345317242
|
0216000
|
2021-05-19
|
BUTLER ROAD, SCARSDALE, NY, 10583
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2021-05-19
|
Emphasis |
L: FALL, P: FALL
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260102 A01 |
Issuance Date |
2021-05-21 |
Current Penalty |
3511.0 |
Initial Penalty |
3511.0 |
Final Order |
2021-07-01 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Imminent Danger |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents. A) Exterior, On the roof: Employees were exposed to eye/face injuries while using pneumatic nail guns and were not protected with any type of eye/face protection, on or about May 19th, 2021. NOTE: Because abatement of this violation is already documented in the inspection case file, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2021-05-21 |
Current Penalty |
3511.0 |
Initial Penalty |
3511.0 |
Final Order |
2021-07-01 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Imminent Danger |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): A) Roof of the structure: Employees were exposed to fall hazards of approximately 14 feet while engaged in siding work on the roof of a structure without a means of fall protection in place, on or about May 19th, 2021. NOTE: Because abatement of this violation is already documented in the inspection case file, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2021-05-21 |
Current Penalty |
3511.0 |
Initial Penalty |
3511.0 |
Final Order |
2021-07-01 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Imminent Danger |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: A) Exterior, Front of the house: Employees were exposed to fall hazards of approximately 14 feet while using an extension ladder that was not extended at least 3 feet over the landing that they were accessing, on or about May 19th, 2021. NOTE: Because abatement of this violation is already documented in the inspection case file, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19. |
|
|
339948572
|
0216000
|
2014-09-11
|
5 JOHANNA LANE, MONSEY, NY, 10952
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-09-11
|
Emphasis |
L: FALL
|
Case Closed |
2016-06-01
|
Related Activity
Type |
Complaint |
Activity Nr |
907932 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2014-10-06 |
Current Penalty |
1820.0 |
Initial Penalty |
2800.0 |
Final Order |
2014-10-17 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): On or about: 9/11/14 Location: 5 Johanna Lane, Monsey, NY 10952 a) Two employees performing roofing work on a 10 on 12 sloped roof and exposed to a 30' high fall hazard. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19261053 B16 |
Issuance Date |
2014-10-06 |
Current Penalty |
1040.0 |
Initial Penalty |
1600.0 |
Final Order |
2014-10-17 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired: On or about: 9/11/14 Location: 5 Johanna Lane, Monsey, NY 10952 a) Two employees used a 40 ft. Werner aluminum extension ladders to access a roof. The ladder had the 1st rung from the top and the 5th rung from the bottom damaged. |
|
|