339050759
|
0215800
|
2013-04-30
|
111 WAVERLY AVE SYRACUSE UNIVERSITY DINEEN HALL - LAW COLLEGE, SYRACUSE, NY, 13201
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2013-04-30
|
Emphasis |
N: CTARGET, P: CTARGET
|
Case Closed |
2014-02-27
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19260350 A09 |
Issuance Date |
2013-06-26 |
Current Penalty |
0.0 |
Initial Penalty |
2310.0 |
Contest Date |
2013-07-22 |
Final Order |
2014-01-06 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.350(a)(9): Compressed gas cylinder(s) were not secured in an upright position: a) 3rd floor, steel lay down area, on or about 4/30/13: A cylinder of compressed Oxygen was stored in a horizontal position on the steel deck. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2013-06-26 |
Abatement Due Date |
2013-07-06 |
Current Penalty |
0.0 |
Initial Penalty |
3850.0 |
Contest Date |
2013-07-22 |
Final Order |
2014-01-06 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) At the jobsite, on or about 4/30/13: An employee was exposed to a fall of 15 feet to the next lower level. The employee was gathering fall protection equipment and rigging equipment. The employee was walking over breaks in the steel deck. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260502 B02 |
Issuance Date |
2013-06-26 |
Abatement Due Date |
2013-07-06 |
Current Penalty |
3850.0 |
Initial Penalty |
3850.0 |
Contest Date |
2013-07-22 |
Final Order |
2014-01-06 |
Nr Instances |
2 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(b)(2): Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structure members were not installed between the top edge of the guardrail system and the walking/working surface when there was no wall or parapet wall at least 21 inches (53 cm) high: a) At the site, 4th floor, on or about 4/30/13: There was no midrail provided in the guardrail system on the 4th floor over the 3rd floor steel lay down area. b) At the site, 6th floor, on or about 4/30/13: There was no midrail provided in the guardrail system on the 6th floor over the 5th floor. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260753 D01 |
Issuance Date |
2013-06-26 |
Abatement Due Date |
2013-07-06 |
Current Penalty |
0.0 |
Initial Penalty |
3850.0 |
Contest Date |
2013-07-22 |
Final Order |
2014-01-06 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.753(d)(1): Routes for suspended loads shall be pre-planned to ensure that no employee is required to work directly below a suspended load: a) At the jobsite, on or about 4/30/13: Employees were standing under the structural steel being bolted to the structure. The employees were not connecting the steel or required for the un-hooking of the load. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19260760 B01 |
Issuance Date |
2013-06-26 |
Abatement Due Date |
2013-07-06 |
Current Penalty |
0.0 |
Initial Penalty |
3850.0 |
Contest Date |
2013-07-22 |
Final Order |
2014-01-06 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.760(b)(1): Each connector was not protected in accordance with paragraphe (a)(1) of this section from fall hazards of more than two stories or 30 feet (9.1 m) above a lower level, whichever is less: a) At the jobsite, on or about 4/30/13: Two connectors enagaged in steel erection work were not protected from falling 37 feet to the ground below. |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19260760 B03 |
Issuance Date |
2013-06-26 |
Abatement Due Date |
2013-07-06 |
Current Penalty |
0.0 |
Initial Penalty |
3850.0 |
Contest Date |
2013-07-22 |
Final Order |
2014-01-06 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.760(b)(3): Each connector working at heights over 15 and up to 30 feet above a lower level, was not provided with a personal fall arrest system, positioning device system or fall restraint system and wear the equipment necessary to be able to be tied off; or was not provided with other means of protection from fall hazards in accordance with paragraph (a)(1) of this section: a) At the jobsite, on or about 4/30/13: A connector engaged in steel erection work was not provided with an anchorage point to complete the PFAS the employee needs to tie off while engaged in steel work. |
|
Citation ID |
01007 |
Citaton Type |
Serious |
Standard Cited |
19261424 A02 II |
Issuance Date |
2013-06-26 |
Current Penalty |
0.0 |
Initial Penalty |
3850.0 |
Contest Date |
2013-07-22 |
Final Order |
2014-01-06 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1424(a)(2)(ii): 29 CFR 1926.1424(a)(2)(ii): To prevent employees from entering hazard areas, the employer did not erect and maintain control lines, warning lines, railings or similar barriers to mark the boundaries of the hazard areas: a) At the jobsite, on or about 4/30/13: The swing radius of the LinkBelt 138 was not marked to prevent employees from entering the area. |
|
|
339011454
|
0215800
|
2013-04-17
|
FITZELLE HALL, SUNY ONEONTA, ONEONTA, NY, 13820
|
|
Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2013-04-17
|
Emphasis |
P: CTARGET, L: FALL, N: CTARGET
|
Case Closed |
2014-08-01
|
Related Activity
Type |
Inspection |
Activity Nr |
