Search icon

FAST MECHANICS INC.

Company Details

Name: FAST MECHANICS INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 20 May 2011 (14 years ago)
Entity Number: 4097364
ZIP code: 11378
County: Queens
Place of Formation: New York
Address: 58-19 MASPETH AVE, MASPETH, NY, United States, 11378

Shares Details

Shares issued 100

Share Par Value 0.001

Type PAR VALUE

DOS Process Agent

Name Role Address
FABIO SALAZAR DOS Process Agent 58-19 MASPETH AVE, MASPETH, NY, United States, 11378

Filings

Filing Number Date Filed Type Effective Date
110520000786 2011-05-20 CERTIFICATE OF INCORPORATION 2011-05-20

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343439881 0215600 2018-09-05 93-45 SUTPHIN AVENUE, JAMAICA, NY, 11435
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2018-09-05
Emphasis L: FALL, L: GUTREH
Case Closed 2019-01-18

Related Activity

Type Inspection
Activity Nr 1260708
Safety Yes
342607082 0215600 2017-08-31 93-45 SUTPHIN AVE., JAMAICA, NY, 11435
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2017-08-31
Emphasis L: GUTREH, L: FALL
Case Closed 2022-09-09

Related Activity

Type Complaint
Activity Nr 1259627
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2018-02-15
Abatement Due Date 2018-02-22
Current Penalty 2772.0
Initial Penalty 2772.0
Final Order 2018-04-09
Nr Instances 2
Nr Exposed 2
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. (a) At the worksite - Employees manually demolishing a building were observed moving around on top of joists and a wall over 13 feet above the ground without fall protection; on or about 08/31/18. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN THE ACCORDANCE WITH 29 CFR 1903.19
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2018-02-15
Abatement Due Date 2018-03-07
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-04-09
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: (a) At the worksite - Employees manually demolishing a building were observed moving around on top of joists and a wall over 13 feet above the ground without fall protection; on or about 08/31/18. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN THE ACCORDANCE WITH 29 CFR 1903.19
Citation ID 01002
Citaton Type Serious
Standard Cited 19260502 I04
Issuance Date 2018-02-15
Current Penalty 1663.0
Initial Penalty 1663.0
Final Order 2018-04-09
Nr Instances 2
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(i)(4): All covers were not color coded or marked with the word "HOLE" or "COVER" to provide warning of the hazard: (a) At the worksite - Several holes in the floor covered by sheets of plywood were not color coded or marked; on or about 08/31/18.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2018-02-15
Abatement Due Date 2018-02-22
Current Penalty 2772.0
Initial Penalty 2772.0
Final Order 2018-04-09
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: (a) At the worksite - Employees manually demolishing a building used and A frame ladder that was too short to access a higher level that was over 13 feet above the ground; on or about 08/31/18. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN THE ACCORDANCE WITH 29 CFR 1903.19
Citation ID 01003B
Citaton Type Serious
Standard Cited 19261060 A
Issuance Date 2018-02-15
Abatement Due Date 2018-03-07
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-04-09
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards. (a) At the worksite - Employees manually demolishing a building used and A frame ladder that was too short to access a higher level that was over 13 feet above the ground; on or about 08/31/18. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN THE ACCORDANCE WITH 29 CFR 1903.19

Date of last update: 27 Mar 2025