Search icon

2347 WEST 1ST ST LLC

Company Details

Name: 2347 WEST 1ST ST LLC
Jurisdiction: New York
Legal type: DOMESTIC LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 07 Jun 2011 (14 years ago)
Entity Number: 4103796
ZIP code: 11223
County: Kings
Place of Formation: New York
Address: 1859 EAST 22ND STREET, BROOKLYN, NY, United States, 11223

DOS Process Agent

Name Role Address
THE LLC DOS Process Agent 1859 EAST 22ND STREET, BROOKLYN, NY, United States, 11223

Agent

Name Role Address
ALLSTATE CORPORATE SERVICES CORP. Agent ONE COMMERCE PLAZA, 99 WASHINGTON AVE. SUITE 1008, ALBANY, NY, 12260

History

Start date End date Type Value
2011-06-07 2012-03-13 Address ONE COMMERCE PLAZA, 99 WASHINGTON AVE. SUITE 1008, ALBANY, NY, 12260, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
220412002716 2022-04-12 BIENNIAL STATEMENT 2021-06-01
120313001222 2012-03-13 CERTIFICATE OF CHANGE 2012-03-13
111128000557 2011-11-28 CERTIFICATE OF PUBLICATION 2011-11-28
110607000866 2011-06-07 ARTICLES OF ORGANIZATION 2011-06-07

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345267553 0215000 2021-04-22 2051 E 13TH STREET, BROOKLYN, NY, 11229
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2021-04-22
Emphasis L: FALL, P: FALL
Case Closed 2022-03-25

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2021-10-18
Current Penalty 4096.0
Initial Penalty 4096.0
Final Order 2021-11-19
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii). Location: 2051 E 13th Street, Brooklyn, NY On or about: April 22, 2021 a) Employees worked from the 2nd level of the tubular welded frame scaffold and the scaffold platform was not fully planked.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2021-10-18
Current Penalty 4096.0
Initial Penalty 4096.0
Final Order 2021-11-19
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Location: 2051 E 13th Street, Brooklyn, NY On or about: April 22, 2021. (a) Employees working from a 3-tier high tubular welded frame scaffold which had no means of safe access. Employees climbed the frames and cross braces to access the work platforms.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2021-10-18
Current Penalty 4096.0
Initial Penalty 4096.0
Final Order 2021-11-19
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. Location: 2051 E 13th Street, Brooklyn, NY On or about: April 22, 2021 a) Employees worked from a 3-tier high tubular welded frame scaffold that was not fully planked, and was not equipped with guardrails and had no safe means of access. The scaffold was not erected under the supervision and direction of a competent person.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2021-10-18
Current Penalty 4096.0
Initial Penalty 4096.0
Final Order 2021-11-19
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. Location: 2051 E 13th Street, Brooklyn, NY On or about: April 22, 2021 a) Employees worked from a 3-tier high tubular welded frame scaffold without using any form of fall protection and exposed to falling approximately 12 feet to ground. Employees were standing on platform equipped with one or two planks and the scaffold was not equipped with guardrails or midrails.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2021-10-18
Current Penalty 4096.0
Initial Penalty 4096.0
Final Order 2021-11-19
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): Location: 2051 E 13th Street, Brooklyn, NY On or about: April 22, 2021 a) Employees worked from roof ledge without any means of fall protection, and were exposed to falling approximately 10 feet to ground.

Date of last update: 27 Mar 2025

Sources: New York Secretary of State