342554235
|
0215600
|
2017-08-17
|
75-76 180TH STREET, FRESH MEADOWS, NY, 11366
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2017-08-17
|
Case Closed |
2017-11-03
|
Related Activity
Type |
Inspection |
Activity Nr |
1192468 |
Health |
Yes |
|
|
341924454
|
0215600
|
2017-08-16
|
75-76 180TH STREET, FRESH MEADOWS, NY, 11366
|
|
Inspection Type |
Prog Related
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2017-08-16
|
|
342552510
|
0215600
|
2017-08-16
|
75-76 180TH STREET, FRESH MEADOWS, NY, 11366
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-08-16
|
Case Closed |
2017-08-16
|
Related Activity
Type |
Inspection |
Activity Nr |
1192383 |
Safety |
Yes |
|
|
341923837
|
0215600
|
2016-11-21
|
75-76 180TH STREET, FRESH MEADOWS, NY, 11366
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-11-21
|
Case Closed |
2022-09-13
|
Related Activity
Type |
Complaint |
Activity Nr |
1157520 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1192468 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260095 A |
Issuance Date |
2017-04-05 |
Abatement Due Date |
2017-04-17 |
Current Penalty |
2716.0 |
Initial Penalty |
2716.0 |
Final Order |
2017-05-01 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact. a) On or about November 21, 2016- job site of 75-76 180th Street, Fresh Meadows, NY 11366 an employee was using a Makita GA 7021 grinder, to cut concrete blocks, while not wearing eye protection. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PERSUANT TO 29 CFR 1903.19 b) On or about November 21, 2016- job site of 75-76 180th Street, Fresh Meadows, NY 11366 employees were mixing and applying Type I-II Portland Cement, a corrosive, while not wearing eye protection. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PERSUANT TO 29 CFR 1903.19 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260300 B01 |
Issuance Date |
2017-04-05 |
Abatement Due Date |
2017-04-17 |
Current Penalty |
2716.0 |
Initial Penalty |
2716.0 |
Final Order |
2017-05-01 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: On or about November 21, 2016- job site of 75-76 180th Street, Fresh Meadows, NY 11366 an employee was using a Makita GA 7021 grinder, to cut concrete blocks, that had its blade guard removed. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PERSUANT TO 29 CFR 1903.19 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260701 B |
Issuance Date |
2017-04-05 |
Abatement Due Date |
2017-04-17 |
Current Penalty |
2716.0 |
Initial Penalty |
2716.0 |
Final Order |
2017-05-01 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall or come against, was not guarded to eliminate the hazard of impalement: On or about November 21, 2016- job site of 75-76 180th Street, Fresh Meadows, NY 11366 employees walking down a narrow pathway, must walk by uncapped rebar to get to their work area. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PERSUANT TO 29 CFR 1903.19 |
|
|
341924686
|
0215600
|
2016-11-21
|
75-76 180TH STREET, FRESH MEADOWS, NY, 11366
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2016-11-21
|
Case Closed |
2022-08-01
|
Related Activity
Type |
Complaint |
Activity Nr |
1157520 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1192383 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19101200 E01 |
Issuance Date |
2017-04-05 |
Abatement Due Date |
2017-05-22 |
Current Penalty |
1630.0 |
Initial Penalty |
1630.0 |
Final Order |
2017-05-01 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program which at included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): (Construction Reference: 1926.59) (a) On or about November 21, 2016, at work site at 75-76 180th Street, Fresh Meadows, NY 11366 Employer did not have a written hazard communication program despite requiring three employees to use corrosive cement products such as Quik-Rete Concrete Mix No. 1101 and Quik-Rete Fast-Setting Concrete Mix No. 1004 to construct block walls. WRITTEN ABATEMENT CERTIFICATION REQUIRED PURSUANT TO 29 CFR 1903.19. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19101200 G08 |
Issuance Date |
2017-04-05 |
Abatement Due Date |
2017-05-22 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-05-01 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(g)(8): The employer did not maintain copies of the required material safety data sheets for each hazardous chemical in the workplace: (Construction Reference: 1926.59) (a) On or about November 21, 2016, at work site at 75-76 180th Street, Fresh Meadows, NY 11366 Employer did not maintain or provide copies of safety data sheets to employees despite requiring three employees to use corrosive cement products such as Quik-Rete Concrete Mix No. 1101 and Quik-Rete Fast-Setting Concrete Mix No. 1004 to construct block walls. WRITTEN ABATEMENT CERTIFICATION REQUIRED PURSUANT TO 29 CFR 1903.19. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19101200 H01 |
Issuance Date |
2017-04-05 |
Abatement Due Date |
2017-05-22 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-05-01 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (Construction Reference: 1926.59) (a) On or about November 21, 2016, at work site at 75-76 180th Street, Fresh Meadows, NY 11366 Employer did not provide hazard communication training to three employees who were using corrosive cement products such as Quik-Rete Concrete Mix No. 1101 and Quik-Rete Fast-Setting Concrete Mix No. 1004 to construct block walls. WRITTEN ABATEMENT CERTIFICATION REQUIRED PURSUANT TO 29 CFR 1903.19. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260025 A |
Issuance Date |
2017-04-05 |
Abatement Due Date |
2017-04-17 |
Current Penalty |
1630.0 |
Initial Penalty |
1630.0 |
Final Order |
2017-05-01 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.25(a): During the course of construction, alteration, or repairs, debris was not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures: (a) On or about November 21, 2016, at work site at 75-76 180th Street, Fresh Meadows, NY 11366 Employer did not ensure that the work area and passageways around the building under alteration was cleared of demolished materials such as wall-board, tar paper, scraps of lumber, some with protruding nails, and garbage. WRITTEN ABATEMENT CERTIFICATION REQUIRED PURSUANT TO 29 CFR 1903.19. |
|
|