Inspections

Date Inspection Object Address Grade Type Institution Desctiption
2013-07-31 No data MORRIS AVENUE, FROM STREET CAMERON PLACE TO STREET EAST 182 STREET No data Street Construction Inspections: Post-Audit Department of Transportation No data
2012-11-21 No data WALTON AVENUE, FROM STREET CAMERON PLACE TO STREET EAST 182 STREET No data Street Construction Inspections: Post-Audit Department of Transportation No data
2012-08-29 No data VALENTINE AVENUE, FROM STREET BEDFORD PARK BOULEVARD TO STREET EAST 201 STREET No data Street Construction Inspections: Post-Audit Department of Transportation No data
2012-07-27 No data MORRIS AVENUE, FROM STREET CAMERON PLACE TO STREET EAST 182 STREET No data Street Construction Inspections: Post-Audit Department of Transportation No data
2012-07-13 No data MORRIS AVENUE, FROM STREET CAMERON PLACE TO STREET EAST 182 STREET No data Street Construction Inspections: Active Department of Transportation No data

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339589541 0215000 2014-02-12 185 MARINE AVE., BROOKLYN, NY, 11209
Inspection Type FollowUp
Scope Complete
Safety/Health Safety
Close Conference 2014-02-12
Case Closed 2014-02-18

Related Activity

Type Inspection
Activity Nr 568219
Safety Yes
339048423 0215000 2013-05-07 89 BLEECKER STREET, NEW YORK, NY, 10012
Inspection Type Referral
Scope Complete
Safety/Health Safety
Close Conference 2013-05-07
Emphasis L: FALL
Case Closed 2015-10-07

Related Activity

Type Referral
Activity Nr 817237
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2013-06-24
Current Penalty 2200.0
Initial Penalty 2200.0
Final Order 2013-07-24
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows: Site: 89 Bleecker Street New York, NY On or about 5/7/13 a) Employees were exposed to fall hazards from approximately 10 feet high while working/walking on a scaffold that was not fully planked.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2013-06-24
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-07-24
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access. Site: 89 Bleecker Street New York, NY On or about 5/7/13 a) Employer did not ensure that the scaffold utilized by the employees was provided with an access ladder.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2013-06-24
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-07-24
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Site: 89 Bleecker Street New York, NY On or about 5/7/13 a) Employees working/walking on a scaffold were exposed to fall from approximately 10 feet high.
Citation ID 01001D
Citaton Type Serious
Standard Cited 19260452 C02
Issuance Date 2013-06-24
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-07-24
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(c)(2): Frames and panels shall be braced by cross, horizontal, or diagonal braces, or combination thereof, which secure vertical members together laterally. The cross braces shall be of such length as will automatically square and align vertical members so that the erected scaffold is always plumb, level, and square. All brace connections shall be secured. Site: 89 Bleecker Street New York, NY On or about 5/7/13 a) The employees were exposed to fall hazards, the scaffold was assembled without the cross braces.
Citation ID 01001E
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2013-06-24
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-07-24
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer shall have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. The training shall include the following areas, as applicable: Site: 89 Bleecker Street New York, NY On or about 5/7/13 a) Employees were not trained to understand and recognized the hazards associated with the work been done.
335682191 0215000 2012-08-09 185 MARINE AVE., BROOKLYN, NY, 11209
Inspection Type Referral
Scope Complete
Safety/Health Safety
Close Conference 2012-08-10
Emphasis L: FALL, P: FALL
Case Closed 2018-03-13

Related Activity

Type Referral
Activity Nr 496331
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2013-01-30
Abatement Due Date 2013-02-11
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2013-11-18
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Cross braces shall not be used as a means of access. a) Sidewalk shed on Marine Ave. side, north of jobsite: An employee was working on a 10-foot-high sidewalk shed, and then climbed down the cross braces of an adjacent supported scaffold to ground. Employee slipped and fell as he was climbing down the cross braces. Cross braces was used as a means of access. On or about 08/09/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT CERTIFICATION OF ABATEMENT FOR THIS ITEM. FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2013-01-30
Abatement Due Date 2013-02-11
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2013-11-18
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers. a) Sidewalk shed on Marine Ave. side, north of jobsite: An employee was working on a 10-foot-high sidewalk shed. The interior side of the sidewalk shed was open and the employee was not protected from falling to ground by the use of fall protection systems. The employee was exposed to falling approximately 10 feet. On or about 08/09/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT CERTIFICATION OF ABATEMENT FOR THIS ITEM. FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2013-01-30
Abatement Due Date 2013-02-19
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2013-11-18
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer shall have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a) Jobsite: The employer did not provide training to an employee who worked from a sidewalk shed. Employee could not recognize hazards associated with scaffolds, and was exposed to hazards, including but not limited to: climbing cross braces of supported scaffold as a means of access, and falling approximately 10 feet from sidewalk shed to ground. On or about 08/09/12. NOTE: IN ADDITION TO CERTIFICATION OF ABATEMENT, THE EMPLOYER IS REQUIRED TO SUBMIT DOCUMENTATION OF ABATEMENT FOR THIS ITEM. FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19.