Search icon

DONG & TANG INC

Company Details

Name: DONG & TANG INC
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 18 Jan 2011 (14 years ago)
Entity Number: 4043366
ZIP code: 10002
County: New York
Place of Formation: New York
Address: 54 HENRY STREET, #7, NEW YORK, NY, United States, 10002

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

Chief Executive Officer

Name Role Address
KIM B WONG Chief Executive Officer 54 HENRY STREET, #7, NEW YORK, NY, United States, 10002

DOS Process Agent

Name Role Address
GUODONG TANG & XUHUA DONG DOS Process Agent 54 HENRY STREET, #7, NEW YORK, NY, United States, 10002

History

Start date End date Type Value
2011-01-18 2022-05-04 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0

Filings

Filing Number Date Filed Type Effective Date
150121006458 2015-01-21 BIENNIAL STATEMENT 2015-01-01
110118000330 2011-01-18 CERTIFICATE OF INCORPORATION 2011-01-18

Inspections

Date Inspection Object Address Grade Type Institution Desctiption
2018-02-02 No data 80 STREET, FROM STREET 14 AVENUE TO STREET 15 AVENUE No data Street Construction Inspections: Post-Audit Department of Transportation Curb reset
2017-07-19 No data 80 STREET, FROM STREET 14 AVENUE TO STREET 15 AVENUE No data Street Construction Inspections: Post-Audit Department of Transportation Curb rest
2016-11-26 No data 6 STREET, FROM STREET 6 AVENUE TO STREET 7 AVENUE No data Street Construction Inspections: CAR Re-Inspect Department of Transportation joints sealed
2016-10-22 No data 157 STREET, FROM STREET 46 AVENUE TO STREET LABURNUM AVENUE No data Street Construction Inspections: Post-Audit Department of Transportation new sidewalk installed
2016-10-15 No data 6 STREET, FROM STREET 6 AVENUE TO STREET 7 AVENUE No data Street Construction Inspections: CAR Re-Inspect Department of Transportation A/T/P/O I observed the respondent Failed to seal expansion joints car issued on 6\3\16 #20166170070
2016-10-01 No data 80 STREET, FROM STREET 14 AVENUE TO STREET 15 AVENUE No data Street Construction Inspections: Post-Audit Department of Transportation curb ok
2016-06-03 No data 6 STREET, FROM STREET 6 AVENUE TO STREET 7 AVENUE No data Street Construction Inspections: Post-Audit Department of Transportation expansion joints need to be sealed
2016-05-08 No data 86 STREET, FROM STREET 23 AVENUE TO STREET BAY 32 STREET No data Street Construction Inspections: Post-Audit Department of Transportation Sidewalk in compliance.
2016-04-18 No data LUDLOW STREET, FROM STREET BROOME STREET TO STREET DELANCEY STREET No data Street Construction Inspections: CAR Re-Inspect Department of Transportation summons / hold / pass
2016-04-09 No data LUDLOW STREET, FROM STREET BROOME STREET TO STREET DELANCEY STREET No data Street Construction Inspections: CAR Re-Inspect Department of Transportation Failure to comply with DOT standard specifications. Full 5'x5' is required as per 34RCNY 2-09(f)(4)(vii). Respondent restored 10'x5' flags & partial flag. CAR 20155810559 was issued on 6/18/15, conditions remains.

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343209458 0215000 2018-06-06 752 41ST ST., BROOKLYN, NY, 11232
Inspection Type Planned
Scope NoInspection
Safety/Health Safety
Close Conference 2018-06-06
Emphasis P: LOCALTARG, L: LOCALTARG
Case Closed 2018-06-12
341099174 0215000 2015-11-30 764 METROPOLITAN AVENUE, BROOKLYN, NY, 11211
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2015-11-30
Emphasis L: FALL
Case Closed 2016-08-30

