Search icon

ROBERT JAMES CONTRACTING CORP.

Company Details

Name: ROBERT JAMES CONTRACTING CORP.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 04 Nov 2010 (14 years ago)
Entity Number: 4015569
ZIP code: 11579
County: Nassau
Place of Formation: New York
Address: 325 GLEN COVE AVENUE, SUITE 1, SEA CLIFF, NY, United States, 11579

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
CHARLES G. MCQUAIR, ESQ. DOS Process Agent 325 GLEN COVE AVENUE, SUITE 1, SEA CLIFF, NY, United States, 11579

History

Start date End date Type Value
2010-11-04 2023-05-20 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0

Filings

Filing Number Date Filed Type Effective Date
101104000388 2010-11-04 CERTIFICATE OF INCORPORATION 2010-11-04

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342529922 0216000 2017-08-02 11 AGNES CIRCLE, ARDSLEY, NY, 10502
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2017-08-02
Emphasis L: FALL
Case Closed 2017-08-03

Related Activity

Type Inspection
Activity Nr 1214904
Safety Yes
342149044 0216000 2017-03-02 11 AGNES CIRCLE, ARDSLEY, NY, 10502
Inspection Type Complaint
Scope Complete
Safety/Health Safety
Close Conference 2017-03-02
Emphasis L: FALL
Case Closed 2023-02-08

Related Activity

Type Complaint
Activity Nr 1188445
Safety Yes
Type Inspection
Activity Nr 1214940
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2017-03-17
Abatement Due Date 2017-03-27
Current Penalty 1130.0
Initial Penalty 1630.0
Final Order 2017-04-14
Nr Instances 6
Nr Exposed 6
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: Location: entire site On or about: 3/2/17 a) Employees working below overhead hazards related to residential construction were not provided with hard hats. NOTE: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260404 F06
Issuance Date 2017-03-17
Current Penalty 1130.0
Initial Penalty 1630.0
Final Order 2017-04-14
Nr Instances 2
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures was not permanent and continuous: location: entire site on or about: 3/2/17 a) An employee was using electrical equipment, including a saw while engaged in residential construction. The equipment were plugged into extension cords. The grounding pin for two of the cords were missing. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2017-03-17
Abatement Due Date 2017-03-29
Current Penalty 2650.0
Initial Penalty 3803.0
Final Order 2017-04-14
Nr Instances 1
Nr Exposed 6
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): Location: 2nd floor On or about: 3/2/17 a) Employees, engaged in residential construction, were not provided with fall protection. The employees were exposed to a fall of 9'3". NOTE: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2017-03-17
Abatement Due Date 2017-04-19
Current Penalty 1890.0
Initial Penalty 2716.0
Final Order 2017-04-14
Nr Instances 6
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed in order to minimize these hazards: Location: 2nd floor On or about: 3/2/17 a) Employees, exposed to fall hazards while renovating a residential house, were not provided with fall protection training. NOTE: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.

Date of last update: 27 Mar 2025

Sources: New York Secretary of State