Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
331918995 | 0215800 | 2012-02-13 | 1055 EAST GENESEE ST, SYRACUSE, NY, 13205 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 191788 |
Safety | Yes |
Type | Inspection |
Activity Nr | 329107 |
Safety | Yes |
Type | Inspection |
Activity Nr | 191794 |
Safety | Yes |
Type | Inspection |
Activity Nr | 191797 |
Safety | Yes |
Type | Inspection |
Activity Nr | 191783 |
Safety | Yes |
Type | Inspection |
Activity Nr | 191933 |
Safety | Yes |
Type | Inspection |
Activity Nr | 191785 |
Safety | Yes |
Type | Inspection |
Activity Nr | 191781 |
Safety | Yes |
Type | Inspection |
Activity Nr | 191791 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B01 |
Issuance Date | 2012-05-18 |
Current Penalty | 3000.0 |
Initial Penalty | 3000.0 |
Final Order | 2012-06-26 |
Nr Instances | 2 |
Nr Exposed | 7 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(1): Each employee on a walking/working surface having an unprotected side or edge which was six or more feet (1.8m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest system: a) North side of the building, on or about 2/13/12: Employees were exposed to fall hazards of 9 feet 6 inches to grade without any means of fall protection. |
Citation ID | 01002A |
Citaton Type | Other |
Standard Cited | 19260502 B02 I |
Issuance Date | 2012-05-18 |
Current Penalty | 0.0 |
Initial Penalty | 3000.0 |
Final Order | 2012-06-26 |
Nr Instances | 3 |
Nr Exposed | 7 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.502(b)(2)(i): Midrails, when used, were not installed at a height midway between the top edge of the guardrail system and the walking/working level; screens and mesh, when used, did not extend from the top rail to the walking/working level and along the entire opening between top rail supports; Intermediate members, when used gbetween posts, were more than 19 inches (.5 m) apart; Other structural members were installed such that there are no openings in the guardrail system that are more than 19 inches (48 cm) wide: a) 1st floor, north end, Building "B", on or about 2/13/12: Midrails were not installed midway between the top edge and the floor. b) 2nd floor, north end, Building "B", on or about 2/13/12: Midrails were not installed midway between the top edge and the floor. c) 3rd floor, north end, Building "B", on or about 2/13/12: Midrails were not installed midway between the top edge and the floor. |
Citation ID | 01002B |
Citaton Type | Other |
Standard Cited | 19260502 B06 |
Issuance Date | 2012-05-18 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2012-06-26 |
Nr Instances | 1 |
Nr Exposed | 2 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.502(b)(6): Guardrail systems were not surfaced as to prevent injury to an employee from punctures or lacerations, and to prevent snagging of clothing: a) 3rd floor North end of Building "B", on or about 2/13/12: Guardrails were constructed so that the nails holding the rails to the uprights were facing out towards the employees working. |
Citation ID | 01003 |
Citaton Type | Other |
Standard Cited | 19260503 A01 |
Issuance Date | 2012-05-18 |
Abatement Due Date | 2012-06-04 |
Current Penalty | 0.0 |
Initial Penalty | 2400.0 |
Final Order | 2012-06-26 |
Nr Instances | 1 |
Nr Exposed | 7 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards: a) At the jobsite, on or about 2/13/12: Employees who were exposed to fall hazards were not provided with training to recognize and avoid fall hazards. |