OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340723816 0215000 2015-06-17 155 WEST 126 STREET, NEW YORK, NY, 10040
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2015-06-17
Case Closed 2015-07-06

Related Activity

Type Inspection
Activity Nr 1005239
Safety Yes
340707959 0215000 2015-06-10 2216 AVENUE L, BROOKLYN, NY, 11210
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2015-06-10
Case Closed 2015-06-18

Related Activity

Type Inspection
Activity Nr 960535
Safety Yes
340052398 0215000 2014-10-30 155 WEST 126TH STREET, NEW YORK, NY, 10040
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2014-10-30
Emphasis L: FALL
Case Closed 2018-02-05

Related Activity

Type Complaint
Activity Nr 918627
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B02 II
Issuance Date 2014-12-01
Current Penalty 3080.0
Initial Penalty 3080.0
Final Order 2014-12-26
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(2)(ii): Each employee on a walking/working surface 6 feet (1.8 m) or more above a lower level where leading edges are under construction, but who was not engaged in the leading edge work, was not protected from falling by a guardrail system, safety net system, or personal fall arrest system. On or about October 30, 2014 Location; Ground floor, entry/exit 155 West 126th Street, New York, NY 10040 A). Employees were exposed to fall hazards in excess of 10 feet to the lower level because they were not protected from falling by means of Personal Fall Arrest System, Guardrails, Safety Nets or Controlled access zone. The floor at the entry/exit was removed exposing the floor joists and basement below. Employees were utilizing this area as a means of entry/exit into the project.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19261052 C04
Issuance Date 2014-12-01
Abatement Due Date 2014-12-11
Current Penalty 2640.0
Initial Penalty 2640.0
Final Order 2014-12-26
Nr Instances 3
Nr Exposed 2
Related Event Code (REC) Imminent Danger
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(4): Employer did not ensure Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structural members were provided between the top rail of the stair rail system and the stairway steps: On or about October 30, 2014, and again on October 31, 2014. Location; 155 West 126th Street, New York, NY West structure fourth floor stairway. a). Employees utilizing stairs to traverse through the project from ground level to the roof, were not protected from falls off the stairs because the stairwells were not protected with midrails, screens, mesh, or intermediate vertical members.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19261052 B01
Issuance Date 2014-12-01
Abatement Due Date 2014-12-11
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-12-26
Nr Instances 24
Nr Exposed 2
Related Event Code (REC) Imminent Danger
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(b)(1): Foot traffic was not prohibited on stairways where the treads and/or landings of pan stairs were to be filled in with concrete or other material at a later date and stairs were not temporarily fitted with wood or other solid material at least to the top edge of each pan.Temporary treads and landings used for pan stairs that were to be filled in with concrete or other solid material at a later date were worn below the level of the top edge of the pan. On or about October 30, 2014 and October 31, 2014 Location: 155 West 126th Street, New York, NY every stair well throughout the project. Employees were traversing throughout the project using stairwells and were exposed to trip and fall hazards because the stair landing pans were not filled in with a solid material and the material used to fill stair treads had been worn down below the top lip of the tread pan.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19261052 C12
Issuance Date 2014-12-01
Abatement Due Date 2014-12-11
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-12-26
Nr Instances 4
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(12): Unprotected sides and edges of stairway landings were not provided with guardrail systems that meet the criteria contained in Subpart M of 29 CFR 1926: On or about October 30, 2014, and again on October 31, 2014. Location 155 West 126th Street, New York, NY 10040 a). Employees were utilizing stairways to traverse throughout the project and were exposed to fall hazards because the Landings were not equipped with handrails.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19261052 C01
Issuance Date 2014-12-01
Abatement Due Date 2014-12-11
Current Penalty 6160.0
Initial Penalty 6160.0
Final Order 2014-12-26
Nr Instances 3
Nr Exposed 2
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a handrail system along each unprotected side or edge: On or about October 30, 2014, and again on October 31, 2014. Location: 155 West 126th Street, New York, NY a). Employees working on site traversed the west stairs from roof top to street level numerous times daily to complete their work. Employees were exposed to fall hazards because the stair systems was not equipped with a handrail system along each unprotected side or edge of the stairs Adar Steel , Inc was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.1052 (c)(1)(ii) Stairways, which was contained in OSHA inspection number 960535, citation number 1, item number 3 and was affirmed as a final order on 10/24/2014, with respect to a workplace located at 2216 Avenue L. Brooklyn, NY 11210.
339620312 0215000 2014-03-06 105 METROPOLITAN AVE, BROOKLYN, NY, 11249
Inspection Type Fat/Cat
Scope Complete
Safety/Health Safety
Close Conference 2014-03-06
Emphasis L: FALL, N: SVEP
Case Closed 2018-08-28

