Search icon

SOUTHERN EXPRESS CONSTRUCTION CORP.

Company Details

Name: SOUTHERN EXPRESS CONSTRUCTION CORP.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 24 Mar 2011 (14 years ago)
Entity Number: 4072082
ZIP code: 10453
County: Bronx
Place of Formation: New York
Address: 1605 UNIVERSITY AVENUE, SUITE 3A, BRONX, NY, United States, 10453

Contact Details

Phone +1 347-997-2160

Shares Details

Shares issued 20000

Share Par Value 1

Type PAR VALUE

Agent

Name Role Address
SPIEGEL & UTRERA, P.A. P.C. Agent 1 MAIDEN LANE 5TH FLOOR, NEW YORK, NY, 10038

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 1605 UNIVERSITY AVENUE, SUITE 3A, BRONX, NY, United States, 10453

Licenses

Number Status Type Date End date
2093108-DCA Active Business 2019-12-19 2025-02-28

History

Start date End date Type Value
2023-07-21 2024-04-04 Shares Share type: PAR VALUE, Number of shares: 20000, Par value: 1
2023-07-13 2023-07-21 Shares Share type: PAR VALUE, Number of shares: 20000, Par value: 1
2011-03-24 2023-07-13 Shares Share type: PAR VALUE, Number of shares: 20000, Par value: 1

Filings

Filing Number Date Filed Type Effective Date
110324000330 2011-03-24 CERTIFICATE OF INCORPORATION 2011-03-24

Fine And Fees

Fee Sequence Id Fee type Status Date Amount Description
3598102 TRUSTFUNDHIC INVOICED 2023-02-14 200 Home Improvement Contractor Trust Fund Enrollment Fee
3598103 RENEWAL INVOICED 2023-02-14 100 Home Improvement Contractor License Renewal Fee
3316113 TRUSTFUNDHIC INVOICED 2021-04-07 200 Home Improvement Contractor Trust Fund Enrollment Fee
3316114 RENEWAL INVOICED 2021-04-07 100 Home Improvement Contractor License Renewal Fee
3123295 FINGERPRINT CREDITED 2019-12-05 75 Fingerprint Fee
3123044 FINGERPRINT INVOICED 2019-12-04 75 Fingerprint Fee
3123146 LICENSE INVOICED 2019-12-04 75 Home Improvement Contractor License Fee
3123045 TRUSTFUNDHIC INVOICED 2019-12-04 200 Home Improvement Contractor Trust Fund Enrollment Fee

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347538167 0216000 2024-06-10 629 COURTLANDT AVE., BRONX, NY, 10451
Inspection Type Fat/Cat
Scope Partial
Safety/Health Safety
Close Conference 2024-06-10
Emphasis N: FALL

Related Activity

Type Accident
Activity Nr 2172069
Type Inspection
Activity Nr 1753848
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B04 I
Issuance Date 2024-12-02
Abatement Due Date 2024-12-06
Current Penalty 6452.0
Initial Penalty 6452.0
Contest Date 2025-01-07
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Accident
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(4)(i):Each employee on walking/working surfaces was not protected from falling through holes (including skylights), more than six feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes. On or about: June 4, 2024 Location: 629 Courtlandt Ave., Bronx, NY 10451 Roof of new gym extension. a) One (1) worker was not provided with a personal fall arrest system (PFAS) and walked and worked on the corrugated roof deck and was exposed to unprotected floor hole, thereby exposing him to approximately 20-25-foot fall hazard.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260502 D11
Issuance Date 2024-12-02
Abatement Due Date 2024-12-06
Current Penalty 4610.0
Initial Penalty 4610.0
Contest Date 2025-01-07
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(d)(11): Lifelines were not protected against being cut or abraded. On or about: June 4, 2024 Location: 629 Courtlandt Ave., Bronx, NY 10451 Roof of new gym extension. a) Two (2) workers utilizing lifeline that was attached to a steel I-beam and was not protected from potential abrasions by corner of the I-beam.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260502 D16 III
Issuance Date 2024-12-02
Abatement Due Date 2024-12-06
Current Penalty 6452.0
Initial Penalty 6452.0
Contest Date 2025-01-07
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level. On or about: June 4, 2024 Location: 629 Courtlandt Ave., Bronx, NY 10451 Roof of new gym extension. a) Two (2) workers utilizing lifeline system that was not rigged to limit the free fall to not more than 6 feet. The lifelines were tied to an I-beam in the roof holes area and the length of the lifeline would allow an employee to fall more than 6 feet through multiple holes in the area.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2024-12-02
Abatement Due Date 2024-12-06
Current Penalty 4610.0
Initial Penalty 4610.0
Contest Date 2025-01-07
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Accident
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1):The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: On or about: June 4, 2024 Location: 629 Courtlandt Ave., Bronx, NY 10451 Roof of new gym extension. a) Three (3) workers who walked and worked on the corrugated roof deck and failed to recognize that they were exposed to unprotected floor hole, thereby exposing them to approximately 20-25-foot fall hazard.
Citation ID 02001
Citaton Type Other
Standard Cited 19040039 A02
Issuance Date 2024-12-02
Current Penalty 4610.0
Initial Penalty 4610.0
Contest Date 2025-01-07
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1904.39(a)(2): The employer did not report within 24-hours a work-related incident resulting in in-patient hospitalization, amputation or the loss of an eye. On or about: June 4, 2024 Location: 629 Courtlandt Ave., Bronx, NY 10451 Roof of gym extension a) Employer did not report in-patient hospitalization of the worker within 24 hours.