Related Activity

Type Referral
Activity Nr 1043641
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260020 B02
Issuance Date 2016-05-26
Abatement Due Date 2016-06-08
Current Penalty 2200.0
Initial Penalty 3080.0
Final Order 2016-06-28
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s). Site: 764 Metropolitan Avenue Brooklyn NY On or about 11/30/15 a) Frequent and regular inspections of the job site and equipment were not made by a competent person to identify and correct hazards and unsafe conditions.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260405 G02 IV
Issuance Date 2016-05-26
Abatement Due Date 2016-06-08
Current Penalty 1840.0
Initial Penalty 2640.0
Final Order 2016-06-28
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws. Site: 764 Metropolitan Avenue Brooklyn, NY On or about 11/30/15 a) Employees were using an orange extension cord to energize the cement mixer. The extension cord had broken strain relief.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260405 J01 II
Issuance Date 2016-05-26
Abatement Due Date 2016-06-08
Current Penalty 1020.0
Initial Penalty 1760.0
Final Order 2016-06-28
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(j)(1)(ii): Fixtures, lampholders, rosettes, or receptacles were not securely supported. Site: 764 Metropolitan Avenue Brooklyn, NY On or about 11/30/15 a) Receptacle used to energize power tools was not mounted or secured, It was supported by the electrical wires.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 G01 II
Issuance Date 2016-05-26
Abatement Due Date 2016-06-08
Current Penalty 2200.0
Initial Penalty 3080.0
Final Order 2016-06-28
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(ii): Each employee on a single-point or two-point adjustable suspension scaffold was not protected by both a personal fall arrest system and a guardrail system. Site: 764 Metropolitan Avenue Brooklyn, NY On or about 11/30/15 a) Employee working from a two pint suspended scaffold were exposed to a fall from approximately 70 feet high. The employees had their harness but were not tied off.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260451 D03 X
Issuance Date 2016-05-26
Abatement Due Date 2016-06-08
Current Penalty 2200.0
Initial Penalty 3080.0
Final Order 2016-06-28
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(d)(3)(x): Tiebacks were not installed perpendicular to the face of the building or structure, nor were opposing angle tiebacks installed. Site: 764 Metropolitan Avenue Brooklyn, NY On or about 11/30/15 a) Tiebacks were installed on a straight line and were not connected to the building structure.
Citation ID 01006
Citaton Type Serious
Standard Cited 19260451 G03 IV
Issuance Date 2016-05-26
Abatement Due Date 2016-06-08
Current Penalty 2200.0
Initial Penalty 3080.0
Final Order 2016-06-28
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(3)(iv): Vertical lifelines, independent support lines, and suspension ropes shall not be attached to each other, nor shall they be attached to or use the same point of anchorage, nor shall they be attached to the same point on the scaffold or personal fall arrest system. Site: 764 Metropolitan Avenue Brooklyn, NY On or about 11/30/15 a) Vertical lifelines and tiebacks were attached to the same anchorage point.
Citation ID 01007
Citaton Type Serious
Standard Cited 19261052 C01
Issuance Date 2016-05-26
Abatement Due Date 2016-06-08
Current Penalty 1840.0
Initial Penalty 2640.0
Final Order 2016-06-28
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail and one stairrail system along each unprotected side or edge. Site: 764 Metropolitan Avenue Brooklyn, NY On or about 11/30/15 a) Employees were exposed to fall hazards. Stairway being use to access their work area was missing the guardrails and handrails.
340920438 0215000 2015-09-15 350 DEGRAW ST., BROOKLYN, NY, 11231
Inspection Type FollowUp
Scope Complete
Safety/Health Safety
Close Conference 2015-09-15
Case Closed 2015-09-16

Related Activity

Type Inspection
Activity Nr 986609
Safety Yes
340921626 0215000 2015-09-15 8855 15TH AVE., BROOKLYN, NY, 11228
Inspection Type FollowUp
Scope Complete
Safety/Health Safety
Close Conference 2015-09-15
Case Closed 2015-09-16

Related Activity

Type Inspection
Activity Nr 988848
Safety Yes
339888489 0215000 2014-08-07 8855 15TH AVE, BROOKLYN, NY, 11228
Inspection Type Referral
Scope Complete
Safety/Health Safety
Close Conference 2014-08-08
Emphasis L: FALL
Case Closed 2016-08-25

Related Activity

Type Referral
Activity Nr 901948
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260404 B01 I
Issuance Date 2014-11-07
Abatement Due Date 2014-11-18
Current Penalty 1600.0
Initial Penalty 1600.0
Final Order 2015-07-08
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. a) 1st Floor Living Room: On or about August 7, 2014 An employee used a table saw which was plugged in by extension cord. The extension cord was not protected by GFI.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260404 F06
Issuance Date 2014-11-07
Abatement Due Date 2014-11-18
Current Penalty 1600.0
Initial Penalty 1600.0
Final Order 2015-07-08
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) First Floor Living Room: On or about August 7, 2014 Employees used a table saw which was missing its ground pin.
339866097 0215000 2014-07-25 350 DEGRAW ST, BROOKLYN, NY, 11231
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2014-08-08
Emphasis L: GUTREH, L: LOCALTARG, P: LOCALTARG
Case Closed 2018-08-29

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260404 F06
Issuance Date 2014-11-10
Abatement Due Date 2014-11-21
Current Penalty 1600.0
Initial Penalty 1600.0
Final Order 2015-07-08
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures was not permanent and continuous. a) Near DeGraw St. at the front of the site: On or about July 25, 2014 A laborer used a tamper which was plugged in by extension cord. The extension cord was missing the ground pin.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260405 G02 IV
Issuance Date 2014-11-10
Abatement Due Date 2014-11-19
Current Penalty 1600.0
Initial Penalty 1600.0
Final Order 2015-07-08
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: a) Near DeGraw St. at the front of the site: On or about July 25, 2014 A laborer used a tamper which was plugged in by extension cord. The plug of the extension cord was missing the strain relief.
Citation ID 02001
Citaton Type Other
Standard Cited 19260150 A04
Issuance Date 2014-11-10
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-07-08
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.150(a)(4): Defective firefighting equipment was not immediately replaced: a) front of site: On or about July 25, 2014 A fire extinguisher was undercharged but not removed from service.