Search icon

GLOBAL GROUP INDUSTRIES CORPORATION

Company Details

Name: GLOBAL GROUP INDUSTRIES CORPORATION
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 18 May 2011 (14 years ago)
Entity Number: 4095898
ZIP code: 10002
County: New York
Place of Formation: New York
Address: 109 ELDRIDGE ST, STE S1, NEW YORK, NY, United States, 10002

Contact Details

Phone +1 646-633-2011

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
GLOBAL GROUP INDUSTRIES CORPORATION DOS Process Agent 109 ELDRIDGE ST, STE S1, NEW YORK, NY, United States, 10002

Chief Executive Officer

Name Role Address
TAN CHEUNG Chief Executive Officer 109 ELDRIDGE ST, STE S1, NEW YORK, NY, United States, 10002

Licenses

Number Status Type Date End date
1471238-DCA Inactive Business 2013-08-14 2019-02-28

History

Start date End date Type Value
2023-05-10 2023-11-09 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2022-10-26 2023-05-10 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2021-12-18 2022-10-26 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2021-07-26 2021-12-18 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2013-06-13 2017-05-02 Address 22 ORCHARD STREET BSMT, NEW YORK, NY, 10002, USA (Type of address: Principal Executive Office)
2013-06-13 2017-05-02 Address 22 ORCHARD STREET BSMT, NEW YORK, NY, 10002, USA (Type of address: Chief Executive Officer)
2011-05-18 2017-05-02 Address 22 ORCHARD STREET BSMT, NEW YORK, NY, 10002, 6109, USA (Type of address: Service of Process)
2011-05-18 2021-07-26 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0

Filings

Filing Number Date Filed Type Effective Date
170502006015 2017-05-02 BIENNIAL STATEMENT 2017-05-01
130613006013 2013-06-13 BIENNIAL STATEMENT 2013-05-01
110518000236 2011-05-18 CERTIFICATE OF INCORPORATION 2011-05-18

Inspections

Date Inspection Object Address Grade Type Institution Desctiption
2022-07-19 No data 88 AVENUE, FROM STREET 170 STREET TO STREET 171 STREET No data Street Construction Inspections: CAR Re-Inspect Department of Transportation C.A.R. re-inspection passed. Flags restored in front of 170-11 88th Avenue.
2020-03-18 No data 200 STREET, FROM STREET 34 AVENUE TO STREET 35 AVENUE No data Street Construction Inspections: Post-Audit Department of Transportation Curb - expansion joints sealed.
2020-01-14 No data 72 STREET, FROM STREET 16 AVENUE TO STREET 17 AVENUE No data Street Construction Inspections: Post-Audit Department of Transportation Curb installed, expansion joints sealed.
2019-08-04 No data PRESIDENT STREET, FROM STREET BOND STREET TO STREET HOYT STREET No data Street Construction Inspections: Post-Audit Department of Transportation curb work in compliance
2019-07-01 No data 216 STREET, FROM STREET 46 AVENUE TO STREET 47 AVENUE No data Street Construction Inspections: Post-Audit Department of Transportation Curb installed
2019-07-01 No data 46 AVENUE, FROM STREET 215 PLACE TO STREET 216 STREET No data Street Construction Inspections: Post-Audit Department of Transportation Curb repaired
2019-06-23 No data WITHERS STREET, FROM STREET HUMBOLDT STREET TO STREET WOODPOINT ROAD No data Street Construction Inspections: Post-Audit Department of Transportation Curb in compliance
2019-06-13 No data MERRICK BOULEVARD, FROM STREET 231 STREET TO STREET 232 STREET No data Street Construction Inspections: Post-Audit Department of Transportation new curb
2019-06-13 No data 232 STREET, FROM STREET 135 AVENUE TO STREET MERRICK BOULEVARD No data Street Construction Inspections: Post-Audit Department of Transportation curb
2019-06-12 No data 226 STREET, FROM STREET 69 AVENUE TO STREET 73 AVENUE No data Street Construction Inspections: Post-Audit Department of Transportation installed new curb

Complaints

Start date End date Type Satisafaction Restitution Result
2017-04-10 2017-05-10 Quality of Work No 0.00 Referred to Hearing

Fine And Fees

Fee Sequence Id Fee type Status Date Amount Description
2649464 LL VIO INVOICED 2017-07-31 500 LL - License Violation
2513399 RENEWAL INVOICED 2016-12-15 100 Home Improvement Contractor License Renewal Fee
2513398 TRUSTFUNDHIC INVOICED 2016-12-15 200 Home Improvement Contractor Trust Fund Enrollment Fee
1898073 TRUSTFUNDHIC INVOICED 2014-12-01 200 Home Improvement Contractor Trust Fund Enrollment Fee
1898074 RENEWAL INVOICED 2014-12-01 100 Home Improvement Contractor License Renewal Fee
1245146 LICENSE INVOICED 2013-08-14 100 Home Improvement Contractor License Fee
1245147 TRUSTFUNDHIC INVOICED 2013-08-13 200 Home Improvement Contractor Trust Fund Enrollment Fee

Issued Charges

Date Outcome Charge Charge count Counts sellted Counts guilty Counts not guilty
2017-12-11 Settlement (Pre-Hearing) NO/IMPROPER NOTICE OF CANCELLATION 1 1 No data No data
2017-12-11 Settlement (Pre-Hearing) NO OR IMPROPER BOND INFORMATION 1 1 No data No data
2017-12-11 Settlement (Pre-Hearing) IMPROPER TYPEFACE OR SIZE 1 1 No data No data
2017-12-11 Settlement (Pre-Hearing) CONTRACTOR DETAIL NOT IN CONTRACT 1 1 No data No data
2017-12-11 Settlement (Pre-Hearing) Failed to perform work in a skillful or competent manner. 1 1 No data No data
2017-12-11 Settlement (Pre-Hearing) NO OR IMPROPER PERMIT CLAUSE 1 1 No data No data
2017-12-11 Settlement (Pre-Hearing) NO/IMPROPER WORKMAN'S COMP CERTIFICATE 1 1 No data No data
2017-12-11 Settlement (Pre-Hearing) ABANDON/DEVIATE FROM CONTRACT 1 1 No data No data
2017-12-11 Settlement (Pre-Hearing) NO OR IMPROPER LIEN INFORMATION 1 1 No data No data
2017-12-11 Settlement (Pre-Hearing) NO OR IMPROPER DATES OF COMPLETION 1 1 No data No data

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341363323 0215600 2016-03-31 82-06 TYRON PLACE, JAMAICA, NY, 11432
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2016-03-31
Emphasis P: FALL, L: FALL

Related Activity

Type Referral
Activity Nr 1077098
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260095 A
Issuance Date 2016-04-22
Current Penalty 2200.0
Initial Penalty 2200.0
Contest Date 2016-05-12
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact: a) On or about March 31, 2016- job site of 82-06 Tyron Place, Jamaica, NY 11432 an employee was using a screw gun and screws to attach insulation to the side of a house without wearing eye protection. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 B01 II
Issuance Date 2016-04-22
Abatement Due Date 2016-05-04
Current Penalty 3080.0
Initial Penalty 3080.0
Contest Date 2016-05-12
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1)(ii): The platform was not planked or decked as fully as possible and the remaining open space between the platform and the uprights exceeded 9.5 inches (24.1 cm): a) On or about March 31, 2016- job site of 82-06 Tyron Place, Jamaica, NY 11432 two employees were working on a tubular welded frame scaffold that was not fully planked at the work level. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260451 C02 I
Issuance Date 2016-04-22
Abatement Due Date 2016-05-04
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2016-05-12
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2)(i): Footings were not level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement: a) On or about March 31, 2016- job site of 82-06 Tyron Place, Jamaica, NY 11432 two employees were working on a tubular welded frame scaffold that has its footing on piles of uneven and shifting soil. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2016-04-22
Abatement Due Date 2016-05-04
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2016-05-12
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used: a) On or about March 31, 2016- job site of 82-06 Tyron Place, Jamaica, NY 11432 two employees were working on a tubular welded frame scaffold that had no access ladder. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED.
Citation ID 01002D
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2016-04-22
Abatement Due Date 2016-05-04
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2016-05-12
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person: a) On or about March 31, 2016- job site of 82-06 Tyron Place, Jamaica, NY 11432 two employees were working on a tubular welded frame scaffold that was not erected by experienced employees under the supervision of a competent person. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED.
Citation ID 01002E
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2016-04-22
Abatement Due Date 2016-05-04
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2016-05-12
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) On or about March 31, 2016- job site of 82-06 Tyron Place, Jamaica, NY 11432 two employees were working on a tubular welded frame scaffold, approximately 15 feet above the next lower level, without fall protection. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED.
Citation ID 01002F
Citaton Type Serious
Standard Cited 19260452 C02
Issuance Date 2016-04-22
Abatement Due Date 2016-05-04
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2016-05-12
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(c)(2): Frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would secure vertical members together laterally, and the cross braces were not of such length as would automatically square: a) On or about March 31, 2016- job site of 82-06 Tyron Place, Jamaica, NY 11432 two employees were working on a tubular welded frame scaffold that was missing cross bracing on several sections of the scaffold. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED.

Date of last update: 27 Mar 2025