME A FINAL ORDER DATE ON 04/04/2013. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19. |
|
Citation ID |
01002A |
Citaton Type |
Repeat |
Standard Cited |
19260501 B13 |
Issuance Date |
2013-07-09 |
Current Penalty |
3080.0 |
Initial Penalty |
6160.0 |
Final Order |
2013-08-06 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): On or about June 24, 2013-Job Site at 184-45 Radnor Rd, Jamaica Estates, NY 11432 a) Employees cutting tiles exposed to 30-foot falls without fall protection. EUROPEAN ROOFING INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDERD 1926.501(b)(13), OR ITS EQUIVALENT, WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 647138, CITATION NUMBER 01, ITEM NUMBER 003a, ISSUED ON 03/14/2013 WHICH BECAME A FINAL ORDER DATE ON 04/04/2013. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19. |
|
Citation ID |
01002B |
Citaton Type |
Repeat |
Standard Cited |
19260503 A01 |
Issuance Date |
2013-07-09 |
Abatement Due Date |
2013-08-23 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-08-06 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: On or about June 24, 2012-Job Site at 184-45 Radnor Rd, Jamaica Estates, NY 11432 a) Employees could not identify the need for fall protection when exposed to falls of up to 30-feet while moving and cutting roof tiles. EUROPEAN ROOFING INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDERD 1926.503(a)(1), OR ITS EQUIVALENT, WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 647138, CITATION NUMBER 01, ITEM NUMBER 003b, ISSUED ON 03/14/2013 WHICH BECAME A FINAL ORDER DATE ON 04/04/2013. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19. |
|
|
336471388
|
0215600
|
2012-09-17
|
232-19 64 AVENUE, OAKLAND GARDENS, NY, 11364
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2012-09-17
|
Emphasis |
L: FALL
|
Case Closed |
2013-06-27
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260100 A |
Issuance Date |
2013-03-14 |
Current Penalty |
1400.0 |
Initial Penalty |
2000.0 |
Final Order |
2013-03-21 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns: On or about September 17, 2012-Job Site at 232-19 64 Avenue Oakland Gardens, NY 11364 a) Employees exposed to overhead hazards from roof tiles 25-feet above the next lower level. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260102 A01 |
Issuance Date |
2013-03-14 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-03-21 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: On or about September 17, 2012-Job Site at 232-19 64 Avenue Oakland Gardens, NY 11364 a) Employee using angle grinder to cut tiles on the roof not wearing eye protection. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260405 G02 III |
Issuance Date |
2013-03-14 |
Abatement Due Date |
2013-04-30 |
Current Penalty |
1955.0 |
Initial Penalty |
2800.0 |
Final Order |
2013-03-21 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(g)(2)(iii): The repair splice in a hard service flexible cord No. 12 or larger did not retain the insulation, outer sheath properties, and usage characteristics of the cord which was being used: On or about September 17, 2012-Job Site at 232-19 64 Avenue Oakland Gardens, NY 11364 a)Employees using the tile lifting device on the ladder are exposed to spliced electrical cord. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19 |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2013-03-14 |
Current Penalty |
1955.0 |
Initial Penalty |
2800.0 |
Final Order |
2013-03-21 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): On or about September 17, 2012-Job Site at 232-19 64 Avenue Oakland Gardens, NY 11364 a)Employees putting roof tiles exposed to 25-foot falls without fall protection. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19260503 A01 |
Issuance Date |
2013-03-14 |
Abatement Due Date |
2013-04-30 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-03-21 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: On or about September 17, 2012-Job Site at 232-19 64 Avenue Oakland Gardens, NY 11364 a) Employees could not identify the need for fall protection when exposed to falls of 25-feet while moving and installing roof tiles. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19. |
|
|