Related Activity

Type Inspection
Activity Nr 962149
Safety Yes
Type Accident
Activity Nr 875536

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260760 A01
Issuance Date 2014-09-02
Current Penalty 7000.0
Initial Penalty 7000.0
Final Order 2014-09-25
Nr Instances 1
Nr Exposed 5
Related Event Code (REC) Accident
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems. a) Employees engaged in q-decking installations were not protected from fall hazards while working at unprotected sides or/and edges at the site and the area was not identified as a controlled decking zone. An employee (the deceased) did not have a harness and other employees were not tied-off when working/walking near the sides/edges. Employees were exposed to potential fall hazard of approximately 24 ft. to ground below; on or about 3/6/14.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260451 B01 I
Issuance Date 2014-09-02
Current Penalty 15400.0
Initial Penalty 15400.0
Final Order 2014-09-25
Nr Instances 1
Nr Exposed 5
Related Event Code (REC) Accident
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary. Location: 105 Metropolitan Ave., Brooklyn, NY. a) Employer did not ensure that a tubular welded scaffold utilized by employees as means of access and/or to pass q-decking material to the structural steel erection area was fully planked. The top work platform of the three tier scaffold was not fully planked; on or about 3/6/14. Adar Steel was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.451(b)(1)(i), which was contained in OSHA inspection number 910524, citation number 01, item number 003 and was affirmed as a final order on 11/4/2013, with respect to a workplace located at 2216 Ave L, Brooklyn, N.Y.
Citation ID 02002
Citaton Type Repeat
Standard Cited 19260451 E01
Issuance Date 2014-09-02
Current Penalty 15400.0
Initial Penalty 15400.0
Final Order 2014-09-25
Nr Instances 1
Nr Exposed 5
Related Event Code (REC) Accident
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Cross-braces were used as a means of access. Location: 105 Metropolitan Ave., Brooklyn, NY. a) Employer did not ensure that a 3 tier tubular welded scaffold utilized by employees as means of access to the structural steel erection area was equipped with means to access the area safely. Employees were exposed to fall hazards of up to approximately 24 ft. while climbing the scaffold's cross-braces to access the scaffold's platforms; on or about 3/6/14. Adar Steel was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.451(e)(1) which was contained in OSHA inspection number 781121 citation number 01, item number002 and was affirmed as a final order on 3/5/2013, with respect to a workplace located at 29-20 Healy Ave, Far Rockaway, N.Y.
Citation ID 02003
Citaton Type Repeat
Standard Cited 19260451 G01 VII
Issuance Date 2014-09-02
Current Penalty 15400.0
Initial Penalty 15400.0
Final Order 2014-09-25
Nr Instances 1
Nr Exposed 5
Related Event Code (REC) Accident
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. Location: 105 Metropolitan Ave., Brooklyn, NY. a) An employee was not wearing a fall arrest system or protected by a guardrail system when he fell from the scaffold's work platform 19ft to his death. The deceased was using the scaffold to pass q-decking material to the structural steel erection area and to gain access to that area; on or about 3/6/14. Adar Steel was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.451(g)(1)(vii) which was contained in OSHA inspection number 910524, citation number 01, item number 004 and was affirmed as a final order on 11/4/2013, with respect to a workplace located at 2216 Ave L, Brooklyn, N.Y.
339605354 0215000 2014-02-25 2216 AVENUE L, BROOKLYN, NY, 11210
Inspection Type FollowUp
Scope Complete
Safety/Health Safety
Close Conference 2014-02-25
Emphasis P: FALL, L: FALL
Case Closed 2018-08-28

Related Activity

Type Inspection
Activity Nr 910524
Safety Yes
Type Inspection
Activity Nr 960540
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260403 I02 I
Issuance Date 2014-08-11
Abatement Due Date 2014-08-21
Current Penalty 2200.0
Initial Penalty 2200.0
Final Order 2014-10-24
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph. a) 2nd floor center: Employees used an energized electric panel without cover to operate power supply on the floor. Live parts of the electric panel and circuit breakers were not guarded against accidental contact by employees. On or about 02/25/14. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT CERTIFICATION OF ABATEMENT FOR THIS ITEM. FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260405 G02 III
Issuance Date 2014-08-11
Abatement Due Date 2014-08-21
Current Penalty 2200.0
Initial Penalty 2200.0
Final Order 2014-10-24
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(g)(2)(iii): Flexible cords were not used in continuous lengths without splice or tap. a) 2nd floor, north side room: Employees used an electric powered hand drill to do carpentry work. The hand drills power cord was not used in continuous length and was spliced. On or about 02/25/14. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT CERTIFICATION OF ABATEMENT FOR THIS ITEM. FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261052 C01 II
Issuance Date 2014-08-11
Abatement Due Date 2014-08-21
Current Penalty 2200.0
Initial Penalty 2200.0
Final Order 2014-10-24
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge. a) Stairway between 1st floor and 2nd floor: Employees used a stairway to travel between 1st and 2nd floor. The stairway rise to about 10 feet height and was not equipped with a stairrail system along its unprotected side. On or about 02/25/14. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT CERTIFICATION OF ABATEMENT FOR THIS ITEM. FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19.
Citation ID 01004
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2014-08-11
Current Penalty 2200.0
Initial Penalty 2200.0
Final Order 2014-10-24
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purposes for which they were designed. a) East side of jobsite, side entrance to 1st floor of house: Employees folded and leaned a 5-foot A-frame stepladder on an elevated entrance to access the 1st floor. On or about 02/25/14. Note: Because abatement of this violation is already documented in the inspection case file, the employer need not submit certification of abatement for this violation as normally required by 29 CFR 1903.19.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260404 F06
Issuance Date 2014-08-11
Abatement Due Date 2014-08-19
Current Penalty 4400.0
Initial Penalty 4400.0
Final Order 2014-10-24
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous. a) 2nd floor, north side room: Employees used electric powered tools to do carpentry work. The tools were connected to an extension cord, which was routed to a nearby electric outlet in the same room. The extension cord was missing a ground pin. On or about 02/25/14. 1st REPEAT Adar Steel Inc. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD, ITS EQUIVALENT, OR ESSENTIALLY SIMILAR STANDARD, 29 CFR 1926.404(f)(6), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 910524, CITATION NUMBER 1, ITEM NUMBER 2, ISSUED ON 09/20/2013 WITH A FINAL ORDER DATE OF 10/14/2013.
339157554 0215600 2013-06-28 29-20 HEALY AVE, FAR ROCKAWAY, NY, 11692
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2013-06-28
Case Closed 2013-07-17

