Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-03-07
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2016-06-30
|
Related Activity
Type |
Referral |
Activity Nr |
1069430 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260095 A |
Issuance Date |
2016-04-22 |
Current Penalty |
1000.0 |
Initial Penalty |
2000.0 |
Final Order |
2016-06-09 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact: a) On or about March 7, 2016- job site at 53-09 Marathon Parkway, Little Neck, NY 11362 an employee was using a DeWalt DWE 4011 grinder to cut material without wearing eye protection. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260300 B01 |
Issuance Date |
2016-04-22 |
Abatement Due Date |
2016-04-28 |
Current Penalty |
1000.0 |
Initial Penalty |
2000.0 |
Final Order |
2016-06-09 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: a) On or about March 7, 2016- job site at 53-09 Marathon Parkway, Little Neck, NY 11362 an employee was using a DeWalt DWE 4011 grinder, to cut material, that had its blade guard removed. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19260451 B01 II |
Issuance Date |
2016-04-22 |
Abatement Due Date |
2016-05-04 |
Current Penalty |
1500.0 |
Initial Penalty |
2000.0 |
Final Order |
2016-06-09 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(1)(ii): The platform was not planked or decked as fully as possible and the remaining open space between the platform and the uprights exceeded 9.5 inches (24.1 cm): a) On or about March 7, 2016- job site at 53-09 Marathon Parkway, Little Neck, NY 11362 employees were working on a tubular welded framed scaffold that was not fully planked. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19260451 F07 |
Issuance Date |
2016-04-22 |
Abatement Due Date |
2016-05-04 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-06-09 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person: a) On or about March 7, 2016- job site at 53-09 Marathon Parkway, Little Neck, NY 11362 employees were working on a tubular welded framed scaffold that was assembled by employees without a competent present. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED. |
|
Citation ID |
01003C |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 |
Issuance Date |
2016-04-22 |
Abatement Due Date |
2016-05-04 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-06-09 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level. a) On or about March 7, 2016- job site at 53-09 Marathon Parkway, Little Neck, NY 11362 an employee was working on a tubular welded framed scaffold approximately 11 feet above the next lower level without fall protection. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2016-04-22 |
Abatement Due Date |
2016-05-04 |
Current Penalty |
0.0 |
Initial Penalty |
2000.0 |
Final Order |
2016-06-09 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about March 7, 2016- job site at 53-09 Marathon Parkway, Little Neck, NY 11362 an employee was working on a landing at a residential construction site, approximately 11 feet above the next lower level, without fall protection. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260405 A02 II I |
Issuance Date |
2016-04-22 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-06-09 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(a)(2)(ii)(I): Protection was not provided to avoid damage to flexible cords and cables used for temporary wiring which passed through doorways or other pinch points: a) On or about March 7, 2016- job site at 53-09 Marathon Parkway, Little Neck, NY 11362 an employee was using a DeWalt grinder that was being powered by a flexible cord set that was logged under a door, without protection from damage. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2016-04-22 |
Abatement Due Date |
2016-07-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-06-09 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program which at included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): (Construction Reference: 1926.59) a) On or about March 7, 2016- job site at 53-09 Marathon Parkway, Little Neck, NY 11362 employees of All City Stucco System Inc. were working with Energex, High Performance Wall Systems Stucco, without any Hazard Communication Program. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED. |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19101200 G08 |
Issuance Date |
2016-04-22 |
Abatement Due Date |
2016-07-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-06-09 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work shift to employees when they were in their work area(s): a) On or about March 7, 2016- job site at 53-09 Marathon Parkway, Little Neck, NY 11362 employees of All City Stucco System Inc. were working with Energex, High Performance Wall Systems Stucco, without maintaining workplace copies of the required safety data sheets. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED. |
|
Citation ID |
02004 |
Citaton Type |
Other |
Standard Cited |
19101200 H01 |
Issuance Date |
2016-04-22 |
Abatement Due Date |
2016-07-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-06-09 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (Construction Reference: 1926.59) a) On or about March 7, 2016- job site at 53-09 Marathon Parkway, Little Neck, NY 11362 employees of All City Stucco System Inc. were working with Energex, High Performance Wall Systems Stucco, without any Hazard Communication training. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED. |
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2013-07-19
|
Emphasis |
L: FALL
|
Case Closed |
2014-02-26
|
Related Activity
Type |
Referral |
Activity Nr |
834972 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
922942 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 B01 |
Issuance Date |
2013-09-19 |
Abatement Due Date |
2013-09-25 |
Current Penalty |
1000.0 |
Initial Penalty |
2000.0 |
Final Order |
2013-11-01 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): (a) At the Worksite - A tubular welded scaffold two level high was not fully planked; on or about 07/19/13. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN THE ACCORDANCE WITH 29 CFR 1903.19 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 E01 |
Issuance Date |
2013-09-19 |
Abatement Due Date |
2013-09-25 |
Current Penalty |
1000.0 |
Initial Penalty |
2000.0 |
Final Order |
2013-11-01 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. (a) At the worksite - Employees used the scaffold frame to access the working surface; on or about 07/19/13. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN THE ACCORDANCE WITH 29 CFR 1903.19 |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 |
Issuance Date |
2013-09-19 |
Abatement Due Date |
2013-09-25 |
Current Penalty |
1000.0 |
Initial Penalty |
2000.0 |
Final Order |
2013-11-01 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: (a) At the worksite - A tubular welded scaffold with a working surface 13 feet 5 inches above a concrete sidewalk did not have guardrails; on or about 07/19/13. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN THE ACCORDANCE WITH 29 CFR 1903.19 |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19260454 A |
Issuance Date |
2013-09-19 |
Abatement Due Date |
2013-10-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-11-01 |
Nr Instances |
3 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. (a) At the worksite - Employees were working from a tubular welded scaffold 13 feet 5 inches above a concrete sidewalk without fall protection, safe access and was not fully planked; on or about 07/19/13. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN THE ACCORDANCE WITH 29 CFR 1903.19 |
|
|