344420260
|
0214700
|
2019-10-29
|
20 BAY ST., SAG HARBOR, NY, 11963
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2019-10-29
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2021-02-08
|
Related Activity
Type |
Inspection |
Activity Nr |
1442031 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1442013 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2020-04-28 |
Abatement Due Date |
2020-05-04 |
Current Penalty |
1800.0 |
Initial Penalty |
2892.0 |
Final Order |
2020-09-23 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Worksite, 20 Bay St., Sag Harbor, NY- Employee was installing shingles to the roof of a residence style building approximately 20 feet above the next level. The employee was not protected from falling by guardrail systems, safety net systems or personal fall arrest systems; on or about 10/29/19. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19260503 B01 |
Issuance Date |
2020-04-28 |
Abatement Due Date |
2020-05-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2020-09-23 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(b)(1): The employer did not verify fall protection training by preparing a written certification record a) Worksite, 20 Bay St., Sag Harbor, NY- Employees were installing shingles to the roof of a residence approximately 20 feet above the next level. Employees were not protected from falling by guardrail systems, safety net systems or personal fall arrest systems. The employer told the CSHO he provided training to recognize fall hazards but did not have a written certification record; on or about 10/29/19. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
|
|
342759743
|
0214700
|
2017-11-07
|
20 WYANDANCH LANE, SOUTHAMPTON, NY, 11968
|
|
Inspection Type |
FollowUp
|
Scope |
NoInspection
|
Safety/Health |
Safety
|
Close Conference |
2017-11-07
|
Case Closed |
2017-11-07
|
Related Activity
Type |
Inspection |
Activity Nr |
1192884 |
Safety |
Yes |
|
|
341928844
|
0214700
|
2016-11-18
|
20 WYANDANCH LANE, SOUTHAMPTON, NY, 11969
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2016-11-18
|
Emphasis |
P: FALL, L: FALL
|
Case Closed |
2018-11-16
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260100 A |
Issuance Date |
2017-04-27 |
Abatement Due Date |
2017-05-03 |
Current Penalty |
1793.0 |
Initial Penalty |
1793.0 |
Final Order |
2017-05-30 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) Worksite: Employees working directly under ongoing siding and window work were not using head protection; on or about 11/18/16. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260451 C02 II |
Issuance Date |
2017-04-27 |
Abatement Due Date |
2017-05-03 |
Current Penalty |
4183.0 |
Initial Penalty |
4183.0 |
Final Order |
2017-05-30 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(c)(2)(ii): Unstable objects were used to support scaffolds or platform units: a) Worksite: Folding ladders placed in an unstable manner on the roof of the first story were used to mount the ladder jack scaffold; on or about 11/18/17. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19261053 B04 |
Issuance Date |
2017-04-27 |
Abatement Due Date |
2017-05-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-05-30 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) Worksite: Folding ladders were used to mount a ladder jack scaffold platform; on or about 11/18/16. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260451 E01 |
Issuance Date |
2017-04-27 |
Abatement Due Date |
2017-05-03 |
Current Penalty |
2988.0 |
Initial Penalty |
2988.0 |
Final Order |
2017-05-30 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used: a) Worksite: Employees were doing siding and window work from a ladder jack scaffold, approximately 14 ft. above the ground and were not provided with an access ladder or similar surface; on or about 11/18/16. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 I |
Issuance Date |
2017-04-27 |
Abatement Due Date |
2017-05-03 |
Current Penalty |
4183.0 |
Initial Penalty |
4183.0 |
Final Order |
2017-05-30 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: a) Worksite: Employees doing window and siding work from a ladder jack scaffold approximately 14 ft. above the ground were not protected from falling; on or about 11/18/16. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19261053 B05 I |
Issuance Date |
2017-04-27 |
Abatement Due Date |
2017-05-03 |
Current Penalty |
1793.0 |
Initial Penalty |
1793.0 |
Final Order |
2017-05-30 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder: a) Worksite: Employees were using a ladder to access the roof of the residential building that was used at an angle such that the ratio between the horizontal distance from the top support to the foot of the ladder was approximately one to one; on or about 11/18/16. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
|
|
340138866
|
0214700
|
2014-12-15
|
671 HALSEY LANE, BRIDGEHAMPTON, NY, 11932
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-12-15
|
Emphasis |
L: FALL
|
Case Closed |
2016-06-02
|
Related Activity
Type |
Inspection |
Activity Nr |
1014350 |
Safety |
Yes |
|
Type |
Referral |
Activity Nr |
927170 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2015-06-12 |
Abatement Due Date |
2015-06-18 |
Current Penalty |
2800.0 |
Initial Penalty |
2800.0 |
Final Order |
2015-07-10 |
Nr Instances |
1 |
Nr Exposed |
8 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Worksite, 671 Halsey Lane, Bridgehampton, NY- Employees were installing shingles to the roof of a residence approximately 20 feet above the next level. Employees were not protected from falling by guardrail systems, safety net systems or personal fall arrest systems; on or about 12/15/14 Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260502 B02 |
Issuance Date |
2015-06-12 |
Abatement Due Date |
2015-06-18 |
Current Penalty |
2800.0 |
Initial Penalty |
2800.0 |
Final Order |
2015-07-10 |
Nr Instances |
1 |
Nr Exposed |
8 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(b)(2): Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structure members were not installed between the top edge of the guardrail system and the walking/working surface when there was no wall or parapet wall at least 21 inches (53 cm) high. a) Worksite, roof- Employees engaged in roofing activities were working on the second level deck of a residential construction. The edge of the deck, approximately 10 feet above the ground below had a top rail but no midrail; on or about 12/15/14. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260503 A01 |
Issuance Date |
2015-06-12 |
Abatement Due Date |
2015-06-24 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Final Order |
2015-07-10 |
Nr Instances |
1 |
Nr Exposed |
8 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) Worksite, roof- Employees engaged in roofing activities were working on the roof and at the roof edge of a residential construction approximately 9 to 26 feet above levels below. Employees did not receive training to recognize fall hazards; on or about 12/15/15. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
|
|