Name: | SINATRA & COMPANY REAL ESTATE LLC |
Jurisdiction: | New York |
Legal type: | FOREIGN LIMITED LIABILITY COMPANY |
Status: | Active |
Date of registration: | 17 Aug 2011 (14 years ago) |
Entity Number: | 4131965 |
ZIP code: | 14203 |
County: | Erie |
Place of Formation: | Delaware |
Address: | 617 MAIN STREET, SUITE 200, BUFFALO, NY, United States, 14203 |
Name | Role | Address |
---|---|---|
SINATRA & COMPANY REAL ESTATE LLC | DOS Process Agent | 617 MAIN STREET, SUITE 200, BUFFALO, NY, United States, 14203 |
Number | Type | End date |
---|---|---|
10301217228 | ASSOCIATE BROKER | 2025-02-07 |
10491208962 | LIMITED LIABILITY BROKER | 2025-02-07 |
10991218165 | REAL ESTATE PRINCIPAL OFFICE | No data |
10401203732 | REAL ESTATE SALESPERSON | 2026-07-13 |
Start date | End date | Type | Value |
---|---|---|---|
2016-01-26 | 2023-08-23 | Address | 617 MAIN STREET, SUITE 200, BUFFALO, NY, 14203, USA (Type of address: Service of Process) |
2011-08-17 | 2016-01-26 | Address | 3350 DELAWARE AVENUE, TONAWANDA, NY, 14217, USA (Type of address: Service of Process) |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
230823001884 | 2023-08-23 | BIENNIAL STATEMENT | 2023-08-01 |
220628000589 | 2022-06-28 | BIENNIAL STATEMENT | 2021-08-01 |
190805060768 | 2019-08-05 | BIENNIAL STATEMENT | 2019-08-01 |
180716006369 | 2018-07-16 | BIENNIAL STATEMENT | 2017-08-01 |
160126006208 | 2016-01-26 | BIENNIAL STATEMENT | 2015-08-01 |
130913002237 | 2013-09-13 | BIENNIAL STATEMENT | 2013-08-01 |
120404000561 | 2012-04-04 | CERTIFICATE OF PUBLICATION | 2012-04-04 |
110817000793 | 2011-08-17 | APPLICATION OF AUTHORITY | 2011-08-17 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
336037395 | 0213600 | 2012-08-06 | 945 W. FERRY STREET, BUFFALO, NY, 14210 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001A |
Citaton Type | Other |
Standard Cited | 19101200 E01 |
Issuance Date | 2012-08-31 |
Abatement Due Date | 2012-10-30 |
Current Penalty | 0.0 |
Initial Penalty | 1200.0 |
Final Order | 2012-09-24 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (Construction Reference: 1926.59) a) The Fenton, 945 W. Ferry Street, no program had been developed or implemented for the employees exposed to materials such as but not limited to gasoline and latex paint. ABATEMENT CERTIFICATION REQUIRED |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19101200 G08 |
Issuance Date | 2012-08-31 |
Abatement Due Date | 2012-09-15 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2012-09-24 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.1200(g)(8): The employer did not maintain copies of the required material safety data sheets for each hazardous chemical in the workplace: (Construction Reference: 1926.59) a) The Fenton, 945 W. Ferry Street, no material safety data sheets were provided or made available to the employees for materials such as but not limited to latex paint and gasoline. ABATEMENT CERTIFICATION REQUIRED |
Citation ID | 01001C |
Citaton Type | Serious |
Standard Cited | 19101200 H01 |
Issuance Date | 2012-08-31 |
Abatement Due Date | 2012-09-15 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2012-09-24 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (Construction Reference: 1926.59) a) The Fenton, 945 W. Ferry Street, no training was provided for the employees potentially exposed to materials such as but not limited to gasoline and latex paint. ABATEMENT CERTIFICATION REQUIRED |
Citation ID | 01003A |
Citaton Type | Serious |
Standard Cited | 19260503 A01 |
Issuance Date | 2012-08-31 |
Abatement Due Date | 2012-09-15 |
Current Penalty | 2000.0 |
Initial Penalty | 2000.0 |
Final Order | 2012-09-24 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) The Fenton, 945 W. Ferry Street, employees had not been given any training in the proper use of fall protection as evidenced by the type of lanyard being used, the attachment point on the aerial lift, and the attachment point of the lanyard on the user's body. ABATEMENT CERTIFICATION REQUIRED |
Citation ID | 01003B |
Citaton Type | Serious |
Standard Cited | 19260502 D15 |
Issuance Date | 2012-08-31 |
Current Penalty | 0.0 |
Initial Penalty | 2000.0 |
Final Order | 2012-09-24 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Referral |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person: a) The Fenton, 945 W. Ferry Street, the two (2) foot nylon lanyard was wrapped around the toprail of the basket on the Genie Aerial Lift and the guardrail is not capable of supporting 5000 pounds per employee as required, the lift manufacturers only rate the strength of the guardrail system for 300 pounds. NO ABATEMENT CERTIFICATION REQUIRED |
Citation ID | 01003C |
Citaton Type | Serious |
Standard Cited | 19260502 D16 II |
Issuance Date | 2012-08-31 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2012-09-24 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Referral |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.502 (d)(16)(ii): Personal fall arrest systems, when stopping a fall, did not limit the maximum arresting force on an employee to 1800 pounds (8kn) when used with a body harness: a) The Fenton, 945 W. Ferry Street, two (2) foot nylon lanyard being used with a harness did not have a shock-absorber included in the length of the lanyard to limit the arresting force. NO ABATEMENT CERTIFICATION REQUIRED |
Citation ID | 01003D |
Citaton Type | Serious |
Standard Cited | 19260502 D17 |
Issuance Date | 2012-08-31 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2012-09-24 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.502(d)(17): The attachment point of the body harness was not located in the center of the wearer's back near shoulder level, or above the wearer's head: a) The Fenton, 345 W. Ferry Street, the two (2) foot nylon lanyard used to tie-off around the guardrail system of the lift was attached to a "D" ring that was located in the center of the employees chest. NO ABATEMENT CERTIFICATION REQUIRED |