Name: | SEJINL 2011 CORP. |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Inactive |
Date of registration: | 08 Jul 2011 (14 years ago) |
Date of dissolution: | 31 Aug 2016 |
Entity Number: | 4116161 |
ZIP code: | 11729 |
County: | Suffolk |
Place of Formation: | New York |
Address: | 107 WOODLAWN AVENUE, DEER PARK, NY, United States, 11729 |
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Name | Role | Address |
---|---|---|
THE CORPORATION | DOS Process Agent | 107 WOODLAWN AVENUE, DEER PARK, NY, United States, 11729 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
DP-2199350 | 2016-08-31 | DISSOLUTION BY PROCLAMATION | 2016-08-31 |
110708000522 | 2011-07-08 | CERTIFICATE OF INCORPORATION | 2011-07-08 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
335680583 | 0215000 | 2012-08-10 | 148 E. 48TH ST, NEW YORK, NY, 10017 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 568200 |
Safety | Yes |
Type | Inspection |
Activity Nr | 567138 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260300 B01 |
Issuance Date | 2012-09-26 |
Current Penalty | 800.0 |
Initial Penalty | 1600.0 |
Final Order | 2012-11-19 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.300(b)(1): When power operated tools are designed to accommodate guards, they shall be equipped with such guards when in use. a) 10th Floor Southwest bathroom near the corner of building: On or about August 10, 2012 A tile installer was using a grinder to install tiles. The grnder guard was not attached. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260404 F06 |
Issuance Date | 2012-09-26 |
Current Penalty | 800.0 |
Initial Penalty | 4000.0 |
Final Order | 2012-11-19 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous. a) 10th Floor Southwest bathroom near the corner of building: On or about August 10, 2012 An employee used a grinder which was plugged in by extension cord. The extension cord was missing the ground pin. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260404 B01 I |
Issuance Date | 2012-09-26 |
Current Penalty | 800.0 |
Initial Penalty | 1600.0 |
Final Order | 2012-11-19 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.404(b)(1)(i): General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors. a) 10th Floor Southwest bathroom near the corner of building: On or about August 10, 2012 An employee used a grinder which was plugged in by extension cord. The extension cord was not protected by GFCI. |
Date of last update: 27 Mar 2025
Sources: New York Secretary of State