Search icon

MICHELLE CONSTRUCTION OF WESTCHESTER, INC

Company Details

Name: MICHELLE CONSTRUCTION OF WESTCHESTER, INC
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 06 Apr 2011 (14 years ago)
Entity Number: 4077905
ZIP code: 10573
County: Westchester
Place of Formation: New York
Address: 139 OAK STREET, PORT CHESTER, NY, United States, 10573

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 139 OAK STREET, PORT CHESTER, NY, United States, 10573

History

Start date End date Type Value
2011-04-06 2014-01-09 Address 138 OAK STREET, PORT CHESTER, NY, 10573, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
140109000829 2014-01-09 CERTIFICATE OF CHANGE 2014-01-09
110406000550 2011-04-06 CERTIFICATE OF INCORPORATION 2011-04-06

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
334281342 0216000 2012-05-04 383 SOUTH RIVERSIDE AVENUE CROTON-ON-HUDSON, CROTON ON HUDSON, NY, 10520
Inspection Type Complaint
Scope Complete
Safety/Health Safety
Close Conference 2012-05-04
Emphasis L: FALL, N: TRENCH
Case Closed 2019-08-21

Related Activity

Type Inspection
Activity Nr 443996
Safety Yes
Type Complaint
Activity Nr 349766
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 G01 VI
Issuance Date 2012-06-29
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2012-07-26
Nr Instances 2
Nr Exposed 2
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vi): Each employee performing overhand bricklaying operations from a supported scaffold was not protected from falling from all open sides and ends of the scaffold (except at the side next to the wall being laid) by the use of a personal fall arrest system or guardrail system (with minimum 200 pound toprail capacity). a) Employees hoisting materials from a scaffold platform 25 feet above the ground were not protected from falling as there was no mid rail. Observed on or about 04 May 2012. b) An employee was standing on an outrigger without fall protection. The outrigger was 25 Feet 8 inches above the ground. Observed on or about 04 May 2012.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2012-06-29
Abatement Due Date 2012-07-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-07-26
Nr Instances 1
Nr Exposed 7
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. (a) Employees were not trained to recognize and control hazards associated with pipe scaffolds. 383 South Riverside Avenue, Croton-on-Hudson, New York. Facade of builiding. Observed on or about 04 May 2012.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2012-06-29
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2012-07-26
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) Employee was nailing two two-by-four pieces of wood to the top of the parapet wall (24 inches) while standing just inside the wall, inches from the roof edge. Observed on or about 04 May 2012.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2012-06-29
Abatement Due Date 2012-07-23
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-07-26
Nr Instances 5
Nr Exposed 7
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards. a) Employees did not receive adequate training on the hazards of fall protection or procedures to follow in minimizing those hazards. 383 South Riverside Avenue, Croton-on-Hudson, NY. Observed on or about 04 May 2012.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260651 J02
Issuance Date 2012-06-29
Abatement Due Date 2012-07-23
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2012-07-26
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary. (a) Spoil pile was directly next to excavation and did not have sufficient clearance to prevent soil from falling back into excavation. Excavation was not protected from spoil pile by barriers or sloping. Rear of building under construction. Observed on or about 04 May 2012.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260651 K01
Issuance Date 2012-06-29
Abatement Due Date 2012-08-13
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2012-07-26
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems. (a) Employees entered a 7 foot deep by 30 foot long excavation that was not inspected by a competent person for evidence of a situation that could have resulted in possible cave-ins, or indications of failure of protective systems. 383 South Riverside Avenue, Croton-on-Hudson, New York rear of building. Observed on or about 04 May 2012.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260652 A01
Issuance Date 2012-06-29
Abatement Due Date 2012-07-23
Current Penalty 500.0
Initial Penalty 500.0
Final Order 2012-07-26
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c). The employer had not complied with the provisions of 29 CFR 1926.652(b)(1)(i) in that that did not provide protective measures such as shoring, sloping or benching of the excavation. (a) Employees erected a scaffold in an unprotected excavation 7 feet deep by 30 feet long. 383 South Riverside Avenue, Croton-on-Hudson, rear of building. Observed an unprotected trench on or about 04 May 2012.
Citation ID 01006
Citaton Type Serious
Standard Cited 19261052 C01
Issuance Date 2012-06-29
Current Penalty 1600.0
Initial Penalty 1600.0
Final Order 2012-07-26
Nr Instances 3
Nr Exposed 8
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail and one stairrail system along each unprotected side or edge: (a) Employees used stairwell from first to second floor with no handrails. Elevation from first level to second is 10 feet 10 and 3/4 inches. (b) Employees used stairwell from second floor to third floor with no handrails. Elevation from second level to third level is 9 feet 5 and 3/4 inches. (c) Employees used stairwell from first floor to basement with no handrails. Observed on or about 04 May 2012 at 383 South Riverside Avenue, Croton-on-Hudson, New York.

Date of last update: 27 Mar 2025

Sources: New York Secretary of State