Search icon

DIAMOND TECH PROPERTY DEVELOPMENT & CONSTRUCTION LLC

Company Details

Name: DIAMOND TECH PROPERTY DEVELOPMENT & CONSTRUCTION LLC
Jurisdiction: New York
Legal type: FOREIGN LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 06 Apr 2011 (14 years ago)
Entity Number: 4077972
ZIP code: 07307
County: New York
Place of Formation: New Jersey
Address: 266 GRIFFITH ST., SUITE 29, JERSEY CITY, NJ, United States, 07307

DOS Process Agent

Name Role Address
THE LLC DOS Process Agent 266 GRIFFITH ST., SUITE 29, JERSEY CITY, NJ, United States, 07307

Filings

Filing Number Date Filed Type Effective Date
130926000105 2013-09-26 CERTIFICATE OF PUBLICATION 2013-09-26
130404006624 2013-04-04 BIENNIAL STATEMENT 2013-04-01
110406000695 2011-04-06 APPLICATION OF AUTHORITY 2011-04-06

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339626988 0215000 2014-03-12 10 SOUTH STREET, NEW YORK, NY, 10004
Inspection Type Complaint
Scope Complete
Safety/Health Safety
Close Conference 2014-03-12
Emphasis L: FALL
Case Closed 2014-09-17

Related Activity

Type Complaint
Activity Nr 876253
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260300 B01
Issuance Date 2014-04-22
Current Penalty 1680.0
Initial Penalty 2400.0
Final Order 2014-05-16
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.300(b)(1): When power operated tools are designed to accommodate guards, they shall be equipped with such guards when in use. Site: 10 South Street New York, NY On or about 3/12/14 a) The Bosch grinder provided by the employer was missing the blade guard.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2014-04-22
Current Penalty 1960.0
Initial Penalty 2800.0
Final Order 2014-05-16
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): "Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. Site: 10 South Street New York, NY On or about 3/12/14 a) Employees working on the 4th to be were not provided with fall protection.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260501 B04 I
Issuance Date 2014-04-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-05-16
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces shall be protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes. Site: 10 South Street New York, NY On or about 3/12/14 a) Employer did not ensure that floor holes were protected. Employees were exposed to fall hazards from one floor to another.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19260503 C03
Issuance Date 2014-04-22
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-05-16
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(c)(3): Inadequacies in an affected employee's knowledge or use of fall protection systems or equipment indicate that the employee has not retained the requisite understanding or skill. Note: The following appendices to subpart M of this part serve as non-mandatory guidelines to assist employers in complying with the appropriate requirements of subpart M of this part. [59 FR 40738, Aug. 9, 1994; 60 FR 5131, Jan. 26, 1995] Site: 10 South Street New York, NY On or about 3/12/14 a) Employees did not understand/recognized the hazards associated with the task been performed. Fall protection re-training is required
Citation ID 01003
Citaton Type Serious
Standard Cited 19260850 A
Issuance Date 2014-04-22
Abatement Due Date 2014-05-02
Current Penalty 1960.0
Initial Penalty 2800.0
Final Order 2014-05-16
Nr Instances 1
Nr Exposed 9
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.850(a): Prior to permitting employees to start demolition operations, an engineering survey shall be made, by a competent person, of the structure to determine the condition of the framing, floors, and walls, and possibility of unplanned collapse of any portion of the structure. Any adjacent structure where employees may be exposed shall also be similarly checked. The employer shall have in writing evidence that such a survey has been performed. Site: 10 South Street New York, NY On or about 3/12/14 a) The employer did not provided a survey tha discusses the possibility of unplanned collapse of the wall been worked on.

Date of last update: 27 Mar 2025

Sources: New York Secretary of State