901138 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260754 E02 II |
Issuance Date |
2013-04-25 |
Abatement Due Date |
2013-05-10 |
Current Penalty |
0.0 |
Initial Penalty |
5390.0 |
Contest Date |
2013-05-15 |
Final Order |
2013-10-30 |
Nr Instances |
8 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.754(e)(2)(ii): 29 CFR 1926.754(e)(2)(ii): Roof and floor openings were not decked over and employees were not protected in accordance with 1926.760(a)(1): a) West end of building, clear story area, on or about 4-17-13: Three employees were working on a steel roof deck that had multiple openings that were not decked over, exposing the employees to a fall hazard of 23 feet 7 inches. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260754 E02 III |
Issuance Date |
2013-04-25 |
Abatement Due Date |
2013-05-10 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2013-05-15 |
Final Order |
2013-10-30 |
Nr Instances |
8 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.754(e)(2)(iii): Metal decking holes and openings were cut out and left in place until immediately prior to being permanently filled with the equipment or structure needed or intended to fulfill its specific use and which meets the strength requirements of paragraph (e)(3) of this section, or was not immediately covered: a) West end of building, clear story area, on or about 4-17-13: Three employees were working on a steel roof deck that had multiple openings that were not decked over and left open, exposing the employees to a fall hazard of 23 feet 7 inches. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260760 A01 |
Issuance Date |
2013-04-25 |
Current Penalty |
0.0 |
Initial Penalty |
5390.0 |
Contest Date |
2013-05-15 |
Final Order |
2013-10-30 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems: a) Southwest corner of building, clear story area, on or about 4-17-13: One employee was welding along the edge of a steel roof deck without fall protection, exposing the employee to a fall hazard of 49 feet. b) West side of building, clear story area, on or about 4-17-13: Three employees were working around deck openings without fall protection, exposing the employees to a fall hazard of 23 feet 7 inches. |
|
Citation ID |
01003 |
Citaton Type |
Other |
Standard Cited |
19261053 B01 |
Issuance Date |
2013-04-25 |
Current Penalty |
2400.0 |
Initial Penalty |
3080.0 |
Contest Date |
2013-05-15 |
Final Order |
2013-10-30 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) West side of building, northeast corner of clear story area, on or about 4-17-13: Employees were using a portable fiberglass extension ladder for access to a roof deck that was not extended 3 feet above the landing surface, exposing the employees to a fall hazard of 10 feet 9 inches. |
|
|
337363014
|
0215800
|
2012-11-14
|
107 HOY ROAD, ITHACA, NY, 14853
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2012-11-14
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2013-10-18
|
Related Activity
Type |
Referral |
Activity Nr |
677951 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19261053 B07 |
Issuance Date |
2013-02-05 |
Abatement Due Date |
2013-02-15 |
Current Penalty |
0.0 |
Initial Penalty |
4900.0 |
Contest Date |
2013-02-26 |
Final Order |
2013-08-23 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(7): Slip resistant feet were used as a substitute for care in placing, lashing, or holding a ladder that is used upon slippery surfaces, including, but not limited to, flat metal or concrete surfaces that are constructed so they cannot be prevented from becoming slippery. a) William Gates Hall, 107 Hoy Road - On or about 8 November, 2012 - Employees were setting up ladders with slip resistant feet on cold and wet metal slippery surfaces without exercising care in lashing or holding the ladder placed on the metal deck. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260760 A01 |
Issuance Date |
2013-02-05 |
Abatement Due Date |
2013-02-15 |
Current Penalty |
2695.0 |
Initial Penalty |
4900.0 |
Contest Date |
2013-02-26 |
Final Order |
2013-08-23 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems. a) William Gates Hall, Cornell University - On or about 9 November, 2012 - Employees were working in areas on and off ladders on the second floor exposed to unprotected sides or edges more than 15 feet above the next lower level. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19260754 E02 II |
Issuance Date |
2013-02-05 |
Abatement Due Date |
2013-02-15 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2013-02-26 |
Final Order |
2013-08-23 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.754(e)(2)(ii): Where roof and floor openings not decked over due to either large size, configuration or other structural design that does not allow openings to be decked over (such as elevator shafts, stair wells, etc.) Employees were not protected in accordance with 1926.760(a)(1). a) William Gates Hall, 107 Hoy Road - On or about 8 November, 2012 - Employees working on the second floor of the building were not protected from fall hazards while setting up ladders to perform work. |
|
|