Search icon

DAVID VINCENT WOODWORK, LLC

Company Details

Name: DAVID VINCENT WOODWORK, LLC
Jurisdiction: New York
Legal type: DOMESTIC LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 04 Aug 2011 (14 years ago)
Entity Number: 4126415
ZIP code: 10464
County: Bronx
Place of Formation: New York
Address: 551 CITY ISLAND AVENUE, BRONX, NY, United States, 10464

DOS Process Agent

Name Role Address
THE LLC DOS Process Agent 551 CITY ISLAND AVENUE, BRONX, NY, United States, 10464

Agent

Name Role Address
DAVID VINCENT Agent 551 CITY ISLAND AVENUE, BRONX, NY, 10464

Filings

Filing Number Date Filed Type Effective Date
120221000259 2012-02-21 CERTIFICATE OF PUBLICATION 2012-02-21
110804000049 2011-08-04 ARTICLES OF ORGANIZATION 2011-08-04

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344620265 0216000 2020-02-11 551 CITY ISLAND AVENUE, BRONX, NY, 10464
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2020-02-11
Emphasis L: NOISE, N: AMPUTATE, P: NOISE
Case Closed 2024-02-20

Related Activity

Type Inspection
Activity Nr 1461477
Health Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100147 C01
Issuance Date 2020-03-27
Abatement Due Date 2020-04-15
Current Penalty 1440.0
Initial Penalty 4048.0
Contest Date 2020-04-23
Final Order 2020-10-16
Nr Instances 3
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: Location: 551 City Island Ave Bronx NY 10464 a) On or about February 11, 2020, an employee was exposed to caught in hazards while servicing and/or maintenance of the three machines due to no Lock Out Tag Out Program.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19100213 C03
Issuance Date 2020-03-27
Abatement Due Date 2020-04-08
Current Penalty 1440.0
Initial Penalty 4048.0
Contest Date 2020-04-23
Final Order 2020-10-16
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: Location: 551 City Island Ave Bronx NY 10464 a) On or about February 11, 2020, an employee was exposed to caught in hazards while cutting or ripping wood using a table saw - Otto Martin Maschinebau Type 72 Serial No. V 148763 Year 1987.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19100213 D01
Issuance Date 2020-03-27
Abatement Due Date 2020-04-08
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2020-04-23
Final Order 2020-10-16
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.213(d)(1): Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: Location: 551 City Island Ave Bronx NY 10464 a) On or about February 11, 2020, an employee was exposed to caught in hazards while cross cutting or ripping wood using a table saw due to the blade not having a hood which encloses the blade - Otto Martin Maschinebau Type 72 Serial No. V 148763 Year 1987.
344614771 0216000 2020-02-04 551 CITY ISLAND AVENUE, BRONX, NY, 10464
Inspection Type Planned
Scope Complete
Safety/Health Health
Close Conference 2020-02-11
Emphasis L: NOISE, P: NOISE

Related Activity

Type Inspection
Activity Nr 1462026
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100134 C01
Issuance Date 2020-03-27
Abatement Due Date 2020-05-01
Current Penalty 614.0
Initial Penalty 1735.0
Contest Date 2020-04-23
Final Order 2020-09-01
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a) Shop Area: Employees cutting hardwood (e.g. maple) with mechanical saws were required to wear N95 filtering facepiece respirators and the employer did not develop and implement a written respiratory protection program; on or about 2/11/20.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100134 E01
Issuance Date 2020-03-27
Abatement Due Date 2020-05-01
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2020-04-23
Final Order 2020-09-01
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) Shop Area: Employees cutting hardwood (e.g. maple) with mechanical saws were required to wear N95 filtering facepiece respirators and the employer did not provide a medical evaluation for employees; on or about 2/11/20.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19101200 E01
Issuance Date 2020-03-27
Abatement Due Date 2020-05-01
Current Penalty 1006.0
Initial Penalty 2892.0
Contest Date 2020-04-23
Final Order 2020-09-01
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following: a) Shop Area: Employees were exposed to hazardous chemicals when cutting hardwoods (e.g., maple) and building cabinets using Bondo Body Filler (styrene) and the employer did not develop and implement a written hazard communication program; on or about 2/4/20.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19101200 G01
Issuance Date 2020-03-27
Abatement Due Date 2020-05-01
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2020-04-23
Final Order 2020-09-01
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use: a) Shop Area: Employees were exposed to hazardous chemicals when cutting hardwoods (e.g., maple) and building cabinets using Bondo Body Filler (styrene) and the employer did not obtain a safety data sheet for these hazardous chemicals; on or about 2/11/20.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19101200 H01
Issuance Date 2020-03-27
Abatement Due Date 2020-05-01
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2020-04-23
Final Order 2020-09-01
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) Shop Area: Employees were exposed to hazardous chemicals when cutting hardwoods (e.g., maple) and building cabinets using Bondo Body Filler (styrene) and the employer did not provide training on the hazardous chemicals; on or about 2/11/20.
Citation ID 02001
Citaton Type Other
Standard Cited 19100037 B02
Issuance Date 2020-03-27
Abatement Due Date 2020-05-01
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2020-04-23
Final Order 2020-09-01
Nr Instances 2
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.37(b)(2): Each exit must be clearly visible and marked by a sign reading "Exit." a) Entire Building: The front and rear exit doors were not marked by signs reading "Exit"; on or about 2/11/20.
Citation ID 02002
Citaton Type Other
Standard Cited 19100037 B04
Issuance Date 2020-03-27
Abatement Due Date 2020-05-01
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2020-04-23
Final Order 2020-09-01
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent: a) Middle Room - Unused storage: Signs were not posted in this room indicating the direction of travel to the nearest exit; on or about 2/11/20.

Date of last update: 26 Mar 2025

Sources: New York Secretary of State