Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-12-04
|
Emphasis |
L: FALL
|
Case Closed |
2019-03-11
|
Related Activity
Type |
Referral |
Activity Nr |
1406317 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260405 A01 I |
Issuance Date |
2019-01-31 |
Current Penalty |
2842.0 |
Initial Penalty |
2842.0 |
Final Order |
2019-02-28 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(b)(2): All pull boxes, junction boxes, and fittings were not provided with covers: A. On or about 12/04/2018, on the second floor of 142-28 59th Ave. Flushing, NY Live parts in a pull box in the hallway were not covered. B. On or about 12/04/2018, on the second floor of 142-28 59th Ave. flushing, NY Live parts in a outlet box in the living room were not covered. ABATEMENT VERIFICATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19. |
|
|
Inspection Type |
Prog Related
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-10-31
|
Case Closed |
2019-08-27
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260403 I02 I |
Issuance Date |
2018-04-20 |
Abatement Due Date |
2018-04-30 |
Current Penalty |
0.0 |
Initial Penalty |
3696.0 |
Final Order |
2018-05-14 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs Location: 961 Madison St. On or about: 31 October 2017 a) Employees were doing concrete masonry work while being exposed to live parts. A electrical circuit breakerl was missing its cover to guard against accidental contact. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B14 |
Issuance Date |
2018-04-20 |
Abatement Due Date |
2018-04-26 |
Current Penalty |
4750.0 |
Initial Penalty |
5174.0 |
Final Order |
2018-05-14 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(14): Each employee working on, at, above, or near wall openings (including those with chutes attached), where the outside bottom edge of the wall opening was 6 feet (1.8 m) or more above lower levels and the inside bottom edge of the wall opening is less than 39 inches (1.0 M) above the walking/working surface, is not protected from falling by the use of a guardrail system, a safety net system, or a personal fall arrest system. Location: 961 Madison St. On or about: 31 October 2017 a) Employees were doing concrete masonry work while being exposed to fall hazard. employees were laying masonry blocks at a wall opening without using some form of fall protection. |
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-09-03
|
Emphasis |
L: FALL
|
Case Closed |
2015-10-07
|
Related Activity
Type |
Referral |
Activity Nr |
1016555 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260100 A |
Issuance Date |
2015-09-10 |
Current Penalty |
1200.0 |
Initial Penalty |
2000.0 |
Final Order |
2015-09-18 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) On or about September 3, 2015- job site at 50-35 Deepdale Place, Little Neck, NY 11362 the employer permitted an employee to work below a scaffold where over head brick work was being performed without a protective helmet. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260451 B01 II |
Issuance Date |
2015-09-10 |
Abatement Due Date |
2015-09-29 |
Current Penalty |
1680.0 |
Initial Penalty |
2800.0 |
Final Order |
2015-09-18 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(1)(ii): The platform was not planked or decked as fully as possible and the remaining open space between the platform and the uprights exceeded 9.5 inches (24.1 cm): a) On or about September 3, 2015- job site at 50-35 Deepdale Place, Little Neck, NY 11362 the employer permitted employees to work on a tubular welded frame scaffold, approximately 11 feet 9 inches above the next lower level, that was not fully planked. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19260451 B04 |
Issuance Date |
2015-09-10 |
Abatement Due Date |
2015-09-29 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-09-18 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(4): Each end of a platform, unless cleated or otherwise restrained by hooks or equivalent means, shall extend over the centerline of its support at least 6 inches (15 cm): a) On or about September 3, 2015- job site at 50-35 Deepdale Place, Little Neck, NY 11362 the employer permitted employees to work on a tubular welded frame scaffold, approximately 11 feet 9 inches above the next lower level, whose planks did not extend at least 6 inches over its support. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED. |
|
Citation ID |
01002C |
Citaton Type |
Serious |
Standard Cited |
19260451 C02 |
Issuance Date |
2015-09-10 |
Abatement Due Date |
2015-09-29 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-09-18 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: a) On or about September 3, 2015- job site at 50-35 Deepdale Place, Little Neck, NY 11362 the employer permitted employees to work on a tubular welded frame scaffold, approximately 11 feet 9 inches above the next lower level, that did not have base plates or mud sills installed on the support legs. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED. |
|
Citation ID |
01002D |
Citaton Type |
Serious |
Standard Cited |
19260451 F03 |
Issuance Date |
2015-09-10 |
Abatement Due Date |
2015-09-29 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-09-18 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(f)(3): Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: a) On or about September 3, 2015- job site at 50-35 Deepdale Place, Little Neck, NY 11362 the employer permitted employees to work on a tubular welded frame scaffold, approximately 11 feet 9 inches above the next lower level, that was not inspected by a competent person prior to use. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED. |
|
Citation ID |
01002G |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 |
Issuance Date |
2015-09-10 |
Abatement Due Date |
2015-09-29 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-09-18 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level: a) On or about September 3, 2015- job site at 50-35 Deepdale Place, Little Neck, NY 11362 the employer permitted employees to work on a tubular welded frame scaffold, approximately 11 feet 9 inches above the next lower level, without fall protection. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED. |
|
|