Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260021 B02 |
Issuance Date |
2013-03-08 |
Abatement Due Date |
2013-04-12 |
Current Penalty |
2800.0 |
Initial Penalty |
2800.0 |
Final Order |
2013-04-02 |
Nr Instances |
3 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: a) Entire worksite, on or about 2-19-13: Three employees were performing various construction tasks without the training necessary to recognize the hazards associated with their work. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260304 F |
Issuance Date |
2013-03-08 |
Abatement Due Date |
2013-03-23 |
Current Penalty |
2800.0 |
Initial Penalty |
2800.0 |
Final Order |
2013-04-02 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.304(f): Section 4.1.9(d)(2) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Radial saw(s) were not installed in a manner so as to cause cutting head to return gently to the starting position when released by the operator: a) West side of building, back, on or about 2-19-13: Employees were cutting siding using a radial arm saw that was not equipped with an automatic return that gently returns the saw to its original position when released by the operator. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19260304 G01 |
Issuance Date |
2013-03-08 |
Abatement Due Date |
2013-03-23 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-04-02 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.304(g)(1): The sides of the lower blade were not guarded to the full diameter of the blade by a device that would automatically adjust itself to the thickness of the stock and remain in contact with stock being cut to give maximum protection: a) West side of building, back, on or about 2-19-13: Employees were cutting siding using a radial arm saw that was not equipped with ring guards automatically adjust to enclose the saw blade. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19260404 B01 II |
Issuance Date |
2013-03-08 |
Abatement Due Date |
2013-03-23 |
Current Penalty |
2800.0 |
Initial Penalty |
2800.0 |
Final Order |
2013-04-02 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection: a) North and west side of building, on or about 2-19-13: Employees were operating various power tools that were powered through a receptacle that was not protected by a ground fault circuit interrupter (GFCI). |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19260404 F06 |
Issuance Date |
2013-03-08 |
Abatement Due Date |
2013-03-23 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-04-02 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) North and west side of building, on or about 2-19-13: Employees were operating various power tools and a compressor that were powered through an extension cord that was missing a ground pin. |
|
Citation ID |
01003C |
Citaton Type |
Serious |
Standard Cited |
19260405 G02 IV |
Issuance Date |
2013-03-08 |
Abatement Due Date |
2013-03-23 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-04-02 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: a) West side of building, on or about 2-19-13: Employees were operating a radial arm saw, powered through a cord that exhibited a broken strain relief. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19261053 B04 |
Issuance Date |
2013-03-08 |
Abatement Due Date |
2013-03-23 |
Current Penalty |
1600.0 |
Initial Penalty |
1600.0 |
Final Order |
2013-04-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) East side of building, front, on or about 2-19-13: One employee was using two step ladders that were not being used as designed or for their intended purpose, exposing the employee to a fall hazard of 5 feet. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19030019 C01 |
Issuance Date |
2013-05-31 |
Abatement Due Date |
2013-06-19 |
Current Penalty |
400.0 |
Initial Penalty |
400.0 |
Final Order |
2013-06-25 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated. a) At the jobsite, on or about 4/12/13: The employer did not provide abatement certification for Citation 1, Items 1, 2a, 2b, 3a, 3b, 3c and 4 within 10 calendar days after the abatement date. Abatement certification must be submitted for this item. |
|