Name: | ROBERT JAMES CONTRACTING CORP. |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Active |
Date of registration: | 04 Nov 2010 (14 years ago) |
Entity Number: | 4015569 |
ZIP code: | 11579 |
County: | Nassau |
Place of Formation: | New York |
Address: | 325 GLEN COVE AVENUE, SUITE 1, SEA CLIFF, NY, United States, 11579 |
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Name | Role | Address |
---|---|---|
CHARLES G. MCQUAIR, ESQ. | DOS Process Agent | 325 GLEN COVE AVENUE, SUITE 1, SEA CLIFF, NY, United States, 11579 |
Start date | End date | Type | Value |
---|---|---|---|
2010-11-04 | 2023-05-20 | Shares | Share type: NO PAR VALUE, Number of shares: 200, Par value: 0 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
101104000388 | 2010-11-04 | CERTIFICATE OF INCORPORATION | 2010-11-04 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
342529922 | 0216000 | 2017-08-02 | 11 AGNES CIRCLE, ARDSLEY, NY, 10502 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 1214904 |
Safety | Yes |
Inspection Type | Complaint |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 2017-03-02 |
Emphasis | L: FALL |
Case Closed | 2023-02-08 |
Related Activity
Type | Complaint |
Activity Nr | 1188445 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1214940 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260100 A |
Issuance Date | 2017-03-17 |
Abatement Due Date | 2017-03-27 |
Current Penalty | 1130.0 |
Initial Penalty | 1630.0 |
Final Order | 2017-04-14 |
Nr Instances | 6 |
Nr Exposed | 6 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: Location: entire site On or about: 3/2/17 a) Employees working below overhead hazards related to residential construction were not provided with hard hats. NOTE: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260404 F06 |
Issuance Date | 2017-03-17 |
Current Penalty | 1130.0 |
Initial Penalty | 1630.0 |
Final Order | 2017-04-14 |
Nr Instances | 2 |
Nr Exposed | 1 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures was not permanent and continuous: location: entire site on or about: 3/2/17 a) An employee was using electrical equipment, including a saw while engaged in residential construction. The equipment were plugged into extension cords. The grounding pin for two of the cords were missing. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2017-03-17 |
Abatement Due Date | 2017-03-29 |
Current Penalty | 2650.0 |
Initial Penalty | 3803.0 |
Final Order | 2017-04-14 |
Nr Instances | 1 |
Nr Exposed | 6 |
Related Event Code (REC) | Complaint |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): Location: 2nd floor On or about: 3/2/17 a) Employees, engaged in residential construction, were not provided with fall protection. The employees were exposed to a fall of 9'3". NOTE: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
Citation ID | 01004 |
Citaton Type | Serious |
Standard Cited | 19260503 A01 |
Issuance Date | 2017-03-17 |
Abatement Due Date | 2017-04-19 |
Current Penalty | 1890.0 |
Initial Penalty | 2716.0 |
Final Order | 2017-04-14 |
Nr Instances | 6 |
Nr Exposed | 6 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed in order to minimize these hazards: Location: 2nd floor On or about: 3/2/17 a) Employees, exposed to fall hazards while renovating a residential house, were not provided with fall protection training. NOTE: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |