Inspection Type |
Prog Other
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2022-05-25
|
Emphasis |
N: LEAD, P: LEAD
|
Case Closed |
2022-12-16
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260062 D01 I |
Issuance Date |
2022-10-31 |
Abatement Due Date |
2022-11-28 |
Current Penalty |
0.0 |
Initial Penalty |
2486.0 |
Final Order |
2022-11-25 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.62(d)(1)(i): The employer who had a workplace or operation covered by 29 CFR 1926.62 did not initially determine if any employees may be exposed to lead at or above the action level of 30 micrograms per cubic meter of air (30 ug/m3) calculated as an 8-hour time-weighted average (TWA): a) 895 Taughannock Blvd, Ithaca, NY, on or about May 1, 2022: Employees performed manual demolition of structure including but not limited to dry wall, painted walls and painted woodwork, manual scrapping and manual sanding, inside a property that was built in 1935, an assessment of employee exposure to lead was not performed. ABATEMENT CERTIFICATION MUST BE SUBMITTED FOR THIS ITEM |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260062 D01 III |
Issuance Date |
2022-10-31 |
Abatement Due Date |
2022-11-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2022-11-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.62(d)(1)(iii):The employer did not collect personal samples representative of a full shift, including at least one sample for each job classification in each work area, either for each shift or for the shift with the highest exposure level: a) 895 Taughannock Blvd, Ithaca, NY, on or about May 1, 2022: Employees performed manual demolition of structure including but not limited to dry wall, painted walls and painted woodwork, manual scrapping and manual sanding, inside a property that was built in 1935, the employer did not collect personal samples representative of a full shift. ABATEMENT CERTIFICATION MUST BE SUBMITTED FOR THIS ITEM |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260062 D02 V A |
Issuance Date |
2022-10-31 |
Abatement Due Date |
2022-11-28 |
Current Penalty |
0.0 |
Initial Penalty |
2486.0 |
Final Order |
2022-11-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.62(d)(2)(v)(A):Until the employer performed an employee exposure assessment as required under 29 CFR 1926.62(d) and determined actual employee exposure, the employer did not provide to employees performing the tasks described in 29 CFR 1926.62(d)(2)(i), (d)(2)(ii), (d)(2)(iii), and (d)(2)(iv) with appropriate respiratory protection in accordance with 29 CFR 1926.62(f): a) 895 Taughannock Blvd, Ithaca, NY, on or about May 1, 2022: Where employees performed manual demolition of structure including but not limited to dry wall, painted walls and painted woodwork, manual scrapping and manual sanding, inside a property that was built in 1935, an exposure assessment had not been performed, the employer did not provide employees with appropriate respiratory protection. ABATEMENT CERTIFICATION MUST BE SUBMITTED FOR THIS ITEM |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19260062 F02 I |
Issuance Date |
2022-10-31 |
Abatement Due Date |
2022-11-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2022-11-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.62(f)(2)(i):The employer did not implement a respiratory protection program in accordance with 29 CFR 1910.134(b) through (d) (except (d)(1)(iii)), and (f) through (m) for each employee required by 29 CFR 1926.62 to use a respirator: a) 895 Taughannock Blvd, Ithaca, NY, on or about May 1, 2022: A Respiratory Protection Program was not developed where employees using 3M 8210 filtering face piece half face respirators and/or 3M 6000 half face elastomeric respirators when performing manual demolition of structure including but not limited to dry wall, painted walls and painted woodwork, manual scrapping and manual sanding, inside a property that was built in 1935, and an exposure assessment had not been performed. ABATEMENT CERTIFICATION MUST BE SUBMITTED FOR THIS ITEM |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19260062 D02 V B |
Issuance Date |
2022-10-31 |
Abatement Due Date |
2022-11-28 |
Current Penalty |
0.0 |
Initial Penalty |
2486.0 |
Final Order |
2022-11-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.62(d)(2)(v)(B):Until the employer performed an employee exposure assessment as required under 29 CFR 1926.62(d) and determined actual employee exposure, the employer did not provide employees performing the tasks described in 29 CFR 1926.62(d)(2)(i), (d)(2)(ii), (d)(2)(iii), and (d)(2)(iv) with appropriate personal protective clothing and equipment in accordance with 29 CFR 1926.62(g): a) 895 Taughannock Blvd, Ithaca, NY, on or about May 1, 2022: Protective work clothing and equipment was not provided as an interim protection to employees who performed manual demolition of structure including but not limited to dry wall, painted walls and painted woodwork, manual scrapping and manual sanding, inside a property that was built in 1935, and an assessment had not been conducted to determine employee exposure to lead. ABATEMENT CERTIFICATION MUST BE SUBMITTED FOR THIS ITEM |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19260062 G01 |
Issuance Date |
2022-10-31 |
Abatement Due Date |
2022-11-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2022-11-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.62(g)(1):Where employees were exposed to lead above the permissible exposure limit, without regard to the use of respirators; where employees were exposed to lead compounds which may cause skin or eye irritation (e.g. lead arsenate, lead azide); and as interim protection for employees performing tasks as specified in 29 CFR 1926.62(d)(2), the employer did not provide at no cost to the employee and ensure that each employee used appropriate protective work clothing and equipment that prevented contamination of the employee and the employee's garments: a) 895 Taughannock Blvd, Ithaca, NY, on or about May 1, 2022: When an exposure assessment had not been performed, protective work clothing was not provided as interim protection to employees who performed manual demolition of structure including but not limited to dry wall, painted walls and painted woodwork, manual scrapping and manual sanding, inside a property that was built in 1935. ABATEMENT CERTIFICATION MUST BE SUBMITTED FOR THIS ITEM |
|
Citation ID |
01004A |
Citaton Type |
Serious |
Standard Cited |
19260062 D02 V C |
Issuance Date |
2022-10-31 |
Abatement Due Date |
2022-11-28 |
Current Penalty |
0.0 |
Initial Penalty |
2486.0 |
Final Order |
2022-11-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.62(d)(2)(v)(C):Until the employer performed an employee exposure assessment as required under 29 CFR 1926.62(d) and determined actual employee exposure, the employer did not provide to employees performing the tasks described in 29 CFR 1926.62(d)(2)(i), (d)(2)(ii), (d)(2)(iii), and (d)(2)(iv) with change areas in accordance with 29 CFR 1926.62(i)(2): a) 895 Taughannock Blvd, Ithaca, NY, on or about May 1, 2022: Change areas were not provided as an interim protection to employees who performed manual demolition of structure including but not limited to dry wall, painted walls and painted woodwork, manual scrapping and manual sanding, inside a property that was built in 1935, and an assessment had not been conducted to determine employee exposure to lead. ABATEMENT CERTIFICATION MUST BE SUBMITTED FOR THIS ITEM |
|
Citation ID |
01004B |
Citaton Type |
Serious |
Standard Cited |
19260062 I02 I |
Issuance Date |
2022-10-31 |
Abatement Due Date |
2022-11-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2022-11-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.62(i)(2)(i):The employer did not provide clean change areas for employees whose airborne exposure to lead was above the permissible exposure limit, without regard to the use of respirators: a) 895 Taughannock Blvd, Ithaca, NY, on or about May 1, 2022: Change areas were not provided as an interim protection to employees who performed manual demolition of structure including but not limited to dry wall, painted walls and painted woodwork, manual scrapping and manual sanding, inside a property that was built in 1935, and an assessment had not been conducted to determine employee exposure to lead. ABATEMENT CERTIFICATION MUST BE SUBMITTED FOR THIS ITEM |
|
Citation ID |
01005A |
Citaton Type |
Serious |
Standard Cited |
19260062 D02 V D |
Issuance Date |
2022-10-31 |
Abatement Due Date |
2022-11-28 |
Current Penalty |
0.0 |
Initial Penalty |
2486.0 |
Final Order |
2022-11-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.62(d)(2)(v)(D):Until the employer performed an employee exposure assessment as required under 29 CFR 1926.62(d) and determined actual employee exposure, the employer did not provide to employees performing the tasks described in 29 CFR 1926.62(d)(2)(i), (d)(2)(ii), (d)(2)(iii), and (d)(2)(iv) with hand washing facilities in accordance with 29 CFR 1926.62(i)(5): a) 895 Taughannock Blvd, Ithaca, NY, on or about May 1, 2022: Adequate hand washing facilities were not provided as an interim protection to employees who performed manual demolition of structure including but not limited to dry wall, painted walls and painted woodwork, manual scrapping and manual sanding, inside a property that was built in 1935, and an assessment had not been conducted to determine employee exposure to lead. ABATEMENT CERTIFICATION MUST BE SUBMITTED FOR THIS ITEM |
|
Citation ID |
01005B |
Citaton Type |
Serious |
Standard Cited |
19260062 I05 I |
Issuance Date |
2022-10-31 |
Abatement Due Date |
2022-11-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2022-11-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.62(i)(5)(i):The employer did not provide adequate handwashing facilities in accordance with 29 CFR 1926.51(f), for use by employees exposed to lead: a) 895 Taughannock Blvd, Ithaca, NY, on or about May 1, 2022: Adequate hand washing facilities were not provided to employees who performed manual demolition of structure including but not limited to dry wall, painted walls and painted woodwork, manual scrapping and manual sanding, inside a property that was built in 1935. ABATEMENT CERTIFICATION MUST BE SUBMITTED FOR THIS ITEM |
|
Citation ID |
01006A |
Citaton Type |
Serious |
Standard Cited |
19260062 D02 V E |
Issuance Date |
2022-10-31 |
Abatement Due Date |
2022-11-28 |
Current Penalty |
0.0 |
Initial Penalty |
2486.0 |
Final Order |
2022-11-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.62(d)(2)(v)(E):Until the employer performed an employee exposure assessment as required under 29 CFR 1926.62(d) and determined actual employee exposure, the employer did not provide to employees performing the tasks described in 29 CFR 1926.62(d)(2)(i), (d)(2)(ii), (d)(2)(iii), and (d)(2)(iv) with biological monitoring in accordance with 1926.62(j)(1)(i), to consist of blood sampling and analysis for lead and zinc protoporphyrin levels: a) 895 Taughannock Blvd, Ithaca, NY, on or about May 1, 2022: When an initial exposure assessment had not been conducted, employees who performed manual demolition of structure including but not limited to dry wall, painted walls and painted woodwork, manual scrapping and manual sanding, inside a property that was built in 1935, did not make biological monitoring available. ABATEMENT CERTIFICATION MUST BE SUBMITTED FOR THIS ITEM |
|
Citation ID |
01006B |
Citaton Type |
Serious |
Standard Cited |
19260062 J01 I |
Issuance Date |
2022-10-31 |
Abatement Due Date |
2022-11-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2022-11-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.62(j)(1)(i):The employer did not make available initial medical surveillance, consisting of biological monitoring in the form of blood sampling and analysis for lead and zinc protoporphyrin levels, to employees occupationally exposed on any day to lead at or above the action level: a) 895 Taughannock Blvd, Ithaca, NY, on or about May 1, 2022: Where employees performed manual demolition of structure including but not limited to dry wall, painted walls and painted woodwork, manual scrapping and manual sanding, inside a property that was built in 1935, and an initial exposure assessment had not been conducted, initial medical surveillance, in the form of biological monitoring/blood sampling was not made available. ABATEMENT CERTIFICATION MUST BE SUBMITTED FOR THIS ITEM |
|
Citation ID |
01007A |
Citaton Type |
Other |
Standard Cited |
19260062 D02 V F |
Issuance Date |
2022-10-31 |
Abatement Due Date |
2022-11-28 |
Current Penalty |
0.0 |
Initial Penalty |
2486.0 |
Final Order |
2022-11-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.62(d)(2)(v)(F):Until the employer performed an employee exposure assessment as required under 29 CFR 1926.62(d) and determined actual employee exposure, the employer did not provide to employees performing the tasks described in 29 CFR 1926.62(d)(2)(i), (d)(2)(ii), (d)(2)(iii), and (d)(2)(iv) with training as required under 29 CFR 1926.62(l)(1)(i) regarding 29 CFR 1926.59, Hazard Communication: a) 895 Taughannock Blvd, Ithaca, NY, on or about May 1, 2022: When an exposure assessment had not been conducted, employees who performed manual demolition of structure including but not limited to dry wall, painted walls and painted woodwork, manual scrapping and manual sanding, inside a property that was built in 1935, were not provided with training on lead. ABATEMENT CERTIFICATION MUST BE SUBMITTED FOR THIS ITEM |
|
Citation ID |
01007B |
Citaton Type |
Other |
Standard Cited |
19260062 L01 I |
Issuance Date |
2022-10-31 |
Abatement Due Date |
2022-11-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2022-11-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.62(l)(1)(i):Hazard communication. The employer did not include lead in the program established to comply with the Hazard Communication Standard (HCS) (� 1910.1200). The employer did not ensure that each employee was trained in accordance with the provisions of HCS and paragraph (l) of this section. a) 895 Taughannock Blvd, Ithaca, NY, on or about May 1, 2022: When an exposure assessment had not been conducted, employees who performed manual demolition of structure including but not limited to dry wall, painted walls and painted woodwork, manual scrapping and manual sanding, inside a property that was built in 1935, were not provided with training on lead. ABATEMENT CERTIFICATION MUST BE SUBMITTED FOR THIS ITEM |
|
Citation ID |
01007C |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2022-10-31 |
Abatement Due Date |
2022-11-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2022-11-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace, a written hazard communication program which at least describes how the criteria specified in 29 CFR 1910.1200 (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met: (Construction Reference 1926.59) a) 895 Taughannock Blvd, Ithaca, NY, on or about May 1, 2022: A written Hazard Communication Program was not developed where employees were exposed to hazardous substances, including, but not limited to lead, inside a property that was built in 1935. ABATEMENT CERTIFICATION MUST BE SUBMITTED FOR THIS ITEM |
|
|