343521159
|
0213600
|
2018-10-05
|
580 AUBURN AVENUE, BUFFALO, NY, 14222
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-10-05
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2019-03-22
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 I |
Issuance Date |
2018-10-25 |
Current Penalty |
1525.0 |
Initial Penalty |
2217.0 |
Final Order |
2018-11-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: a) On or about 10/05/18, at a 2-story house located at 580 Auburn Ave., Buffalo, NY: An employee was standing on the aluminum pic of a ladder jack scaffold erected on the west side of the house while replacing a facia board. The employee was exposed to a fall of approx. 16 ft. to the ground because no fall protection system was utilized. NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2018-10-25 |
Current Penalty |
1525.0 |
Initial Penalty |
2772.0 |
Final Order |
2018-11-02 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about 10/05/18, on the west side of the roof of a 2-story house located at 580 Auburn Ave., Buffalo, NY: Three employees engaged in roof sheeting work on a steep roof were exposed to a fall of approx. 18 foot. No fall protection system was utilized. The roof pitch was approx. 12 in 12. NO ABATEMENT CERTIFICATION REQUIRED |
|
|
342389624
|
0213600
|
2017-06-02
|
2460 HARLEM ROAD, CHEEKTOWAGA, NY, 14225
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-06-02
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2018-03-08
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B11 |
Issuance Date |
2017-09-21 |
Current Penalty |
1150.0 |
Initial Penalty |
1847.0 |
Final Order |
2017-10-12 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 06/02/17 at a roof replacement project located at 2460 Harlem Road, Cheektowaga, New York; employees working on the roof were placing shingles on the roof of a two story house. The roof had a 10 in 12 pitch and an eave heights of approximately 12 feet. There was no fall protection in use. NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2017-09-21 |
Current Penalty |
1150.0 |
Initial Penalty |
1847.0 |
Final Order |
2017-10-12 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On or about 06/02/17 at a roof replacement project located at 2460 Harlem Road, Cheektowaga, New York; an extension ladder used for access to the roof was only 1'-6" above the roof surface. NO ABATEMENT CERTIFICATION REQUIRED |
|
|