Search icon

ADCO BUILDERS CORP.

Company Details

Name: ADCO BUILDERS CORP.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 26 Oct 2011 (13 years ago)
Entity Number: 4157843
ZIP code: 11735
County: Kings
Place of Formation: New York
Address: 38 11th Ave, SOUTH FARMINGDALE, NY, United States, 11735
Principal Address: 854 HUMBOLDT ST, BROOKLYN, NY, United States, 11222

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 38 11th Ave, SOUTH FARMINGDALE, NY, United States, 11735

Chief Executive Officer

Name Role Address
ADAM KAHATI Chief Executive Officer 854 HUMBOLDT ST, BROOKLYN, NY, United States, 11222

History

Start date End date Type Value
2023-10-02 2023-10-02 Address 854 HUMBOLDT ST, BROOKLYN, NY, 11222, USA (Type of address: Chief Executive Officer)
2023-06-04 2023-10-02 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2023-06-04 2023-06-04 Address 854 HUMBOLDT ST, BROOKLYN, NY, 11222, USA (Type of address: Chief Executive Officer)
2023-06-04 2023-10-02 Address 854 HUMBOLDT ST, BROOKLYN, NY, 11222, USA (Type of address: Chief Executive Officer)
2023-06-04 2023-10-02 Address 38 11th Ave, SOUTH FARMINGDALE, NY, 11735, USA (Type of address: Service of Process)
2013-10-31 2023-06-04 Address 854 HUMBOLDT ST, BROOKLYN, NY, 11222, USA (Type of address: Chief Executive Officer)
2011-10-26 2023-06-04 Address 854 HUMBOLDT STREET, BROOKLYN, NY, 11222, USA (Type of address: Service of Process)
2011-10-26 2023-06-04 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0

Filings

Filing Number Date Filed Type Effective Date
231002001956 2023-10-02 BIENNIAL STATEMENT 2023-10-01
230604000436 2023-06-04 BIENNIAL STATEMENT 2021-10-01
131031002414 2013-10-31 BIENNIAL STATEMENT 2013-10-01
111026000248 2011-10-26 CERTIFICATE OF INCORPORATION 2011-10-26

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341366664 0215000 2016-03-31 69 JAVA STREET, BROOKLYN, NY, 11222
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2016-03-31
Emphasis L: FALL, L: GUTREH
Case Closed 2018-06-04

Related Activity

Type Referral
Activity Nr 1077422
Safety Yes
Type Inspection
Activity Nr 1136670
Safety Yes

Violation Items

Citation ID 01003
Citaton Type Serious
Standard Cited 19260405 A02 II E
Issuance Date 2016-08-01
Abatement Due Date 2016-08-11
Current Penalty 900.0
Initial Penalty 1600.0
Final Order 2016-08-22
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(a)(2)(ii)(E): Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage Location: 69 Java, Street Brooklyn NY 1st floor On or about: March 31st 2016 a) Lamps used for general illumination in the basement were not protected with a cage or cover.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260701 B
Issuance Date 2016-08-01
Abatement Due Date 2016-08-11
Current Penalty 1800.0
Initial Penalty 2800.0
Final Order 2016-08-22
Nr Instances 1
Nr Exposed 4
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall or come against, was not guarded to eliminate the hazard of impalement: Location: 69 Java Street Brooklyn NY 1st floor On or about: March 31st 2016 a) Employees working and walking near and around exposed unprotected rebar.
Citation ID 01005
Citaton Type Serious
Standard Cited 19261052 B01
Issuance Date 2016-08-01
Abatement Due Date 2016-08-11
Current Penalty 1000.0
Initial Penalty 2000.0
Final Order 2016-08-22
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(b)(1): Foot traffic was not prohibited on stairways where the treads and/or landings of pan stairs were to be filled in with concrete or other material at a later date and stairs were not temporarily fitted with wood or other solid material at least to the top edge of each pan. Location: 69 Java Street Brooklyn NY staircase from the 1st floor to the basement. On or about: March 31st 2016 a) Each Stairway and landing from the first floor to the basement were not temporarily filled with wood or other solid material. Stairway used to access work area.
Citation ID 01006
Citaton Type Serious
Standard Cited 19261053 A24
Issuance Date 2016-08-01
Abatement Due Date 2016-08-11
Current Penalty 1400.0
Initial Penalty 2800.0
Final Order 2016-08-22
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(a)(24): The side rails of through or sidestep fixed ladders did not extend 42 inches (1.1 m) above the top of the access level or landing platform served by the ladder: Location: 69 Java Street Brooklyn NY 1st floor On or about: March 31st 2016 a) Employees used 10 foot ladder to access work area and the ladder did not extend 3 feet above the landing.
Citation ID 01007A
Citaton Type Serious
Standard Cited 19260403 I02 I
Issuance Date 2016-08-01
Abatement Due Date 2016-08-11
Current Penalty 1900.0
Initial Penalty 2000.0
Final Order 2016-08-22
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph. Location: 69 Java Street, Brooklyn, NY 1st floor On or about: March 31st 2016 a) Energized circuit breaker panel was not closed with a cover. Employees walked and worked in and around the area of the energized panel.
Citation ID 01007B
Citaton Type Serious
Standard Cited 19260404 B01
Issuance Date 2016-08-01
Abatement Due Date 2016-08-11
Current Penalty 0.0
Initial Penalty 2800.0
Final Order 2016-08-22
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(b)(1): The employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors. Location: 69 Java Street Brooklyn NY 1st floor On or about: March 31st 2016 a) Employees were utilizing power tools and the cords were not provided with GFCI's.

Date of last update: 26 Mar 2025

Sources: New York Secretary of State