Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2022-08-12
|
Case Closed |
2023-08-04
|
Related Activity
Type |
Complaint |
Activity Nr |
1792354 |
Health |
Yes |
|
Type |
Complaint |
Activity Nr |
1910735 |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100151 C |
Issuance Date |
2022-09-28 |
Abatement Due Date |
2023-02-17 |
Current Penalty |
1989.0 |
Initial Penalty |
3315.0 |
Final Order |
2023-01-17 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.151(c):Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a) Laundry Room, Sun Hotels Brewerton LLC, Brewerton, NY. - On or about 6/29/2022, an eyewash was not available for employees working with corrosive chemicals including, but not limited to, Foamy Q&A containing phosphoric acid; Clothesline Fresh Alkaline Spotter containing potassium hydroxide; Clothesline Fresh Chlorinated Bleach containing sodium hypochlorite. Abatement certification must be submitted for this item |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100133 A01 |
Issuance Date |
2022-09-28 |
Abatement Due Date |
2022-10-13 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-01-17 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.133(a)(1): Protective eye equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment: a) Laundry Room, Sun Hotels Brewerton LLC, Brewerton, NY. - On or about 6/29/2022, eye protection including, but not limited to, splash goggles were not available nor worn by employees working with corrosive chemicals including, but not limited to, Foamy Q&A containing phosphoric acid; Clothesline Fresh Alkaline Spotter containing potassium hydroxide; Clothesline Fresh Chlorinated Bleach containing sodium hypochlorite. Abatement certification must be submitted for this item |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100138 A |
Issuance Date |
2022-09-28 |
Abatement Due Date |
2022-10-13 |
Current Penalty |
0.0 |
Initial Penalty |
2486.0 |
Final Order |
2023-01-17 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes: a) Laundry Room, Sun Hotels Brewerton LLC, Brewerton, NY. - On or about 6/29/2022, hand protection including, but not limited to, chemical resistant gloves were available but employer did not require employees to wear gloves while employees were working with corrosive chemicals including, but not limited to, Foamy Q&A containing phosphoric acid; Clothesline Fresh Alkaline Spotter containing potassium hydroxide; Clothesline Fresh Chlorinated Bleach containing sodium hypochlorite. Abatement certification must be submitted for this item |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19101200 E01 |
Issuance Date |
2022-09-28 |
Abatement Due Date |
2022-10-13 |
Current Penalty |
0.0 |
Initial Penalty |
3315.0 |
Final Order |
2023-01-17 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): Employer did not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): a) Laundry Room, Sun Hotels Brewerton LLC, Brewerton, NY. - On or about 6/29/2022, a Hazard Communication Program was not developed and implemented for employees working with hazardous chemicals including, but not limited to, corrosives and severe irritants such as Foamy Q&A containing phosphoric acid; Clothesline Fresh Alkaline Spotter containing potassium hydroxide; Clothesline Fresh Chlorinated Bleach containing sodium hypochlorite. Abatement certification must be submitted for this item |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19101200 H01 |
Issuance Date |
2022-09-28 |
Abatement Due Date |
2022-10-13 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-01-17 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) Laundry Room, Sun Hotels Brewerton LLC, Brewerton, NY. - On or about 6/29/2022, Hazard Communication information and training was not developed and implemented for employees working with hazardous chemicals including, but not limited to, corrosives and severe irritants such as Foamy Q&A containing phosphoric acid; Clothesline Fresh Alkaline Spotter containing potassium hydroxide; Clothesline Fresh Chlorinated Bleach containing sodium hypochlorite. Abatement certification must be submitted for this item |
|
|