Search icon

LEVEL ONE BUILDERS, INC.

Company Details

Name: LEVEL ONE BUILDERS, INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 08 Jul 2011 (14 years ago)
Entity Number: 4116176
ZIP code: 11354
County: Queens
Place of Formation: New York
Address: 143-08 ROOSEVELT AVE, #502, FLUSHING, NY, United States, 11354

Contact Details

Phone +1 646-229-2323

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 143-08 ROOSEVELT AVE, #502, FLUSHING, NY, United States, 11354

Chief Executive Officer

Name Role Address
MIN HYUNG LEE Chief Executive Officer 143-08 ROOSEVELT AVE, #502, FLUSHING, NY, United States, 11354

Licenses

Number Status Type Date End date
1470931-DCA Inactive Business 2013-08-08 2015-02-28

History

Start date End date Type Value
2011-07-08 2013-07-23 Address 143-08 ROOSEVELT AVE., APT. #502, FLUSHING, NY, 11354, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
170607006085 2017-06-07 BIENNIAL STATEMENT 2015-07-01
130723002061 2013-07-23 BIENNIAL STATEMENT 2013-07-01
110708000547 2011-07-08 CERTIFICATE OF INCORPORATION 2011-07-08

Fine And Fees

Fee Sequence Id Fee type Status Date Amount Description
1248538 LICENSE INVOICED 2013-08-08 100 Home Improvement Contractor License Fee
1248537 TRUSTFUNDHIC INVOICED 2013-08-08 200 Home Improvement Contractor Trust Fund Enrollment Fee
1248539 FINGERPRINT INVOICED 2013-08-08 75 Fingerprint Fee

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340140433 0215600 2014-12-16 252-28 LEITH ROAD, LITTLE NECK, NY, 11362
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2014-12-16
Emphasis L: FALL
Case Closed 2015-03-02

Related Activity

Type Referral
Activity Nr 927305
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260403 B02
Issuance Date 2014-12-30
Abatement Due Date 2015-01-27
Current Penalty 1000.0
Initial Penalty 2000.0
Final Order 2015-01-26
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) On or about December 16, 2014, job site at 252-28 Leith Road, Little Neck, NY 11362: Employer permitted their employees to use an electrical outlet box, that is designed to be mounted on a wall, as a re-locatable power strip. WRTTEN ABATEMENT CERTIFICATION IS REQUIRED
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260405 G02 III
Issuance Date 2014-12-30
Abatement Due Date 2015-01-27
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-01-26
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(g)(2)(iii): Flexible cords were not used in continuous lengths without splice or tap: a) On or about December 16, 2014, job site at 252-28 Leith Road, Little Neck, NY 11362: Employer permitted their employees to use an energized flexible cord to operate power tools that had been improperly spliced. WRTTEN ABATEMENT CERTIFICATION IS REQUIRED
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260404 B01 II
Issuance Date 2014-12-30
Abatement Due Date 2015-01-27
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-01-26
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection: a) On or about December 16, 2014, job site at 252-28 Leith Road, Little Neck, NY 11362: Employer permitted their employees to use electrical powered hand tools that without Ground Fault Circuit Interrupter protection. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B02 II
Issuance Date 2014-12-30
Abatement Due Date 2015-01-27
Current Penalty 1000.0
Initial Penalty 2000.0
Final Order 2015-01-26
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(2)(ii): Each employee on a walking/working surface 6 feet (1.8 m) or more above a lower level where leading edges are under construction, but who was not engaged in the leading edge work, was not protected from falling by a guardrail system, safety net system, or personal fall arrest system.Note: If a guardrail system was chosen to provide the fall protection, and a controlled access zone had already been established for leading edge work, the control line may be used in lieu of a guardrail along the edge that parallels the leading edge. a) On or about December 16, 2014, job site at 252-28 Leith Road, Little Neck, NY 11362: Employer permitted their employees to work near a large floor opening, over 7 feet to the next lowest level, without any fall protection. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED
Citation ID 01003A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2014-12-30
Abatement Due Date 2015-01-27
Current Penalty 1000.0
Initial Penalty 2000.0
Final Order 2015-01-26
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about December 16, 2014, job site at 252-28 Leith Road, Little Neck, NY 11362: Employer permitted their employees to work on the second floor of a residential construction site, 9 feet, 6 inches above the next lowest level, without any fall protection. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED
Citation ID 01003B
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2014-12-30
Abatement Due Date 2015-01-27
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-01-26
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) On or about December 16, 2014, job site at 252-28 Leith Road, Little Neck, NY 11362: Employer permitted their employees to work on the second floor of a residential construction site, 9 feet, 6 inches above the next lowest level, without any fall protection training. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED

Date of last update: 27 Mar 2025

Sources: New York Secretary of State