Name: | AVSTAR FUEL SYSTEMS, INC. |
Jurisdiction: | New York |
Legal type: | FOREIGN BUSINESS CORPORATION |
Status: | Active |
Date of registration: | 23 Aug 2011 (14 years ago) |
Branch of: | AVSTAR FUEL SYSTEMS, INC., Florida (Company Number P07000046822) |
Entity Number: | 4134084 |
ZIP code: | 33458 |
County: | Cayuga |
Place of Formation: | Florida |
Address: | C/O ELLEN D'ARCANGELO, 1365 PARK LANE SOUTH, JUPITER, FL, United States, 33458 |
Principal Address: | 1365 PARK LANE SOUTH, JUPITER, FL, United States, 33458 |
Name | Role | Address |
---|---|---|
THE CORPORATION | DOS Process Agent | C/O ELLEN D'ARCANGELO, 1365 PARK LANE SOUTH, JUPITER, FL, United States, 33458 |
Name | Role | Address |
---|---|---|
RONALD J WEAVER | Chief Executive Officer | 1365 PARK LANE S, JUPITER, FL, United States, 33458 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
130805006569 | 2013-08-05 | BIENNIAL STATEMENT | 2013-08-01 |
110823000990 | 2011-08-23 | APPLICATION OF AUTHORITY | 2011-08-23 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
338949563 | 0215800 | 2013-03-12 | 15 BROOKFIELD PLACE, AUBURN, NY, 13021 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100157 G02 |
Issuance Date | 2013-03-22 |
Abatement Due Date | 2013-04-26 |
Current Penalty | 1000.0 |
Initial Penalty | 2100.0 |
Contest Date | 2013-04-15 |
Final Order | 2013-07-19 |
Nr Instances | 1 |
Nr Exposed | 25 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter: a) Avstar Fuel Systems, Inc., on or about 3/12/13: Training on the use of fire extinguishers and the hazards associated with incipient stage fire fighting was not provided to employees at least annually. *ABATEMENT NOTE: By this date the employer must either correct the alleged violation or implement a Fire Safety Policy; as outlined in 29 CFR 1910.38(a) and .39(a) which includes the evacuation requirements of 29 CFR 1910.157(b). |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19100212 A01 |
Issuance Date | 2013-03-22 |
Abatement Due Date | 2013-04-16 |
Current Penalty | 1250.0 |
Initial Penalty | 2800.0 |
Contest Date | 2013-04-15 |
Final Order | 2013-07-19 |
Nr Instances | 3 |
Nr Exposed | 13 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) CNC Area, on or about 3/12/13: Baldor buffing machine was not provided with a guard over the rotating shaft and nut on the left side. b) CNC Area, on or about 3/12/13: Bridgeport milling machine was not provided with a chuck and tool guard. c) CNC Area, on or about 3/12/13: Jet single spindle drill press was not provided with a chuck and tool guard. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19100242 B |
Issuance Date | 2013-03-22 |
Abatement Due Date | 2013-04-01 |
Current Penalty | 1250.0 |
Initial Penalty | 2800.0 |
Contest Date | 2013-04-15 |
Final Order | 2013-07-19 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i: a) Debur Area, on or about 3/12/13: Employees were cleaning metal parts using compressed air nozzles that delivered air pressures greater than 30 p.s.i. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19100134 K06 |
Issuance Date | 2013-03-22 |
Abatement Due Date | 2013-04-01 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Contest Date | 2013-04-15 |
Final Order | 2013-07-19 |
Nr Instances | 1 |
Nr Exposed | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer: a) Deburring Area, on or about 3/12/13: Employees who voluntarily wear N95 filtering facepieces when deburring metal parts were not provided with the information on respirators contained in Appendix D of the respirator standard. |
Status | User ID | Name of Firm | Trade Name | UEI | Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Active | P3226253 | AVSTAR FUEL SYSTEMS, INC | - | LTSFSAXARGA8 | 15 BROOKFIELD PL, AUBURN, NY, 13021-2209 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
HUBZone Certified | No |
Women Owned Certified | No |
Women Owned Pending | No |
Economically Disadvantaged Women Owned Certified | No |
Economically Disadvantaged Women Owned Pending | No |
Veteran-Owned Small Business Certified | No |
Veteran-Owned Small Business Joint Venture | No |
Service-Disabled Veteran-Owned Small Business Certified | No |
Service-Disabled Veteran-Owned Small Business Joint Venture | No |
Bonding Levels
Description | Construction Bonding Level (per contract) |
Level | (none given) |
Description | Construction Bonding Level (aggregate) |
Level | (none given) |
Description | Service Bonding Level (per contract) |
Level | (none given) |
Description | Service Bonding Level (aggregate) |
Level | (none given) |
NAICS Codes with Size Determinations by NAICS
Primary | Yes |
Code | 332710 |
NAICS Code's Description | Machine Shops |
Buy Green | Yes |
Code | 336412 |
NAICS Code's Description | Aircraft Engine and Engine Parts Manufacturing |
Buy Green | Yes |
Export Profile (Trade Mission Online)
Exporter | Firm hasn't answered this question yet |
Export Business Activities | (none given) |
Exporting to | (none given) |
Desired Export Business Relationships | (none given) |
Description of Export Objective(s) | (none given) |
Date of last update: 26 Mar 2025
Sources: New York Secretary of State