Name: | D ZAHARA CONSTRUCTION CORP. |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Active |
Date of registration: | 13 Dec 2010 (14 years ago) |
Entity Number: | 4030099 |
ZIP code: | 11753 |
County: | Nassau |
Place of Formation: | New York |
Address: | 380 N. BROADWAY, #302, JERICHO, NY, United States, 11753 |
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Name | Role | Address |
---|---|---|
THE CORPORATION | DOS Process Agent | 380 N. BROADWAY, #302, JERICHO, NY, United States, 11753 |
Start date | End date | Type | Value |
---|---|---|---|
2025-02-14 | 2025-03-18 | Shares | Share type: NO PAR VALUE, Number of shares: 200, Par value: 0 |
2024-11-23 | 2025-02-14 | Shares | Share type: NO PAR VALUE, Number of shares: 200, Par value: 0 |
2024-10-12 | 2024-11-23 | Shares | Share type: NO PAR VALUE, Number of shares: 200, Par value: 0 |
2023-12-14 | 2024-10-12 | Shares | Share type: NO PAR VALUE, Number of shares: 200, Par value: 0 |
2023-11-08 | 2023-12-14 | Shares | Share type: NO PAR VALUE, Number of shares: 200, Par value: 0 |
2023-07-31 | 2023-11-08 | Shares | Share type: NO PAR VALUE, Number of shares: 200, Par value: 0 |
2023-07-06 | 2023-07-31 | Shares | Share type: NO PAR VALUE, Number of shares: 200, Par value: 0 |
2023-06-09 | 2023-07-06 | Shares | Share type: NO PAR VALUE, Number of shares: 200, Par value: 0 |
2023-05-24 | 2023-06-09 | Shares | Share type: NO PAR VALUE, Number of shares: 200, Par value: 0 |
2023-05-19 | 2023-05-24 | Shares | Share type: NO PAR VALUE, Number of shares: 200, Par value: 0 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
190419000060 | 2019-04-19 | CERTIFICATE OF CHANGE | 2019-04-19 |
101213000662 | 2010-12-13 | CERTIFICATE OF INCORPORATION | 2010-12-13 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
345916100 | 0215000 | 2022-04-25 | 530 EAST 76 STREET, NEW YORK, NY, 10021 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 1887817 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260405 G02 IV |
Issuance Date | 2022-10-18 |
Abatement Due Date | 2022-10-28 |
Current Penalty | 2550.0 |
Initial Penalty | 4144.0 |
Final Order | 2022-11-18 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws. Location: a) Scaffold; Northeast corner of building a) On or about 4/25/2022, strain relief was not provided to the power cord of the electrical hoist and the cord was damaged. An employee used the electrical hoist to move materials. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260501 B01 |
Issuance Date | 2022-10-18 |
Current Penalty | 4000.0 |
Initial Penalty | 5801.0 |
Final Order | 2022-11-18 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Complaint |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. Location: a) 5th floor parapet wall; Northeast corner of building a) On or about 4/25/2022, an employee stood on a parapet wall without the use of guardrails or personal fall arrest system(s) and was exposed to a fall of approximately 12 feet to the setback area below. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260503 C03 |
Issuance Date | 2022-10-18 |
Abatement Due Date | 2022-11-04 |
Current Penalty | 2550.0 |
Initial Penalty | 4144.0 |
Final Order | 2022-11-18 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(c)(3): When the employer has reason to believe that any affected employee who has already been trained does not have the understanding and skill required by paragraph (a) of this section, the employer did not retrain each such employee, where inadequacies in an affected employee's knowledge or use of fall protection systems or equipment indicate that the employee has not retained the requisite understanding or skill. Location: a) Scaffold; 5th floor parapet wall; Northeast corner of building a) On or about 4/25/2022, the employer did not retrain employees who showed inadequacies with the use of fall protection systems or equipment, when personal fall arrest systems were used on the scaffold and when personal fall arrest systems were not used while standing on the parapet wall. |
Date of last update: 27 Mar 2025