OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
335680583 0215000 2012-08-10 148 E. 48TH ST, NEW YORK, NY, 10017
Inspection Type Unprog Rel
Scope Complete
Safety/Health Safety
Close Conference 2012-08-10
Case Closed 2012-11-19

Related Activity

Type Inspection
Activity Nr 568200
Safety Yes
Type Inspection
Activity Nr 567138
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260300 B01
Issuance Date 2012-09-26
Current Penalty 800.0
Initial Penalty 1600.0
Final Order 2012-11-19
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.300(b)(1): When power operated tools are designed to accommodate guards, they shall be equipped with such guards when in use. a) 10th Floor Southwest bathroom near the corner of building: On or about August 10, 2012 A tile installer was using a grinder to install tiles. The grnder guard was not attached.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260404 F06
Issuance Date 2012-09-26
Current Penalty 800.0
Initial Penalty 4000.0
Final Order 2012-11-19
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous. a) 10th Floor Southwest bathroom near the corner of building: On or about August 10, 2012 An employee used a grinder which was plugged in by extension cord. The extension cord was missing the ground pin.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260404 B01 I
Issuance Date 2012-09-26
Current Penalty 800.0
Initial Penalty 1600.0
Final Order 2012-11-19
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(b)(1)(i): General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors. a) 10th Floor Southwest bathroom near the corner of building: On or about August 10, 2012 An employee used a grinder which was plugged in by extension cord. The extension cord was not protected by GFCI.