OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
334351939 0215000 2012-05-17 136 WAVERLY PLACE, NEW YORK, NY, 10014
Inspection Type Referral
Scope Complete
Safety/Health Safety
Close Conference 2012-05-17
Emphasis L: FALL
Case Closed 2018-03-13

Related Activity

Type Referral
Activity Nr 354386
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260300 B01
Issuance Date 2012-09-25
Current Penalty 2400.0
Initial Penalty 2400.0
Final Order 2012-10-22
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.300(b)(1): When power operated tools are designed to accommodate guards, they shall be equipped with such guards when in use. Site: 136 Waverly Place New York, NY On or about 5/17/12 a) The Bosch industrial grinder provided by the employer was missing the blade guard.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2012-09-25
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2012-10-22
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): "Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. Site: 136 Waverly Place New York, NY On or about 5/17/12 a) Employee workin/walking by the roof edge from approximately 11 feet high was exposed to fall hazards.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260503 C03
Issuance Date 2012-09-25
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2012-10-22
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(c)(3): Inadequacies in an affected employee's knowledge or use of fall protection systems or equipment indicate that the employee has not retained the requisite understanding or skill. Note: The following appendices to subpart M of this part serve as non-mandatory guidelines to assist employers in complying with the appropriate requirements of subpart M of this part. [59 FR 40738, Aug. 9, 1994; 60 FR 5131, Jan. 26, 1995] Site: 136 Waverly Place New York, NY On or about 5/17/12 a) Employee did not understand/recognized the hazards associated with the task being performed.