Related Activity

Type Inspection
Activity Nr 781121
Safety Yes
339105249 0215000 2013-06-06 2216 AVENUE L, BROOKLYN, NY, 11210
Inspection Type Referral
Scope Complete
Safety/Health Safety
Close Conference 2013-06-06
Emphasis L: FALL
Case Closed 2018-08-28

Related Activity

Type Referral
Activity Nr 822422
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260404 B01 I
Issuance Date 2013-09-20
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2013-10-17
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. Location: 2216 Avenue L Brooklyn NY. On or About: 06/06/13 a) The Circular Saw being used by the employees was not provided with a GFCI protection or an assured equipment grounding program.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260404 F06
Issuance Date 2013-09-20
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2013-10-17
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous. Location: 2216 Avenue L Brooklyn NY. On or About: 06/06/13 a)The orange 25 feet extension cord use to energize the Circular Saw was missing the ground pin.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 B01 I
Issuance Date 2013-09-20
Current Penalty 2400.0
Initial Penalty 2400.0
Final Order 2013-10-17
Nr Instances 2
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary. Location: 2216 Avenue L Brooklyn NY. On or About: 06/06/13 a) Two employees were framing a roof from tubular welded frame scaffolds that were not fully planked.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2013-09-20
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2013-10-17
Nr Instances 2
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. Location: 2216 Avenue Brooklyn, NY. On or about: 06/06/13 a) Two employees were installing ceiling joist from a tubular welded frame scaffold that was not provided with any fall protection system. The employees were exposed to a potential fall hazard of up to 20 feet to the ground below. b) Employees were working from an approximately 20 feet high scaffold platform that was not provided with fall protection.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2013-09-20
Abatement Due Date 2013-10-09
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2013-10-17
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. Location: 2216 Avenue L Brooklyn NY. On or About: 06/06/13 a) Employees were not trained on scaffolds hazards. Two employees were working by the edge of a woking platform without any fall protection while exposed to a potential fall of approximately 20 feet to ground below.
Citation ID 01006
Citaton Type Serious
Standard Cited 19260501 B04 I
Issuance Date 2013-09-20
Current Penalty 2400.0
Initial Penalty 2400.0
Final Order 2013-10-17
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces shall be protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes. Location: 2216 Avenue Brooklyn, NY. On or about: 06/06/13 a) Employees walked and worked near the a floor hole located at the front entrance of the house.
337811210 0215600 2012-12-07 29-20 HEALY AVE, FAR ROCKAWAY, NY, 11692
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2012-12-07
Emphasis L: FALL, P: FALL, L: SANDY
Case Closed 2018-03-09

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2013-02-07
Abatement Due Date 2013-02-15
Current Penalty 1200.0
Initial Penalty 1200.0
Final Order 2013-04-05
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: A). On or about 12/07/12, at the site of 29-20 Healy Ave. Far Rockaway, NY Employees working at the site were in danger of head injury from falling objects such as, but not limited to tools and roof materials from the roof. Protective helmets were not provided. ABATEMENT VERIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2013-02-07
Abatement Due Date 2013-02-15
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2013-04-05
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used: A). On or about 12/07/12, scaffolds at 29-20 Healy Ave. Far Rockaway, NY Employees were ascending/descending a scaffold by climbing the frame and were in danger of falling approximately 24 ft to the ground. An access ladder or equivalent safe devices were not provided. ABATEMENT VERIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B10
Issuance Date 2013-02-07
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2013-04-05
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels and 50-feet (15.25 m) wide or less, was not protected from falling by guardrail systems, safety nets: a) On or about 12/07/12, at the site of 29-20 Healy Ave. Far Rockaway, NY Employees installing new roof on a pitch roof with a slope of 4 in 12 ratios were exposed to the hazard of falling approximately 25 ft to the ground below. ABATEMENT VERIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19.

Date of last update: 26 Mar 2025

Sources: New York Secretary of State