Name: | K&J CONSTRUCTION CONSULTANT SERVICE INC |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Inactive |
Date of registration: | 30 Sep 2011 (13 years ago) |
Date of dissolution: | 29 Aug 2019 |
Entity Number: | 4148286 |
ZIP code: | 11740 |
County: | New York |
Place of Formation: | New York |
Address: | 144 BROADWAY, GREEN LAWN, NY, United States, 11740 |
Principal Address: | 144 BROADWAY, GREENLAWN, NY, United States, 11740 |
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Name | Role | Address |
---|---|---|
THE CORPORATION | DOS Process Agent | 144 BROADWAY, GREEN LAWN, NY, United States, 11740 |
Name | Role | Address |
---|---|---|
jenny chiang | Agent | 144 broadway, GREENLAWN, NY, 11740 |
Name | Role | Address |
---|---|---|
JENNY CHIANG | Chief Executive Officer | 144 BROADWAY, GREENLAWN, NY, United States, 11740 |
Start date | End date | Type | Value |
---|---|---|---|
2021-11-01 | 2022-04-02 | Shares | Share type: NO PAR VALUE, Number of shares: 200, Par value: 0 |
2013-10-21 | 2021-11-02 | Address | 144 BROADWAY, GREENLAWN, NY, 11740, USA (Type of address: Chief Executive Officer) |
2011-09-30 | 2021-11-01 | Shares | Share type: NO PAR VALUE, Number of shares: 200, Par value: 0 |
2011-09-30 | 2021-11-02 | Address | C/O NYCORPORATION.COM, 1971 WESTERN AVE #1121, ALBANY, NY, 12203, USA (Type of address: Registered Agent) |
2011-09-30 | 2021-11-02 | Address | 144 BROADWAY, GREEN LAWN, NY, 11740, USA (Type of address: Service of Process) |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
211102000893 | 2021-11-01 | CERTIFICATE OF CHANGE BY ENTITY | 2021-11-01 |
190829000202 | 2019-08-29 | CERTIFICATE OF DISSOLUTION | 2019-08-29 |
131021002060 | 2013-10-21 | BIENNIAL STATEMENT | 2013-09-01 |
110930000097 | 2011-09-30 | CERTIFICATE OF INCORPORATION | 2011-09-30 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
339126310 | 0215600 | 2013-06-18 | 119-15 83 AVE, KEW GARDENS, NY, 11415 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 824681 |
Safety | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260020 B01 |
Issuance Date | 2013-11-22 |
Abatement Due Date | 2014-01-13 |
Current Penalty | 1000.0 |
Initial Penalty | 2000.0 |
Contest Date | 2013-12-10 |
Final Order | 2014-04-09 |
Nr Instances | 2 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.20(b)(1): The employer did not initiate and maintain an accident prevention program as may be necessary to comply with the General safety and health provisions covered in 29 CFR 1926.20: a) On or about June 17, 2013-Job site at 119-15 83 Avenue Kew Gardens, NY 11415 The employer did not have any person or system in place to identify hazards. WRITTEN ABATEMENT DOCUMENTATION IS REQUIRED PURSUANT TO 29 CFR 1903.19. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19260021 B02 |
Issuance Date | 2013-11-22 |
Abatement Due Date | 2014-01-13 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Contest Date | 2013-12-10 |
Final Order | 2014-04-09 |
Nr Instances | 2 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: a) On or about June 17, 2013-Job site at 119-15 83 Avenue Kew Gardens, NY 11415 Employees were not able to identify excavation hazards or unsafe use of a Hydraulic Caterpillar Excavator Model 314. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260651 C02 |
Issuance Date | 2013-11-22 |
Abatement Due Date | 2014-01-13 |
Current Penalty | 1000.0 |
Initial Penalty | 2000.0 |
Contest Date | 2013-12-10 |
Final Order | 2014-04-09 |
Nr Instances | 15 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.651(c)(2): A means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress was not located in trench excavations more than 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees: a) On or about June 17, 2013-Job site at 119-15 83 Avenue Kew Gardens, NY 11415 Employee exiting and entering a 16-foot deep excavation to unhook a chain from an I-beam had no safe means of access or egress. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19. |
Citation ID | 01003A |
Citaton Type | Serious |
Standard Cited | 19260651 H01 |
Issuance Date | 2013-11-22 |
Abatement Due Date | 2014-01-13 |
Current Penalty | 1400.0 |
Initial Penalty | 2800.0 |
Contest Date | 2013-12-10 |
Final Order | 2014-04-09 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.651(h)(1): Employees were working in excavations in which there was accumulated water, or excavations in which water was accumulating, and adequate precautions had not been taken to protect employees against the hazards posed by water accumulation: a) On or about June 17, 2013-Job site at 119-15 83 Avenue Kew Gardens, NY 11415 Employee expose to rain while in in a 16-foot excavation which destabilized an un-shored wall and caused a collapse. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19. |
Citation ID | 01003B |
Citaton Type | Serious |
Standard Cited | 19260651 J02 |
Issuance Date | 2013-11-22 |
Abatement Due Date | 2014-01-13 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Contest Date | 2013-12-10 |
Final Order | 2014-04-09 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.651(j)(2): Employees were not protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations: a) On or about June 17, 2013-Job site at 119-15 83 Avenue Kew Gardens, NY 11415 Employee trapped up to his chest by section of spoils falling into the 16-foot excavation. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19. |
Citation ID | 01004 |
Citaton Type | Serious |
Standard Cited | 19260652 A01 |
Issuance Date | 2013-11-22 |
Abatement Due Date | 2014-01-13 |
Current Penalty | 1400.0 |
Initial Penalty | 2800.0 |
Contest Date | 2013-12-10 |
Final Order | 2014-04-09 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(b) or (c): a) On or about June 17, 2013-Job site at 119-15 83 Avenue Kew Gardens, NY 11415 Employer allowed employee to work in un-shored excavations up to a depth of 16-feet building a retaining walls. WRITTEN ABATEMENT DOCUMENTATION IS REQUIRED PURSUANT TO 29 CFR 1903.19. |