Search icon

NORTHEAST LANDSCAPE & MASONRY ASSOCIATES, INC.

Company Details

Name: NORTHEAST LANDSCAPE & MASONRY ASSOCIATES, INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 16 Mar 2011 (14 years ago)
Entity Number: 4068269
ZIP code: 11228
County: Westchester
Place of Formation: New York
Address: 7014 13TH AVENUE, SUITE 202, BROOKLYN, NY, United States, 11228

Shares Details

Shares issued 2

Share Par Value 0.01

Type PAR VALUE

Agent

Name Role Address
UNITED STATES CORPORATION AGENTS, INC. Agent 7014 13TH AVENUE, SUITE 202, BROOKLYN, NY, 11228

DOS Process Agent

Name Role Address
C/O UNITED STATES CORPORATION AGENTS, INC. DOS Process Agent 7014 13TH AVENUE, SUITE 202, BROOKLYN, NY, United States, 11228

History

Start date End date Type Value
2011-03-16 2023-05-26 Shares Share type: PAR VALUE, Number of shares: 2, Par value: 0.01

Filings

Filing Number Date Filed Type Effective Date
110316000393 2011-03-16 CERTIFICATE OF INCORPORATION 2011-03-16

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339837429 0216000 2014-06-26 1 PARSONS ST., RYE, NY, 10580
Inspection Type Complaint
Scope Complete
Safety/Health Safety
Close Conference 2014-10-08
Case Closed 2019-08-21

Related Activity

Type Inspection
Activity Nr 984311
Safety Yes
Type Inspection
Activity Nr 984337
Safety Yes
Type Complaint
Activity Nr 897037
Safety Yes
Type Inspection
Activity Nr 983768
Safety Yes
Type Inspection
Activity Nr 983786
Safety Yes
Type Inspection
Activity Nr 983772
Safety Yes
Type Inspection
Activity Nr 983778
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 C02 II
Issuance Date 2014-10-10
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2014-11-12
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2)(ii): Unstable objects were used to support scaffolds or platform units: location: beside Parsons St. on or about: 6/26/14 a) Employees were engaged in masonry work from a tubular welded frame scaffold. The scaffold frames rested on masonry blocks.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2014-10-10
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2014-11-12
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used: location: interior penthouse on or about: 6/26/14 a) Employees working on a scaffold up to 9'10" above the lower level, were not provided with access. The employees climbed the walk through frames.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 F03
Issuance Date 2014-10-10
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2014-11-12
Nr Instances 3
Nr Exposed 6
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: location: entire site on or about: 6/26/14 a) A competent person did not inspect the scaffolds that were being used on site.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260451 G01
Issuance Date 2014-10-10
Current Penalty 5600.0
Initial Penalty 5600.0
Final Order 2014-11-12
Nr Instances 2
Nr Exposed 6
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level was not protected from falling to that lower level: location: beside Parsons St. on or about: 6/26/14 a) Employees, engaged in masonry work from a tubular welded frame scaffold, were not provided with fall protection. The employees were exposed to a fall of 14 feet 5 inches. location: penthouse - opposite Parsons St. on or about: 6/26/14 b) Employees, engaged in stonework from a tubular welded frame scaffold, were not provided with fall protection. The employees were exposed to a fall of 26 feet. Northeast Landscape was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 1926.451(g)(1), which was contained in OSHA inspection number 579561, citation number 1, item number 1 and was affirmed as a final order on 3/5/2013, with respect to a workplace located at 20 Orchard Drive, Tarrytown, NY.
339082679 0213100 2013-05-24 1132 MAIN STREET, FISHKILL, NY, 12524
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2013-05-29
Emphasis L: FALL
Case Closed 2014-04-11

