Name: | EDMONT CARPENTRY & PAINTING INC. |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Active |
Date of registration: | 07 Nov 2011 (13 years ago) |
Entity Number: | 4162408 |
ZIP code: | 10520 |
County: | Westchester |
Place of Formation: | New York |
Address: | 71 NORTH RIVERSIDE AVENUE, APT. 1, CROTON ON HUDSON, NY, United States, 10520 |
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Name | Role | Address |
---|---|---|
THE CORPORATION | DOS Process Agent | 71 NORTH RIVERSIDE AVENUE, APT. 1, CROTON ON HUDSON, NY, United States, 10520 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
111107000068 | 2011-11-07 | CERTIFICATE OF INCORPORATION | 2011-11-07 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
346775018 | 0216000 | 2023-06-15 | 19 POCANTICO RD, OSSINING, NY, 10562 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 2042503 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Other |
Standard Cited | 19260404 F06 |
Issuance Date | 2023-08-11 |
Current Penalty | 1000.0 |
Initial Penalty | 2846.0 |
Final Order | 2023-09-05 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Imminent Danger |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: On or about: June 15th, 2023 Location: 19 Pocantico Rd, Ossining, NY 10562 a) Employees used a portable GFCI plug with missing ground prong to power up tools. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260451 G01 I |
Issuance Date | 2023-08-11 |
Current Penalty | 3166.0 |
Initial Penalty | 4688.0 |
Final Order | 2023-09-05 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Imminent Danger |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: On or about: June 15th, 2023 Location: 19 Pocantico Rd, Ossining, NY 10562 a) Employee working on an elevated platform of a ladder jack scaffold more than 20 ft above the ground level without personal fall protection system. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260452 K01 |
Issuance Date | 2023-08-11 |
Current Penalty | 3166.0 |
Initial Penalty | 4688.0 |
Final Order | 2023-09-05 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Imminent Danger |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.452(k)(1): Platforms exceeded a height of 20 feet (6.1 m) On or about: June 15th, 2023 Location: 19 Pocantico Rd, Ossining, NY 10562 a) Employee working on an elevated platform of a ladder jack scaffold 20.7 ft above the ground. |
Citation ID | 01004 |
Citaton Type | Serious |
Standard Cited | 19260452 K03 |
Issuance Date | 2023-08-11 |
Current Penalty | 3168.0 |
Initial Penalty | 4688.0 |
Final Order | 2023-09-05 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Imminent Danger |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.452(k)(3): The ladder jack shall be so designed and constructed that it will bear on the side rails and ladder rungs or on the ladder rungs alone. If bearing on rungs only, the bearing area shall include a length of at least 10 inches (25.4 cm) on each rung. On or about: June 15th, 2023 Location: 19 Pocantico Rd, Ossining, NY 10562 a) Employee was standing of a wood plank set on the ladder stabilizer as part of the ladder jack scaffold. |
Loan Number | Loan Funded Date | SBA Origination Office Code | Loan Delivery Method | Borrower Street Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
5322318507 | 2021-02-27 | 0202 | PPP | 71 N Riverside Ave Apt 1, Croton on Hudson, NY, 10520-1929 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
USDOT Number | Carrier Operation | MCS-150 Form Date | MCS-150 Mileage | MCS-150 Year | Power Units | Drivers | Operation Classification | |||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
3441110 | Intrastate Non-Hazmat | 2020-06-16 | - | - | 2 | 1 | Private(Property) | |||||||||||||||||||||||||||||||||||||||||||||||||||
|
Total Number of Inspections for the measurement period (24 months) | 0 |
Driver Fitness BASIC Serious Violation Indicator | No |
Vehicle Maintenance BASIC Acute/Critical Indicator | No |
Unsafe Driving BASIC Acute/Critical Indicator | No |
Driver Fitness BASIC Roadside Performance measure value | 0 |
Hours-of-Service (HOS) Compliance BASIC Roadside Performance measure value | 0 |
Total Number of Driver Inspections for the measurment period | 0 |
Vehicle Maintenance BASIC Roadside Performance measure value | 0 |
Total Number of Vehicle Inspections for the measurement period | 0 |
Controlled Substances and Alcohol BASIC Roadside Performance measure value | 0 |
Unsafe Driving BASIC Roadside Performance Measure Value | 0 |
Number of inspections with at least one Driver Fitness BASIC violation | 0 |
Number of inspections with at least one Hours-of-Service BASIC violation | 0 |
Total Number of Driver Inspections containing at least one Driver Out-of-Service Violation | 0 |
Number of inspections with at least one Vehicle Maintenance BASIC violation | 0 |
Total Number of Vehicle Inspections containing at least one Vehicle Out-of-Service violation | 0 |
Number of inspections with at least one Controlled Substances and Alcohol BASIC violation | 0 |
Number of inspections with at least one Unsafe Driving BASIC violation | 0 |
Date of last update: 26 Mar 2025
Sources: New York Secretary of State