Related Activity

Type Complaint
Activity Nr 820350
Safety Yes
Type Inspection
Activity Nr 908268
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2013-06-03
Abatement Due Date 2013-06-13
Current Penalty 0.0
Initial Penalty 2000.0
Contest Date 2013-06-07
Final Order 2014-02-07
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a) 1132 Main Street, Fishkill, NY - On and prior to May 22, 2013, employees were exposed to a fall hazard of approximately 20' to ground level when performing masonry work from prefabricated frame scaffolding that was not fully planked.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 B05 II
Issuance Date 2013-06-03
Abatement Due Date 2013-06-13
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2013-06-07
Final Order 2014-02-07
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(5)(ii): The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end: a) 1132 Main Street, Fishkill, NY - On and prior to May 22, 2013, employees were exposed a fall hazard of approximately 20' to ground level when performing masonry work from prefabricated frame scaffolding due to the platform ends extending over the supports up to 28" on the first, second and third levels.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2013-06-03
Abatement Due Date 2013-06-13
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2013-06-07
Final Order 2014-02-07
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee was not protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: a) 1132 Main Street, Fishkill, NY - On and prior to May 22, 2013, employees were exposed to a fall hazard of approximately 20' to ground level when performing masonry work from prefabricated frame scaffolding missing end and mid-guard railing.
Citation ID 01001D
Citaton Type Serious
Standard Cited 19260452 C02
Issuance Date 2013-06-03
Abatement Due Date 2013-06-13
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2013-06-07
Final Order 2014-02-07
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(c)(2): Tubular welded frame scaffold(s) were not properly braced by cross bracing or diagonal braces, or both, to secure vertical members laterally and to align them so that the erected scaffold was plumb, square, and rigid: a) 1132 Main Street, Fishkill, NY - On and prior to May 22, 2013, employees were exposed to a fall hazard of approximately 20' to ground level when performing masonry work from prefabricated frame scaffolding that did not have all cross bracing and some cross bracing was not secured to the vertical supports.
Citation ID 01001E
Citaton Type Serious
Standard Cited 19260452 C04
Issuance Date 2013-06-03
Abatement Due Date 2013-06-13
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2013-06-07
Final Order 2014-02-07
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(c)(4): End frames of tubular welded frame scaffolding were not locked together vertically by use of pins or equivalent means in areas where uplift could occur: a) 1132 Main Street, Fishkill, NY - On and prior to May 22, 2013, employees were exposed to a a fall hazard of approximately 18' to ground level when performing masonry work from prefabricated frame scaffolding that was missing a pin to lock tubular welded framing together. The scaffolding was subjected to uplift due to the use of a cantilever platform on the front side of the scaffolding.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2013-06-03
Abatement Due Date 2013-06-13
Current Penalty 0.0
Initial Penalty 2000.0
Contest Date 2013-06-07
Final Order 2014-02-07
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used: a) 1132 Main Street, Fishkill, NY - On and prior to May 22, 2013, employees were exposed to a fall hazard of approximately 20' to ground level when accessing a scaffolding that was not equipped with a ladder for access.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 F03
Issuance Date 2013-06-03
Abatement Due Date 2013-06-13
Current Penalty 0.0
Initial Penalty 2000.0
Contest Date 2013-06-07
Final Order 2014-02-07
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: a) 1132 Main Street, Fishkill, NY - On and prior to May 22, 2013, employees were exposed to fall hazards of approximately 20' to ground level when performing masonry work from prefabricated frame scaffolding that was not erected properly.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2013-06-03
Abatement Due Date 2013-06-13
Current Penalty 0.0
Initial Penalty 2000.0
Contest Date 2013-06-07
Final Order 2014-02-07
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: a) 1132 Main Street, Fishkill, NY - On and prior to May 22, 2013, for employees performing masonry work from prefabricated frame scaffolding; employees were not trained to recognize hazards associated with improperly erected scaffolding.

Motor Carrier Census

USDOT Number Carrier Operation MCS-150 Form Date MCS-150 Mileage MCS-150 Year Power Units Drivers Operation Classification
2419270 Intrastate Non-Hazmat 2013-07-03 - - 2 1 Private(Property)
Legal Name NORTHEAST LANDSCAPE & MASONRY ASSOCIATES INC
DBA Name -
Physical Address 3 W MAIN STREET SUITE 208, ELMSFORD, NY, 10523, US
Mailing Address 3 W MAIN STREET SUITE 208, ELMSFORD, NY, 10523, US
Phone (914) 381-0800
Fax -
E-mail -

Safety Measurement System - All Transportation

Total Number of Inspections for the measurement period (24 months) 0
Driver Fitness BASIC Serious Violation Indicator No
Vehicle Maintenance BASIC Acute/Critical Indicator No
Unsafe Driving BASIC Acute/Critical Indicator No
Driver Fitness BASIC Roadside Performance measure value 0
Hours-of-Service (HOS) Compliance BASIC Roadside Performance measure value 0
Total Number of Driver Inspections for the measurment period 0
Vehicle Maintenance BASIC Roadside Performance measure value 0
Total Number of Vehicle Inspections for the measurement period 0
Controlled Substances and Alcohol BASIC Roadside Performance measure value 0
Unsafe Driving BASIC Roadside Performance Measure Value 0
Number of inspections with at least one Driver Fitness BASIC violation 0
Number of inspections with at least one Hours-of-Service BASIC violation 0
Total Number of Driver Inspections containing at least one Driver Out-of-Service Violation 0
Number of inspections with at least one Vehicle Maintenance BASIC violation 0
Total Number of Vehicle Inspections containing at least one Vehicle Out-of-Service violation 0
Number of inspections with at least one Controlled Substances and Alcohol BASIC violation 0
Number of inspections with at least one Unsafe Driving BASIC violation 0

Date of last update: 27 Mar 2025